Definitions

 

 

Measurement Category II (CAT II)  
refers to local-level electrical distribution, such as that provided by a standard wall 
outlet or plug-connected equipment. Examples of CAT II measurements would be 
household appliances, portable tools, and similar modules. 

 

 

Measurement Category III (CAT III)

  

refers to measurements on hard-wired equipment in fixed installations, distribution 
boards, and circuit breakers that form part of a building wiring installation. Other 
examples are wiring, including cables, bus bars, junction boxes, switches, socket 
outlets in the fixed installation, and stationary motors with permanent connections to 
fixed installations 

  

Pollution Degree 2

  

refers to an operation environment where normally only dry, non-conductive pollution 
occurs. Temporary conductivity caused by condensation can be expected. 

  

Working CAT rating is equal to that of the lowest rated element 

within the test set-up.

 

 
 

Compliance Statements

 

 

EC Declaration of Conformity

 

 

The product conforms to the applicable European Union requirements per  
IEC 61010-031:2015 Safety requirements

 

 

for electrical equipment for measurement, control and laboratory use.  
Part 31: Safety requirements for hand-held probe assemblies for electrical 
measurement and test. 

 

EU RoHS Compliance

 

 

The probe and accessories conform to the 2011/65/EU RoHS2 Directive.

 

 

Disposal of Old Electrical & Electronic Equipment

 

 

(Applicable in the European Union and other European countries with 
separate collection systems). This product is subject to Directive 
2012/19/EU of the European Parliament and the Council of the European 
Union on waste electrical and electronic equipment (WEEE), and in 
jurisdictions adopting that Directive, is marked as being put on the market 
after August 13, 2005, and should not be disposed of as unsorted 
municipal waste. Please utilize your local WEEE collection facilities in the 
disposition of this product and

 

 

otherwise observe all applicable requirements.

 

 

This probe is in compliance with IEC 61010-031:2015 CAT III, Pollution Degree 2. 

Содержание TT-SI 7002

Страница 1: ...INSTRUCTION MANUAL TT SI 7002 25MHz active differential probe x20 x50 x200 ...

Страница 2: ......

Страница 3: ...midity dampness or other environmental conditions that might affect safety Do Not Remove the Probe s Casing Removal of the probe s casing may expose you to electric shock If necessary disconnect the inputs and outputs of the probe before opening the case Hazardous Contact To avoid injury remove jewelry such as rings watches and other metallic objects Do not touch exposed connections and components...

Страница 4: ...rking voltage ranges See specifications on page 7 Use Proper Power Source Do not operate this probe from a power source that applies more than the voltage specified Must be Grounded This probe is grounded by the shell of the BNC connector through the grounding conductor of the power cord of the measurement instrument Before making connections to the input leads of this probe ensure that the output...

Страница 5: ...hin the test set up Compliance Statements EC Declaration of Conformity The product conforms to the applicable European Union requirements per IEC 61010 031 2015 Safety requirements for electrical equipment for measurement control and laboratory use Part 31 Safety requirements for hand held probe assemblies for electrical measurement and test EU RoHS Compliance The probe and accessories conform to ...

Страница 6: ...ndicator LED Initial Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt An initial physical inspection should be made to ensure that no damage has been sustained during shipment After the inspection verify the contents of the shipment Delivery Content Differential probe TT SI 7002 2 x Grabber black red TT SI GR2 2 x test leads with insulated 4 mm ...

Страница 7: ...o to x50 and for voltages up to 700 V set the attenuation ratio to x200 4 The power indicator LED should turn on 5 Plug the supplied grips onto the test leads and connect the circuit under test Vertical Scale on Oscilloscope The actual vertical scale of the oscilloscope is equal to the attenuation factor multiplied by the range of vertical scale selected on the oscilloscope For example with the pr...

Страница 8: ... 6 Over Range Indicator Red Attenuation Selector Switch Power Indicator Red Probe Input 2 x 4mm Plug External Power Supply Probe Output BNC Connector 3 Product Overview Included Accessories TT SI NT7 TT SI TL7 TT SI GR2 TT SI BN7 ...

Страница 9: ...tage each side to ground 600 Vrms Input Impedance differential 4 MOhm 1 2 pF Input Impedance each side to ground 2 MOhm 2 3 pF Output Voltage Swing 8 V using 1 MΩ oscilloscope input Offset typical 5 mV Noise typical 2 mVrms Source Impedance 50 Ohm Power Supply 9 V power adapter included Weight 250 g Dimensions 195 x 55 x 30 mm BNC cable length 100 cm Input lead length 55 cm each Operation Tempearu...

Страница 10: ...I 7002 Derating Curve 6 Cleaning This probe does not require any particular cleaning If necessary clean the case with a soft cloth WARNING Dry the probe thoroughly before attempting to make voltage measurements CAUTION Avoid immersing or using abrasive cleaners or solvents containing Benzene or similar solvents on the probe as these can cause deterioration of the probe body and cables ...

Страница 11: ...t be covered by this warranty Testec Elektronik GmbH reserves the right to discontinue models change specifications price or design of this device at any time without notice and without incurring any obligation whatsoever The purchaser agrees to assume all liabilities for any damages and or bodily injury which may result from the use or misuse of this device by the purchaser his employees or agent...

Страница 12: ...robe User s Manual 2019 TESTEC Elektronik GmbH All rights reserved Unauthorized duplication of TESTEC documentation materials is strictly prohibited Customers are permitted to duplicate and distribute TESTEC documentations for internal educational purposes ...

Отзывы: