background image

© TPI Europe 2021 

1                            TPI 9085 User Guide V1.0 

 

Vib Meter 9085 

 

 

User Guide: Version 1.0 

 

 

Vibration Monitoring & Analysis 

 

 

 

Test Products International  

9615 SW Allen Blvd   Suite 104 

Beaverton, OR 97005 USA 

Tel: 

(800) 368-5719

              Fax: 

(503) 520-1225

 

 

Web site:

 www.testproductsintl.com

  

 

Содержание Vib Meter 9085

Страница 1: ...er Guide V1 0 Vib Meter 9085 User Guide Version 1 0 Vibration Monitoring Analysis Test Products International 9615 SW Allen Blvd Suite 104 Beaverton OR 97005 USA Tel 800 368 5719 Fax 503 520 1225 Web...

Страница 2: ...ASSET MANAGEMENT 13 4 C TREND II TRENDING SOFTWARE 14 5 SPECIFICATIONS 15 6 BASIC OPERATION 16 Disclaimer This document has been carefully prepared and checked No responsibility can be assumed for in...

Страница 3: ...red analysed and trended with the included VibTrend PC analysis software 1 1 Special Requirement for Temperature Measurements To measure temperature with the 9085 the accelerometer with built in tempe...

Страница 4: ...85 from the protective boot by prying the boot off from the bottom Set the 9085 on the charging pad so the symbol comes in contact with the pad The display of the 9085 will turn on to indicate it is c...

Страница 5: ...cle button to turn the unit ON Place the sensor on a rigid part of the machine as close as possible to the desired measurement point e g bearing block using the magnet mount Pressing the circle button...

Страница 6: ...ean ISO value mm s The ISO value in mm s or inch s is the large number displayed at the top of the screen which is the RMS average of the vibration velocity in the frequency band 10Hz 600 RPM to 1kHz...

Страница 7: ...This reading is shown in units of g Earth s gravitational constant where 1g 9 81 m s2 Displacement Pressing either the left or right arrow button when the reading screen is displayed will cause the me...

Страница 8: ...ignment This is based on the fact that shaft misalignment can result in a double peak in the waveform due to there being two different centres of gravity one from each shaft In other words the acceler...

Страница 9: ...s It is possible to use live update with the basic readings screen the VA bands screen or 100 line frequency spectrum Pressing the circle button at any time during live update will capture a full 800...

Страница 10: ...the ISO alarm levels to be set accordingly as does specifying the type of mounting rigid or flexible As a basic rule of thumb unless a machine is bolted down to a concrete floor its mounting should b...

Страница 11: ...2 3 3 3 Sensor mV g Accelerometer sensitivity in mV g can be manually set using the up and down arrow buttons to allow use of any desired sensitivity sensor within the range 1mV g to 1000mV g This ena...

Страница 12: ...countdown timer goes to zero to save the temperature reading This can be useful if you would like to control when the reading is saved In auto mode the temperature reading will be saved automatically...

Страница 13: ...ected using the circle button The various options for each measurement point MP are then displayed 1 Take Reading takes a new reading and saves it to this MP 2 Save Reading saves the previously taken...

Страница 14: ...stalled go to the activation screen and email the Hardware Key that is displayed to tech testproductsintl com C Trend II is very intuitive and very easy to drive and its full functionality is describe...

Страница 15: ...s or inch s Bearing noise in BDU bearing damage units Displacement mm microns inch Temperature F C Displayed Frequency Units Hertz Hz RPM or CPM Input range User selectable with accelerometer sensiti...

Страница 16: ...alarm colour coded in Green Amber and Red Additional screens show temperature displacement mm or microns frequency spectrum with cursor and diagnostics for unbalance misalignment and looseness Power O...

Отзывы: