8 Tips and assistance 

 

 

19

 

Question 

Possible causes/solutions 

 and   flash, 

E401

 

lights up  

Rechargeable battery is empty, 

instrument will soon switch off 

automatically. 
>  Connect the mains unit (the warning 

can be deleted with 

[Hold/Max/Min]

). 

 and   flash 

Recharging the battery is impossible: 
>  Contact your dealer or the Testo 

Customer Service. 

Can the battery be 

replaced? 

The battery cannot be replaced. 
>  Contact your dealer or the Testo 

Customer Service. 

Can the battery be 

charged via the USB 

port of a laptop or 

PC? 

The battery cannot be charged. 

Can Bluetooth

® 

be 

retrofitted? 

Bluetooth

®

 functionality cannot be 

retrofitted. 

Can humidity, 

temperature and dew 

point measurements 

be carried out? 

Humidity, temperature and dew point 

measurements are possible with the 

temperature/humidity module 

(accessory). 

The display is 

illuminated also after 

the testo   315 - 3 is 

switched off 

The display illumination goes out as 

soon as the instrument has shut down. 

While the display is illuminated, the 

instrument cannot be switched on. 

The CO

2

 measuring 

value is displayed as 

0000

 

The current measuring value is over 

10,000 ppm. 

The CO2 reading is 

implausible. 

The gas opening on the back of the 

instrument might be covered. This 

means that a correct CO2 

measurement is not possible. 

 

If we could not answer your question or the solutions given during 

troubleshooting did not help: please contact your dealer or Testo 

Customer Service. Contact data see back of this document or 

websit

www.testo.com/service-contact

. 

 

Содержание 315-3

Страница 1: ...testo 315 3 CO CO2 measuring instrument Instruction manual...

Страница 2: ...2...

Страница 3: ...er instrument data 7 3 2 4 Bluetooth module option 7 4 Product description 9 4 1 Overview 9 4 1 1 Control elements and connections 9 4 1 2 Display 12 4 2 Basic properties 13 5 First steps 13 6 Using t...

Страница 4: ...writing standards Represen tation Explanation Note Basic or further information 1 2 Action more steps the sequence must be followed Action a step or an optional step Result of an action Menu Elements...

Страница 5: ...mperatures For products with Bluetooth optional Changes or modifications that have been made without the explicit consent of the responsible approval authority may cause the retraction of the type app...

Страница 6: ...ndustry The Bluetooth option may only be operated in countries in which it is type approved 3 2 Technical data 3 2 1 Measurement ranges and resolution Measurement parameter Measuring range Resolution...

Страница 7: ...to 95 RH Weight incl holster Approx 382 g Housing material ABS Dimensions L x W x H 190 x 65 x 40 mm Protection class IP 40 acc to EN 60529 Operating time Min 10 h measuring time at 20 C 68 F mains o...

Страница 8: ...inland FI France FR Greece GR Ireland IE Italy IT Latvia LV Lithuania LT Luxembourg LU Malta MT Netherlands NL Austria AT Poland PL Portugal PT Romania RO Sweden SE Slovakia SK Slovenia SI Spain ES Cz...

Страница 9: ...4 1 Overview 4 1 1 Control elements and connections 1 Connection for temperature humidity module optional 2 IR interface record printer 3 CO sensor module 4 CO2 sensor module back 5 Display 6 Keyboar...

Страница 10: ...figuration mode Confirms entry next setting Long Reading display current value Opens configuration mode Reading display maximum value minimum value hold value Resets maximum value minimum value hold v...

Страница 11: ...n mode Changes option increases value Long Reading display Sets zero point deletes zero point Configuration mode Increases value quickly Short Reading display Prints data Configuration mode Changes op...

Страница 12: ...abled Lights up information Flashes error message Differential measurement calibration Flashes adjust CO2 sensor in fresh air CO2 sensor should be adjusted in fresh air after 120 operating hours 2 Mea...

Страница 13: ...45 C 32 to 113 F 5 First steps Switching on Connect the humidity temperature module 0636 9725 before switching the instrument on option 1 Switch the instrument on press briefly All segments of the di...

Страница 14: ...cancel the function press briefly until the display changes Adjustable functions Ensure correct settings all settings are transferred immediately There is no Cancel function Settings and display of t...

Страница 15: ...e carried out on busy roads or in closed rooms Ensure that before and during the calibration adjustment no exhaled air reaches the instrument Before completing the adjustment the instrument should be...

Страница 16: ...Hold Max Min testo 315 3 is in measurement view The measuring values for Hold Max Min can be called up for CO and CO2 Temperature and humidity if temperature and humidity module is connected Dew poin...

Страница 17: ...en carried out Switch on data transfer press and hold down lights up Data is transferred Please refer to the operating instructions for the relevant testo measuring instrument 7 Maintaining the produc...

Страница 18: ...and E290 lights up The current CO2 measuring value is too high for an adjustment Acknowledge the error message with Hold Max Min and carry out the adjustment again in fresh air CO2 measuring value 65...

Страница 19: ...ew point measurements be carried out Humidity temperature and dew point measurements are possible with the temperature humidity module accessory The display is illuminated also after the testo 315 3 i...

Страница 20: ...ts Description Article no testo 315 3 without Bluetooth incl micro USB mains unit cable USB A USB micro B 0632 3153 testo 315 3 with Bluetooth incl micro USB mains unit cable USB A USB micro B 0632 31...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...0970 3153 en 04...

Отзывы: