UV 400

Ultra Violet Clarifier

Dear Customer,

Congratulations on the purchase of your advanced Tetra

tec

®

Ultra Violet

Water Clarifier. This Ultra Violet Water Clarifier has been carefully designed
to provide a powerful and continuous ultra violet radiation that will destroy
harmful organisms that are exposed to the ultra violet light thus reducing
the possibility of disease problems.

Before installing the unit please read this instruction leaflet
thoroughly and retain it for future reference.

Tetra

tec

®

Ultra Violet Clarifer

A.

Screw Cap

B.

UV-C high performance bulb (Philips

® 

PL-S 5 Watt)

C.

Quartz glass tube

D.

Housing

E.

Inlet/Outlet hose connectors

F.

Quartz Glass Tube O Ring

G.

Rubber sealing rings for hose connectors

The Tetra

tec

®

UV 400 is suitable for use in all 

fresh water aquariums up to 400 liters in capacity

.

How the Tetra

tec

®

UV 400 works

The clarifier works by exposing
microorganisms to very high levels of
ultra violet light as the water contain-
ing them is pumped through the unit.
The UV radiation damages the DNA
and causes it to split into two sepa-
rate helices which results in the cell’s
death.  This will help prevent disease
outbreaks since free-swimming
stages of parasites, bacteria, algae
and fungi will be destroyed. However,
the UV Clarifier will not adversely
affect fish or the beneficial nitrifying
bacteria and algae attached to the fil-
ter bed, gravel and aquarium walls.

Installing your
Tetra

tec

®

UV 400

The Tetra

tec

®

UV 400 is designed for

use with a powerhead, water pump or
canister filter (for correct size of pow-
erhead, water pump or canister filter
please refer to the section on techni-
cal data).

Positioning Your
Tetra

tec

®

UV 400

1.

The Tetra

tec

®

UV 400 is not sub-

mersible and should not be posi-
tioned where there is a likelihood of
the unit falling into the aquarium. The
unit may be mounted on any surface
inside the cabinet or against a wall
(see Illustrations 2 and 3). Insert the
UV-C bulb (B) into the connector (A).
Place the unit in an upright position to
insure correct operation.
Note: Avoid touching the bulb with
bare hands and remove any marks
using a clean cloth.

2.

The inlet and outlet connections

(E) are universal and water can flow
through the unit in any direction.
Choose the inlet connector size of the
UV according to the outlet size of
your powerhead, water pump or can-
ister filter.  Choose the outlet connec-
tor size of the UV according to the
inlet size: make sure that the outlet
size is at least as large as the inlet.
Remove the unused smaller section
of the UV hose connector with a saw
if necessary. Ensure that the rubber-