TI2500 GPU-24
9
2
Product Overview
2.8 – AC Input Circuit Breakers
The AC input circuit breakers are located above the AC Input Connector. When the circuit breaker has been
tripped, either of the red buttons will pop out. In the event that the breaker trips:
Disconnect the ac and dc connectors. (Unplug ac line cord on military unit.)
1.
Wait for a minimum of 60 seconds.
2.
Reset breaker(s) by pressing red button(s).
3.
Reconnect ac and dc connections to the unit. (Plug in ac line cord on military unit.)
4.
The unit should power up automatically. If the breaker continues to trip, return the unit to Tesla™ Industries
for repair.
Figure 2.8.1 - AC Input Circuit Breakers
(outlined in blue)
2.9 – AC Input Connector
The GPU is outfitted with a 3-prong receptacle (see figure 2.9.1 below). The mating cable is keyed and will
fasten securely into the AC Input Connector.
Figure 2.9.1 - AC Input Connector
(outlined in blue)
Figure 2.8.2 - Pressing Circuit Breaker
Содержание 6130-01-452-2777