Page
32
of
35
21
I
Disinfection period
1~30 days
7 days
Adjustable
22
M
EXV open step during defrosting
10 ~ 47
30
Adjustable
23
M
EXV delay time
3 ~ 30
21; N*10 sec.
Adjustable
24
I
Low pressure switch detects temp
-10~25
-5
Adjustable
25
M
Delay detects time of low-pressure switch
after compressor start
2min
~
20min
5min
26
M
Temp to change 4-way change working way
-10
℃
~
10
℃
-2
℃
0
27
M
The time to power on 4-way valve after
compressor starts
0-15min
2min
28
M
Electrical expansive valve action after
compressor off
0-1
0
0=Invalid/1=Valid
29
M
Heat pump setting temperature
0-1
0
0: TS1=real value
1: TS1=manual
30
M
Compensation temperature
-10 ~ 10
℃
0
℃
Adjustable
31
M
Ambient temp sampling period
2-120min
15min
Adjustable
32
I
E-heater control after reach setting temp
0-1
1
Adjustable
33
I
Temp difference to start e-heater
1-10
℃
3
℃
Adjustable
34
M
Max setting temp for e-heater
65-85
℃
75
℃
Adjustable
35
I
ON/OFF
0-1
0
0: (remote on/off signal)
1: (PV function)
Checking parameters: Check the real temperature and expansion valve working process.
Short press button
to entry temp and EXV open step checking.
A
U
Lower tank water temp.
T2
-
9 ~ 99°C
Actual testing value. Error code P1 will be
shown in case of a malfunction
b
U
Upper tank water temp.
T3
-
9 ~ 99°C
Actual testing value. Error code P2 will be
shown in case of a malfunction
C
U
Evaporator coil temp.
T4
-
9 ~ 99°C
Actual testing value. Error code P3 will be
shown in case of a malfunction
d
U
Return gas temp.
T5
-
9 ~ 99°C
Actual testing value. Error code P4 will be
shown in case of a malfunction
E
U
Ambient temp.
T1
-
9 ~ 99°C
Actual testing value. Error code P5 will be
shown in case of a malfunction
F
U
Temp of solar thermal collector
~0 ~ 140
℃
Measured value
if failure
show P6
G
U
Electronic expansion valve step
10 ~ 47 step
N*10 step
H
U
Tank water setting temp. real value
TS1