TeSuCo Oxyturbo Nitrogen 6000 Скачать руководство пользователя страница 4

4

  CAUTIONS 

 

 Before opening the cylinder valve (1), check carefully that the regulator is 
completely closed (turn the pressure adjusting screw (6) anticlockwise).

3.2 How To Regulate Pressure

  

To increase pressure: slowly turn the regulator pressure adjusting screw (6) clockwise.

  

To decrease pressure: slowly turn the regulator pressure adjusting screw (6) anticlockwise.

  CAUTIONS

 

  

Using the pressure adjusting screw (6) it is possible to compensate an eventual 
pressure drop.

 

  

Outlet pressure must not be regulated higher than the pressure you need to use 
when flowing.

 

  

Outlet pressure must not be regulated higher than the red mark on the low  
pressure gauge (5).

3.3 Closing

  Close the cylinder valve (1).

  Release the gas until the regulator gauges indicate "zero".

  Turn the pressure adjusting screw (6) anticlockwise till it is completely closed.

3. INSTRUCTIONS FOR USE

  

The pressure regulator must be treated as a precision instrument.

   When the pressure regulator is not to be used for long periods, store it in its wrapping or 

in its box , to prevent contact with dust, oil and other sources of dirt.

   Do not carry out maintenance or repairs, other than the following.

  Use only original OxyTurbo spare parts and accessories.

  Spare parts are available also from your retailer.

   In case of failures which cannot be repaired following these instructions, take your 

pressure regulator back to the retailer.

4. STORAGE

5. MAINTENANCE

Содержание Oxyturbo Nitrogen 6000

Страница 1: ...1 Operating Instructions Nitrogen 6000 Regulator HVAC R High Flow www tesuco com au QUALITY GAS EQUIPMENT ...

Страница 2: ... cylinder into the pressure needed to use for the application The pressure regulator has been designed so as to be used only and exclusively with the type of gas and at the pressures which are shown by the marking To try and use the pressure regulator with types of gases and pressures other than those indicated can be dangerous 1 Cylinder valve 2 Inlet connection O ring seal 3 Inlet connection nut...

Страница 3: ...ront of the cylinder valve 1 Position the pressure regulator with the gauges the right way up Screw the inlet connection 3 tightly to the cylinder valve by hand or by using a spanner 3 1 Opening Slowly open the cylinder valve 1 The high pressure gauge 4 will show you the cylinder pressure Opening the cylinder valve too quickly may make gauges malfunction Open the pressure adjusting screw 6 very sl...

Страница 4: ...er than the red mark on the low pressure gauge 5 3 3 Closing Close the cylinder valve 1 Release the gas until the regulator gauges indicate zero Turn the pressure adjusting screw 6 anticlockwise till it is completely closed 3 INSTRUCTIONS FOR USE The pressure regulator must be treated as a precision instrument When the pressure regulator is not to be used for long periods store it in its wrapping ...

Страница 5: ...or lost The pressure regulator or any of its parts gauge inlet connection outlet connection are damaged or dirty oily etc There are any leaky connections The relief valve adjustment has been modified or the valve leaks 5 2 Relief Valve For safety reasons the pressure regulator is equipped with an excess pressure valve In case of malfunctioning this valve allows the excess gas pressure to vent CAUT...

Страница 6: ...on error Release the control knob tighten the connections and re check Apply pressure again if leak persists repair or replace Increase in output pressure when not flowing Leak through the regulator seat valve Replace the encapsulated seat Unstable output pressure Flow rate to high Check the flow of the regulator matches the requirement Vibrations Flow rate to high Limit the flow with the control ...

Страница 7: ...7 Note Some of the details in the illustration may differ from those of the appliance supplied This company reserves the right to modify the product without prior warning ...

Страница 8: ...he operator in the safe use of a Tesuco Nitrogen 6000 Regulator However the ultimate responsibility for the safe use of this and any attached equipment lies solely with the operator including any requirements of associated Australian Standards OI_RC1SNI60C_V01 ...

Отзывы: