TI5679 MPU-24
13
3
Operating Procedures
24
3.9 – Normal Function Test Procedures
This section involves “normal function” test proce dures, and includes steps necessary to ensure that the
TI5679 MPU-24 is operating within specified para meters prior to use. A digital multimeter (an example is
shown in Figure 3.9.1) capable of measuring dc and ac voltage and resistance will be required to perform
some of the tests. These functional test procedures should become routine.
Figure 3.9.1 – Digital Multimeter
Check Unit for Evidence of Damage
Check for dents, punctures, case distortion or misalignment, and cracked or loose connec tors. If no damage
is evident, proceed to the next step. If damage is evident, contact Tesla™ Industries, Inc.
Figure 3.9.2 – AC Input Connector wiring diagram
AC Hot
Pin “K”
AC Neutral
Pin “M”
AC Ground
Pins “J,L”