Using the product
14
not be pressurised during zeroing!
To help position the flue gas probe in the centre of the flow (area of the
highest flue gas temperature), the flue gas temperature measured is
shown graphically.
Do not measure for longer than 5 minutes, as the readings may fall
outside of the tolerances due to a possible drift of the pressure sensor.
S
Sm
mookkee//O
Oiilldd function: Only available if a liquid fuel has been activated.
D
Diiffff--tteem
mpp.. function: The differential temperature set (0554 1208)
must be connected. The ambient air sensor must be unplugged (located
bottom left of unit) before connecting the T1 sensor. Be aware that the
connector is a firm fit, when disconnecting.
The differential temperature is calculated from T1 - T2.
D
Diiffff--pprreessss function: The gas pressure set (0554 1203) must be connected.
The pressure sensors are zeroed when the D
Diiffff..--pprreessss function is started
(length of time: 5 s). The measuring instrument must not be pressurised
during zeroing!
Do not measure for longer than 5 min, as a drift of the pressure sensor
may result in readings outside the tolerance limits.
A
Am
mbbiieenntt C
CO
O: When the measuring cells are first started after the
measuring instrument is switched on, they are zeroed (length of time: 30
s). Exception: The FFlluuee ggaass function has already been called up.
Any connected probe must be in the open air during the zeroing phase!
The measurement values from the functions D
Drraauugghhtt,, D
Diiffff..--tteem
mpp..,
D
Diiffff..--pprreessss and S
Sm
mookkee//O
Oiilldd are transferred to the the central measurement
menu FFlluuee ggaass and must therefore be carried out before the flue gas
measurement.
FFlluuee ggaass function:
11
Start the measurement with the S
Sttaarrtt function key.
- The current readings are displayed.
Ensure flue is at normal operating temperature and the readings are steady,
before accepting flue gas measurements.
22
Stop the measurement with the S
Sttoopp function key.
LLeett bbyy and ttiigghhttnneessss function:
- The time value is blinking.
11
Set measuring time (from 1 to 15 minutes) using / and confirm with
the S
Sttaarrtt function key.
- The message ZZeerrooiinngg w
wiitthhoouutt ooppeerraattiinngg pprreessssuurree is displayed.
- After zeroing, the message A
Attttaacchh ttoo tthhee ssyysstteem
m aanndd ssttaarrtt is displayed.
A
Accttiivvaattiinngg m
meeaassuurriinngg ffuunnccttiioonn::
11
Press .
22
Select M
Meeaassuurree using / and confirm entry with the O
OK
K function key.
33
Select the required measuring function using / and confirm entry with
the O
OK
K function key.
FFuunnccttiioonnss
11.. FFlluuee ggaass: flue gas measurement with flue gas probe and central measurement menu for
displaying/printing out all readings obtained from the various measuring functions.
22.. LLeett bbyy: timed measurement of differential pressure with differential pressure set
(accessory).
33.. ttiigghhttnneessss: timed measurement of differential pressure with differential pressure set
(accessory).
44.. D
Drraauugghhtt: flue draught measurement with flue gas probe and differential pressure
measurement with gas pressure set (accessory).
55.. S
Sm
mookkee//O
Oiilldd: enter smoke number/oil derivative (only available if a liquid fuel has been
activated).
66.. H
HC
CTT: enter the heat carrier temperature.
77.. D
Diiffff--pprreessss: measurement of differential pressure with differential pressure set (accessory).
88.. D
Diiffff--tteem
mpp: measurement of differential temperature with differential temperature set
(accessory).
99.. A
Am
mbbiieenntt C
CO
O: timed measurement of ambient CO with flue gas probe.
FFlluuee ggaass function: When the measuring cells are first called up after the
measuring instrument is switched on, they are zeroed (length of time: 30 s).
Exception: the A
Am
mbbiieenntt C
CO
O function has already been started.
During the zeroing phase, the fuel can be selected. Any connected probe
must be in the open air during the zeroing phase!
Performing the measurement
M
Meeaassuurriinngg::
The steps described in the chapter Preparing for measurement have
been completed.
LLeett bbyy and ttiigghhttnneessss function: The Diff Press Kit (0554 1203) must be
connected.
W
Waarrnniinngg!! Risk of explosion due to dangerous mixture of gases!
Make sure there are no leaks between the sampling point and
the measuring instrument.
Do not smoke or use naked flames during measurement.
D
Drraauugghhtt function: The pressure sensors are zeroed when the D
Drraauugghhtt
function is started (length of time: 5 s). The measuring instrument must