PARTIAL HOME BACKUP

Heavy loads cannot be supported by Powerwall

Heavy loads in existing  

non-backup subpanel

Heavy loads on non-backup  

internal panelboard

1

2

See 

System Wiring Diagrams

 in the 

Installation Manual

 

for detailed diagrams of common configurations

Backup Loads

Non-Backup Loads

High Demand Loads

LEGEND

REQUIRED TOOLS

MOUNT POWERWALL

SUGGESTED TOOLS

1/4”

5/16”

7/16”

3/16”

Material

Minimum Embedment

Wood Studs

2 1/2”

Plywood

1/4” beyond back of plywood 

(min 1/2” plywood)

Metal Studs

3 threads beyond 

stud / backing

Concrete / Masonry

1 1/2”

Channel Strut

2 1/2” into wood studs

3 threads beyond metal studs

A

B

A

B

See 

Powerwall Mounting Details

 in the 

Installation Manual

 for additional details

3

Max 9 mm

Содержание Powerwall

Страница 1: ...s and Generation Main Neutral Terminals Load Generation Neutral Terminals Neutral Ground Bonding Strap Non Backup Loads Optional Internal Panelboard SYSTEM WIRING CONFIGURATIONS Backup Gateway With In...

Страница 2: ...ations Backup Loads Non Backup Loads High Demand Loads LEGEND REQUIRED TOOLS MOUNT POWERWALL SUGGESTED TOOLS 1 4 5 16 7 16 3 16 Material Minimum Embedment Wood Studs 2 1 2 Plywood 1 4 beyond back of p...

Страница 3: ...SIDE CABLE ENTRY REAR CABLE ENTRY CLICK 4 5 MOUNT THE BACKUP GATEWAY 6 7 BOTTOM REAR OR SIDE CABLE ENTRY OPTIONAL TOP CABLE ENTRY VIA CONDUIT HUB KIT x4 included Sealing washers must be installed...

Страница 4: ...BONDING STRAP YES GATEWAY IS INSTALLED AS SERVICE EQUIPMENT INSTALL MAIN BREAKER See Wiring Reference in the Installation Reference Manual for breaker types MAKE BACKUP GATEWAY AC POWER CONNECTIONS 9...

Страница 5: ...P PANEL CONDUCTORS 1 275 in lbs 120 in lbs 5 16 3 16 6 AWG 250 kcmil 6 AWG 250 kcmil 6 AWG 250 kcmil 14 AWG 2 0 1 275 in lbs 120 in lbs 5 16 3 16 6 AWG 250 kcmil 14 AWG 2 0 14 AWG 2 AWG 14 AWG 2 AWG O...

Страница 6: ...OR 13 12 MAKE POWERWALL AC POWER CONNECTIONS INSTALL BREAKER HOLD DOWN BACKUP INTERNAL PANELBOARD NON BACKUP INTERNAL PANELBOARD 11 7 16 10 8 AWG 10 8 AWG 10 8 AWG...

Страница 7: ...Drain CN Ground CN 12 V GND MULTI POWERWALL COMMUNICATION WIRING CONNECT COMMUNICATION WIRING 14 3 8 in 18 16 AWG 24 16 AWG 18 16 AWG 24 16 AWG...

Страница 8: ...G OVERVIEW Correct Metering Installation LABEL CT ORIENTATION CT Label Source of Power Incorrect Metering Installation Power Flow Power Flow INSTALL OPTIONAL REMOTE DISABLE SWITCH 15 See Install Optio...

Страница 9: ...tem wiring diagrams with meter placement and instructions for installing a remote Neurio meter 18 CLOSE WIRING COMPARTMENTS AND POWER ON 19 AND OR 17 HOMEOWNER NETWORK CONNECT BACKUP GATEWAY TO THE IN...

Страница 10: ...e Work in one browser tab only For security message Your connection is not private select Advanced and Proceed For Error Bad Credentials select FORGOT PASSWORD to reset password For Error Login Error...

Отзывы: