Instructions for use and maintenance

EN

III. 

DESCRIPTION AND PRINCIPLE OF WORK

The appliance is designed to operate in regions where the 

water hardness is not more than 10°dH. In case that it is 

installed in a region where the water is harder it is possible that 

limestone precipitation accumulate very fast. This can cause a 

specific noise during heating, as well as fast damaging of the 

electrical part. For regions with harder water yearly cleaning of 

the limestone precipitation in the appliance is recommended, 

as well as usage of not more than 2 kW of heating power.
The appliance consists of a body, flange at the bottom side /

for water heaters intended for vertical mounting/ or at the 

sides /for water heaters intended for horizontal mounting/, 

protective plastic panel safety-return valve.

1. 

The body consists of a steel reservoir (water tank) 

and housing (outer shell) with thermal insulation placed 

in-between made of ecologically clean high density 

polyurethane foam, and two pipes with thread G ½ ‘’ for cold 

water supply (marked by a blue ring) and hot water outlet 

pipe (marked by a red ring).

The inner tank may be of two types depending on the model:

 •

Made of steel protected form corrosion by a special glass-

ceramics coating 

 •

Made of stainless steel

The vertical water heaters may be outfitted with a built in 

heat exchange unit (serpentine tube). The heat exchenger’s 

entrance and exit are located at the sides and represent pipes 

with thread G ¾ ‘’. 

2. 

  The flange is outfitted with: electric heater and 

thermostat. The water heaters with glass-ceramics coating are 

outfitted with a magnesium protector. 

The electric heater is used for heating the water in the tank 

and is managed by the thermostat, which automatically 

maintains the set temperature.

The thermostat has a built in overheating safety device, which 

switches of power to the heater when the water temperature 

reaches excessive values. 

3. 

  The safety-return valve prevents the appliance’s complete 

emptying in the event the cold water supply is interrupted. 

The valve protects the appliance from pressure increases 

higher than the allowed value during heating (! pressure 

increases upon an increase of temperature), via release of 

excess pressure during the drainage opening.

The safety-return valve cannot protect the appliance in the 

event of water mains pressure in excess of the acceptable 

pressure stated for the appliance.

IV. 

MOUNTING AND SWITCHING ON

Attention! Improper installation and connection of the 

appliance may make it hazardous for the health and life of 

consumers. It may cause grievous and permanent consequences, 

including but not limited to physical injuries and/or death. Improper 

installation and connection of the appliance may also lead to 

damage to the consumers’ property /damage and/ or destruction/, 

or to that of third persons, as a result of, but not limited to flooding, 

explosion and/or fire. Installation, connection to the main water and 

power supply, and putting into operation must be carried out by 

certified electricians and technical personnel certified in installation 

of this category of appliances, who have obtained their license in the 

state where the installation and commissioning of the appliance are 

carried out, and in compliance with its local legislation.

Notice

: The installation of the unit is at the buyer’s 

expense.

1. 

Mounting

 

We recommend the mounting of the device at close proximity 

to locations where hot water is used, in order to reduce 

heat losses during transportation. In the event the device is 

mounted in a bathroom, the selected location must exclude 

the possibility of water spray contact from the showerhead or 

portable showerhead attachment.

The appliance is affixed to a wall via the mounting brackets 

attached to the unit’s body (if the brackets are not attached to 

the unit’s body, they must be affixed in place via the provided 

bolts). Two hooks are used for suspending the appliance (min. 

Ø 10 mm) set firmly in the wall (not included in the mounting 

set). The mounting bracket’s construction designed for water 

heaters intended for vertical mounting is universal and allows 

a distance between the hooks of 220 to 310 mm (fig. 1a).  

In order to prevent injury to user and third persons in the 

event of faults in the system for providing hot water, the 

appliance must be mounted in premises outfitted with floor hydro 

insulation and plumbing drainage. Don’t place objects, which are 

not waterproof under the appliance under any circumstances. In 

the event of mounting the appliance in premises not outfitted with 

floor hydro insulation, a protective tub with a plumbing drainage 

must be placed under the appliance.

Notice

: the set does not include a protective tub and the 

user must select the same.

2. 

Water heater connection to the pipe network.

Fig. 4:  Where: A ≈4m; 1 - Inlet pipe; 2 - Safety valve; 3 - reducing 

valve (for water main pressure > 0,6 MPa); 4 - Stop valve; 5 - 

Funnel connected to the sewer network; 6 – Hose; 7 - Drain 

water tap.

Upon connecting the water heater to the water mains you must 

consider the indicative color markings /rings/ affixed to the 

pipes: blue for cold /incoming/ water, red for hot /outgoing/ 

water.

The mounting of the safety return-valve supplied with the water 

heater is obligatory. The safety return-valve must be mounted 

on the cold water supply pipe, in observance of the direction 

arrow stamped on its body, indicating the incoming water’s 

direction. Additional stopcocks must not be mounted between 

the safety return-valve and the water heater.

Exception

: If the local regulations (norms) require the usage 

of another protection valve or mechanism (in accordance with 

EN 1487 or EN 1489), then it must be bought additionally. 

For mechanisms operating in accordance with EN 1487 the 

announced operational pressure must be no more than 0.7 

MPa. For other protection valves, the pressure at which they 

are calibrated must be 0.1 MPa lower than the one marked on 

the appliance’s sign. In these cases the safety valve which the 

appliance is supplied with should not be used.

The presence of other /old/ safety return-valves may lead 

to a breakdown of your appliance and they must be 

removed.

Other type of stopping armature is not allowed between 

the protection return valve (the protective device) and the 

appliance.

The attaching of the safety return-valve to threads longer than 

10 mm is not allowed, otherwise this may damage the valve 

and poses danger for your appliance.

With appliances for vertical assembly, the safety valve has 

to be connected to the ingoing pipe with the safety plastic 

panel of the appliance being taken off. 

The safety valve and the pipe between the valve and the water 

heater must be protected from freezing. During hose draining 

- its free end must be always open to the atmosphere (not to be 

immersed). Make sure that the hose is also protected from freezing.

Содержание GCH 503520 B12 TSR

Страница 1: ...V ZT ROL 11 18 Szerel si s kezel si tmutat www tesy com is a registered trade mark of Tesy ltd GCV 303512 B11 TSR GCV 504420 B11 TSR GCV 804420 B11 TSR GCV 1004420 B11 TSR GCV 1204420 B11 TSR GCV 1504...

Страница 2: ......

Страница 3: ...nofthiscategoryofappliances whohave obtainedtheirlicenseinthestatewheretheinstallationandcommissioningoftheappliancearecarriedout andin compliancewithitslocallegislation Allalterationsandmodifications...

Страница 4: ...ucet must be opened The water tap 7 fig 4 must be opened to drain the water from water tank If there is no such tap build in the pipe line than the water can be drain directly from inlet pipe of water...

Страница 5: ...05397 B GCV 5044 20 B11 TSR TIN 305398 C GCV 804420 B11 TSR TIN 305399 D GCV 1004420 B11 TSR TIN 305400 E GCV 1204420 B11 TSR TIN 305401 F GCV 1504420 B11 TSR TIN 305402 G GCH 503520 B12 TSR TIN 30604...

Страница 6: ...Load profile Sound power level Daily fuel consumption Emission of nitrogen oxides Weekly fuel consumption with smart control Weekly electricity consumption with smart control Weekly fuel consumption w...

Страница 7: ...04420 B11 TSR TIN 300469 B GCVS 1004420 B11 TSR TIN 305298 table II c d e Model Energy efficiency class Standing loss Storage volume S V W l A C 64 93 B C 67 98 Product Information in accordance with...

Страница 8: ...installation of the unit is at the buyer s expense 1 Mounting We recommend the mounting of the device at close proximity to locations where hot water is used in order to reduce heat losses during tra...

Страница 9: ...mm cable 3 x 2 5 mm for power 3700W The electrical circuit supplying the appliance must have an in built device ensuring the splitting of all terminal poles under conditions of super voltage of categ...

Страница 10: ...s needed or in case of repairs to the system of the heat exchanger coil The proper way of connecting the appliance to the electric network and how to work with it has been specified in the previous pa...

Страница 11: ...l lt is Szint n a vagyonuk k raihoz is vezethet ez megk rosod sa s vagy megsimisit se gy ahogy harmadik szem lyeknek is bele rtve de nem csak az rad st l robban st l t zt l okozot A beszerel st a v zv...

Страница 12: ...seket kell tenni a kifolyt mennyis g elt vol t s ra vagy sszegy jt s re a s r l sek eker l se rdek ben 7 Ha el fordul olyan lehet s g hogy a h m rsekl t a helyis gben lecs kken O f k alatt akkor a v z...

Страница 13: ...01 F GCV 1504420 B11 TSR TIN 305402 G GCH 503520 B12 TSR TIN 306042 H GCH 804420 B12 TSR TIN 306043 1 t bl zatot c d e f g h i j k l T pus V zmeleg t s N vleges terhel si profil V zmeleg t s Energiaos...

Страница 14: ...senergia fogyaszt s intelligens smart vez rl ssel Heti t zel anyag fogyaszt s intelligens vez rl s n lk l Heti villamosenergia fogyaszt s intelligens vez rl s n lk l Ezenk v l a 3XS az XXS vagy az XS...

Страница 15: ...N 300469 B GCVS 1004420 B11 TSR TIN 305298 3 t bl zatot c d e T pus V zmeleg t s Energiaoszt ly H t rol si vesztes g Tart ly t rfogata S V W l A C 64 93 B C 67 98 Term kismertet adatlap 814 2013 T pus...

Страница 16: ...ter let nszerezt kmega szakk pes t s ket aholleszv gezveak sz l ktelepit se s zembe helyez se sazel r soknak sszab lyoknakmegfelel en Megjegyz s A k sz l k felszerel se a vev k lts g re t rt nik 1 Sze...

Страница 17: ...lektromos h l zat f zisvezet j hez L A szigetel s k k sz n zsin rja az elektromos h l zat nullavezet j hez N A szigetel s s rga z ld sz n zsin rja az elektromos h l zat v d vezet j hez 3 3 T pk bel n...

Страница 18: ...v laszt s a rendszer tervez s n l t rt nik pl k ls termoszt t amely m ri a h m rs kletet a v ztart lyban s m k dteti egy keringet szivatty t vagy egy m gneses szelepet A h cser l s v zmeleg t kn l a f...

Страница 19: ...TSR 440 1150 1057 467 182 GCV 1504420 B11 TSR 440 1315 1222 467 182 min 100 mm min 100 mm min 100 mm min 700 mm min 300 mm GCV E H H1 100 125 max 310 mm min 220 mm max max min min G GCV GCV B D 1 Type...

Страница 20: ...B11 TSR 440 985 892 480 242 467 182 1 GCVSL GCVS 150 E H1 H G B D 100 125 G G G L F max 310 mm min 220 mm max max min min min 100 mm min 700 mm min 100 mm min 700 mm min 300 mm GCV x S Type S m2 V L...

Страница 21: ...2 1 2 3 1 2 3 appx 40 C appx 25 C appx C 70 appx C 60 appx C 55 e e Anti freeze e e appx 40 C appx C 70 appx C 60 Anti freeze e KL L N S S TR TS TR IL IL IL IL R R TS KL L N TR IL IL TS INOX...

Страница 22: ...4 H O 2 H O 2 A 3...

Страница 23: ......

Страница 24: ...205881_003 TESY Ltd Shumen 9700 48 Blvd Madara PHONE 359 54 859 129 office tesy com...

Отзывы: