Using the product

15

Using the product

 To ensure correct readings:

    ·  Position instrument so that flow impacts at the rear.

·  Keep temperature and humidity sources which may falsify the 

measurement (e.g. hands) away from the sensor.

ã

 Switching the instrument on:

> Press  .

-  Measuring mode is opened.

ã

 Switching the display light on:

3

  The instrument is switched on.

> Press  .

-  The display light goes out automatically if no key is 

pressed for 10 seconds.

ã

 Changing the parameter:

 The parameter in the top display line can be changed. The 

bottom display line always shows the  temperature.

Adjustable parameters

· Velocity
· Humidity
·  Wind chill temperature (

): perceived temperature (only deviates from 

ambient temperature at temperatures <10°C / <50°F and wind speeds 

>1.34m/s / >264 fpm)

> Press   several times until the desired parameter appears.

ã

 Changing the display view:

Adjustable views

·  Current reading
·  Hold: Readings are held.
·  Max: Maximum values since the instrument was last switched on or last reset.
·  Min: Minimum values since the instrument was last switched on or last reset.
·  Hold Avg: Timed mean value calculation, see below.

> Press   several times until the desired view appears.

ã

 Timed mean value calculation for flow:

1

 Press   several times, until 

Hold 

and 

Avg

 appear in the 

display. The last result of mean value calculation is 
displayed. 

2

 Hold   down until 

- - - - 

appears. Releasing   starts 

mean value calculation automatically, the current readings 
are displayed.

de

en

fr

es

it

pt

sv

nl

??

??

Содержание 410-2

Страница 1: ...Notizen 10 ...

Страница 2: ...ing the display light on for 10s Instrument on press Select display size Instrument on select with Velocity humidity wind chill temperature Select display mode Instrument on select with Current reading Hold Readings are held Max Maximum values Min Minimum values Hold Avg Timed mean value calculation see below Timed mean value calculation for flow Press several times until Hold and Avg appear Hold ...

Страница 3: ...s intended purpose and within the parameters specified in the technical data Do not use force Never store the product together with solvents acids or other aggressive substances Only carry out the maintenance and repair work that is described in the documentation Follow the prescribed steps when doing so Use only OEM spare parts from Testo Do not use the device in a polluted environment heavily du...

Страница 4: ... 4000 fpm 10 50 C 14 122 F 0 100 rH Resolutions 0 1 m s 1 fpm 0 1 C 0 1 F 0 1 rH Accuracies Nominal temperatue 22 C 1 Digit 0 2 m s 2 of reading 40 fpm 2 of reading 0 5 C 0 9 F 2 5 rH 5 95 rH Long term stability 1 rF year Measuring rate 0 5 s humidity 1s Further instrument data Protection class IP10 Ambient conditions 10 50 C 14 122 F Storage transport conditions 40 70 C 40 158 F Temperature coeff...

Страница 5: ...on ã Basic settings configuration mode Adjustable functions Unit of temperature C F Unit of humidity td dew point WB wet bulb Unit of velocity m s km h fpm mph kts Beau Auto off function OFF ON instrument switches off automatically if no key is pressed for 10 minutes 1 When switching the instrument on press and hold until and appear on the display configuration mode The adjustable function is disp...

Страница 6: ...emperature perceived temperature only deviates from ambient temperature at temperatures 10 C 50 F and wind speeds 1 34m s 264 fpm Press several times until the desired parameter appears ã Changing the display view Adjustable views Current reading Hold Readings are held Max Maximum values since the instrument was last switched on or last reset Min Minimum values since the instrument was last switch...

Страница 7: ...ulation hold down 5 End mean value calculation press briefly ã Resetting Max Min values 1 Press several times until the desired view appears 2 Press and hold until appears 3 Repeat steps 1 and 2 for all values that are to be reset ã Switching the instrument off Press and hold until the display goes out ...

Отзывы: