background image

testo 316 - 1

Instruction manual

Monitoring instrument 

to detect gas leaks. 

The testo 316-1 detects even the smallest leaks of combustible gases in pipelines, flanges and

screw connections etc. The bendable probe stem has no problem reaching even inaccessible

points. Its wide range of applications makes the gas leak monitoring instrument indispensable for

every professional.

Do not measure on live parts.

This Instrument is not designed to operate while wet or in an environment of

condensing humidity (> 95 %RH).

Observe maximum storage and transport temperature and maximum operation temperature 

(e.g. protect measuring instrument from direct sunlight)!

Do not use 

testo 316-1

in enclosed rooms where gases have gathered to form an explosive

mixture.

Ensure that the gas concentration does not exceed the lower explosion limit of gas mixtures by

20%.

The alarm limits are adjusted downward when the sensitivity is set in a gas environment.

Always carry out a function test prior to gas leak detection.

Set sensitivity of sensor in fresh air. 

Switching on

- Turn control button

-  Warm-up phase of sensor begins 

- LED is red

- Alarm signal sounds

-  Warm-up phase max 30 seconds

- LED is green

- Alarm signal off

Ready to operate

- No alarm signal

-  LED is green

Setting sensitivity in fresh air

- Turn control button to the right until the sound

signal is heard

-  Turn the control button to the left until the 

sound signal stops.

Detecting leaks

- Sound signal when gas is escaping

- Signal becomes quicker as concentration incre-

ases

-

Alarm > 200 - 10000 ppm

- LED changes from green to yellow

- Warning sound

-

Alarm > 10000 ppm

- LED changes from yellow to red

- Warning sound

Function test

- Expose sensor to a combustible gas e.g. from

a

know leak point in the pipeline or from a butane

(gas) lighter, for a period nor exceeding 10 sec.

- If the sensor does not react (no alarm), the

instrument should be considered as defective

and must not be used. Return the unit imme-

diatly to the nearest Test service point for

repair.

Green LED

Switching on

Ready to operate

Setting sensitivity

Measuring

Batteriewechsel

Technische Daten

Abgleich-Zertifikat

Bestelldaten

Bestell-Nr.

Messbereich:

0...10.000 ppm (1 Vol%) CH4

1. Alarmschwelle:

spätestens bei 200 ppm LED leuchtet gelb

2. Alarmschwelle:

spätestens bei 10.000 ppm LED leuchtet rot

Batteriestandzeit:

> 5 h bei Typ Alkali-Mangan IEC 6LR61

Betriebstemperatur:

4...45 °C

Lager-/Transport-

temperatur:

-20...+50 °C

Abmessungen:

90 x 57 x 42 mm

Gewicht:

ca. 300 g

Garantie:

2 Jahre

testo 316-1, Gasleck-Überwachungsgerät inkl. Bedienungsanleitung und Batterie 

0632.0316 

Bereitschaftstasche

0516.0182

TopSafe, unverwüstliche Schutzhülle inkl. Aufsteller

0516.0189

Kunststoff-Koffer, für Transport und Aufbewahrung von Messgerät und Zubehör

0516.3120

Serien-Nr.

Optischer Signalgeber

o

ok

Serial no.

Optical emitter
Akustischer Signalgeber

o

ok

Accustic emitter

Einstellung der Alarmschwellen

Setting alarm thresholds

Sollwert/Reference

Geprüft bei/Tested at

Alarm 1

200 ppm

________ ppm

o

ok

Alarm 2

8800 ppm

________ ppm

o

ok

Low Batt Signal

Wenn während des Einsatzes die LED ausschaltet und ein Signalton im Sekundentakt hörbar ist,

Batterie innerhalb von 15 Minuten wechseln.  

- Gehäuseschraube öffnen (Rückseite). 

- 9 V Blockbatterie einlegen. 

Polung beachten!

- Gehäuse schließen.

Entsorgungshinweis:

Entladene Batterien in Sammelbox werfen. Um Kurzschlüssen vorzubeugen,

Batterien einzeln in Plastikbeutel geben!

Messgerät konform zu:

EN 50 082 Teil 1

EN 50 081 Teil 1

Отзывы: