DESCRIPTION 

This basket strainer is designed to block debris that could potentially clog the 

impeller or volute of pump, causing it to cease moving water. This strainer 
basket can also provide ease in priming your plumbing system during 

startup. Be sure to clean your strainer basket, as well as any skimmer baskets, so water flow is not obstructed and the pump is 
not overworked.

UNPACKING 

When unpacking the basket strainer, inspect carefully for any damage that may have occurred during transit. Check for 

loose, missing and damaged parts. 

 

SPECIFICATIONS 

Capacity: 90 Cubic Inch  

 

BASIC CONSTRUCTION 

 

Body-Glass Filled ABS

 

 

Lid- Lexon 

 

INSTALLATION 

1.

 

Carefully remove the strainer pot assembly from its shipping package.

 

2.

 

Determine the installation location of the strainer pot assembly. Ensure that adequate space is provided for routine maintenance.  

3.

 

Plan carefully the layout of plumbing including cutting pipe to the exact length and ensuring that adapters will be aligned and 
square with the strainer pot assembly and pump. Note that the strainer must be installed so that water flow travels into the upper 

port and out the lower port. Using PVC glue, glue the plumbing in place once you are certain that location is as desired. 

4.

 

Ensure that the upper port gasket is properly positioned between the strainer body and the half union connection

Do not use 

grease or glue to attach as they may contain chemicals that could attack the plastic material

5.

 

Hand tighten the split nut connection onto the strainer and glue the plumbing to the half union fitting with PVC glue. (Make sure to 
hold plumbing firmly for 30 seconds while the glue sets up).  

6.

 

The lower port split nut connection on strainer can be  

7.

 

simply attached directly to most external pump(inlet adapters may be necessary, order as required). Use the gasket provided and 
ensure that it is sitting correctly between either the pump and split nut or inlet adapter and split nut (use Teflon tape with inlet 

adapters). 

8.

 

Hand tighten the split nut connection onto the inlet of the pump.  

9.

 

Turn system on and inspect both port connection(s) for leaks 

 

 

 

 
 

 
 