7 Performing the measurement
27
assigned to a temperature value is fixed (important for visual image
comparisons).
Scaling influences the way the infrared image is shown on the display
but does not affect the recorded measuring values.
With ScaleAssist, a standardized scale is set depending on the inside
and outside temperature.
Setting automatic scaling
1
- Select the Scale function.
2
- Move the joystick up/down until Auto is selected.
3
- Select
✔
and press OK.
Automatic scaling is activated.
A
is displayed bottom right.
Setting manual scaling
The lower limit value, the temperature range (upper and lower limit value
simultaneously) and the upper limit value can be set.
1
- Select the
Scale
function.
2
- Press
OK
.
3
- In the mode menu, move the
joystick
up/down until
Manual
is
selected.
4
- Move the
joystick
to the right, select
Min. Temp.
(lower limit value).
- Move the
joystick
up/down to set the values.
5
- Move the
joystick
to the right, select
Max. Temp.
(upper limit value).
- Move the
joystick
up/down to set the value.
5.1
- If necessary, Select
X
and press
OK
to go back to the mode menu.
6
- Select
✔
and press
OK
.
Manual scaling is activated.
M
is displayed bottom right.
Setting ScaleAssist
The ScaleAssist function calculates a display-neutral scale depending on the
inside and outside temperature. This scale graduation can be used to detect
structural defects in buildings.