8. Cooling and fan operation 

20    

D SERIES Tesira Quick Start Guide  rev 2.0.0

8. Cooling and fan operation 

D Series devices use a forced-air cooling system with airflow from front to rear, allowing high continuous power 
levels without thermal problems. To facilitate maximum air flow, ensure that no objects such as rack doors or 
lids are placed at the front or rear of the rack. Never attempt to reverse the airflow. Make sure an adequate air 
supply is provided in front of the D Series device, and that the rear of the device has sufficient space to allow 
air to escape. It is recommended to keep the ambient temperature around the device as cool as possible. An 
increased temperature can have a significant negative impact on the expected lifetime on the components 
inside the D Series device. 

NOTE: Fit solid blanks (not ventilation blanks) to unused rack spaces to ensure effective air circulation. Leaving 
gaps in between items of equipment degrades the effectiveness of forced-air cooling. 

If installing one or more D Series devices in a rack with other fan-cooled equipment, confirm that all other 
equipment also uses front-to-rear airflow for cooling. If this precaution is not observed, there is a risk of 
overheating, as units with the reverse airflow will be drawing in air which has already been heated by the 
D Series devices.

The D Series device is equipped with a sophisticated temperature sensing system which protects it from any 
overheating which may occur as a result of inadequate ventilation.

9. Operating voltage 

D Series has a universal power supply and its mains nominal and operating voltages are specified in the Technical 
Specifications (pages 22-23). D Series can be ordered with a variety of mains plugs. If the mains plug (AC plug) 
fitted to the mains cable (AC cord) is not appropriate for your country it can be removed and a locally-sourced one 
fitted instead. If you are not 100% confident of your competence to replace the mains plug (AC plug), the task 
should be carried out by qualified personnel.

NOTE: In-rush current is controlled and limited during the soft-start sequence. This enables multiple D Series 
Devices on the same AC mains circuit to be turned on simultaneously. 

9.1. Low voltage country considerations 

Although the D Series has a wide range of operating mains voltage, some considerations can be applicable for 
low voltage regions. D Series performs well throughout the specified nominal voltage range but has slightly better 
efficiency at higher voltages. For regions with nominal voltage below 140 V, one could consider connecting the 
amplifier in a three-phase delta or two phase split-phase configuration.

NOTE: Following connections applicable only for resulting voltage inside the amplifiers nominal voltage range.

Содержание D 120:4T

Страница 1: ...DSERIES High Powerinstallationplatform Rev 2 0 0 Quick Start Guide Tesira Variants D 200 4T Ta D 120 4T Ta D 80 4T Ta Incorporating technologies from Item no QSG DSERIES TESIRA...

Страница 2: ...e risk of fire or electric shock do not expose this apparatus to rain or moisture 17 Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids such as vases...

Страница 3: ...for the European Electro Magnetic Compatibility EMC directive This equipment has also been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules...

Страница 4: ...4 DSERIESTesiraQuickStartGuide rev2 0 0...

Страница 5: ...5 DSERIESTesiraQuickStartGuide rev2 0 0...

Страница 6: ...e choc lectrique n enlevez pas les couvercles Il n y a pas des parties serviceable l int rieur tous reparations doit etre faire par personnel quali seulment EMC European Electro Magnetic Com patibilit...

Страница 7: ...lac sur l appareil Fran ais Cet appareil doit tre raccord une prise secteur avec terre de protection Fran ais Lorsque la prise du r seau d alimentation est utilis s comme dispositif de d connexion ce...

Страница 8: ...tation lectrique pour d brancher l appareil du secteur 16 AVERTISSEMENT pour r duire le risque d incendie et de choc lectrique n exposez pas cet appareil la pluie ni l humidit 17 N exposez pas cet app...

Страница 9: ...autres appareils tels que les radior cepteurs L absence d interf rences n est toutefois pas garantie pour une installation donn e Si cet quipement provoque des interf rences nuisibles la r ception de...

Страница 10: ...nnen 16 WARNUNG Um die Gefahr eines Feuers oder eines elektrischen Schlages zu verringern darf dieses Ger t nicht Regen oder starker Feuchtigkeit ausgesetzt werden 17 Setzen Sie dieses Ger t nicht tro...

Страница 11: ...n der Federal Communications Commission FCC f r digitale Ger te der Klasse B nach Abschnitt 15 Diese Einschr nkungen sollen angemessenen Schutz vor sch dlichen St rungen durch elektrische Ger te gew h...

Страница 12: ...ste aparato quede expuesto a la lluvia o la humedad 17 No permita que este aparato quede expuesto a salpicaduras de ning n tipo y no coloque objetos que contengan l quidos como jarrones encima de este...

Страница 13: ...europea de compatibilidad electromagn tica EMC Tambi n se ha verificado que este aparato cumple con los l mites establecidos para dispositivos digitales de clase A de acuerdo a lo expuesto en el apart...

Страница 14: ...Mains connection grounding 3 3 4 2 Speaker output hazard on amplifiers 3 3 4 3 Radio interference 3 3 4 4 Speaker damage 3 3 4 5 Maintenance 3 5 Introduction 16 5 1 Welcome 16 5 2 D Series Two versio...

Страница 15: ...12 Signal flow and processing 25 13 Quick Start Tutorial 26 13 1 Software installation and firmware update 26 13 1 1 Tesira Software 26 13 1 2 Firmware update 26 13 2 Network setup 27 13 3 System set...

Страница 16: ...to ensure familiarity with the various configuration and control options Thank you again for placing your confidence in Lab gruppen products 5 2 DSeries Twoversionsavailable D Series is an advanced h...

Страница 17: ...nment software incorporates ESP Equipment Specification Predictor to assist in design equipment specification and commissioning Features controlled by on board DSP Input Gain Sensitivity Input gain se...

Страница 18: ...dust filter assembly NOTE Depending on the model the connector kit might include more connectors than applicable for the product you have Select those connectors required for your unit and applicatio...

Страница 19: ...s to the amplifier with magnets Hold the front grille with your fingers in each of the side cutouts and slide it gently into place straight from the front NOTE Always ensure the dust filters behind th...

Страница 20: ...ich has already been heated by the D Series devices The D Series device is equipped with a sophisticated temperature sensing system which protects it from any overheating which may occur as a result o...

Страница 21: ...3 phase delta 208V 208V 2 0 8 V 2 0 8 V L1 L2 L3 Connecting the amplifier in a split phase configuration In two phase split phase configuration there are two phases separated by 180 degrees Connectin...

Страница 22: ...h of the button toggles the amplifier between ON and SLEEP state Channel Status and Control 7 LOAD LED for load related status indication 8 AMP LED for amplifier related status indication 9 SIGNAL LED...

Страница 23: ...evice configured and ready to participate in a system Device is ready and waiting to receive a configuration Device is not ready to receive a configuration Power Mains power not available Device is ON...

Страница 24: ...Ethernet AVB digital audio network 3 Serial control port on a DB 9 for integration control 4 Terminal block connector for Logis I O 4 pins of GPIO and a ground 5 Analog inputs on Tesira Analog versio...

Страница 25: ...k in the Tesira output section 4 Level block in the Tesira output section 5 Invert block in the Tesira output section 6 Amplifier gain Digitally implemented for exact control and management of gain st...

Страница 26: ...ervers Update Tesira server firmware 1 Download Tesira Firmware from biamp com www biamp com products tesira downloads aspx Locate the Software and Firmware section and download the latest version of...

Страница 27: ...t to obtain IP addresses automatically The Tesira device will receive an IP address automatically from a DHCP server if present or assign itself an IP address in the Link local range 169 254 1 0 throu...

Страница 28: ...nd a speaker Create Tesira system configuration 1 Open Tesira software 2 Select Labgruppen amplifier from the Object bar I O Blocks 3 Click somewhere in the layout window to place an amplifier in the...

Страница 29: ...nd click the reset device button to the left 2 Enter the Equipment table via System equipment table 3 For both the server and the amplifier click the cell in the serial number or host name column and...

Страница 30: ...s and highlights the current amplifier NOTE If a firewall is installed on your computer you must give the CAF application permissions to talk to the amplifiers Within CAF you can configure basic ampli...

Страница 31: ...ITCH Mains glitch missing cycles was detected on the mains inlet Check mains distribution connection Warning Temperature warning power supply TEMP WARN PSU Power supply temperature approaching critica...

Страница 32: ...below thresholds Check load or calibration Warning Speaker damaged SPKR DAMAGED One LoadPilot tone is above or below threshold Check load or calibration Fault No load NO LOAD At least one LoadPilot t...

Страница 33: ...ain Digital configurable amplifier gain 22 44 dB Pilot tone generation and analysis LoadPilot Load impedance analysis Yes Temperature control Regulated fans and show must go on limitation ATL PTL Audi...

Страница 34: ...tional device software select functionality Mains Power Nominal voltage 100 240 V AC 50 60 Hz Operating voltage 70 265 V AC 45 66 Hz Mains wall plug Selectable on order CEE 7 7 Schuko 230 V 16 A NEMA...

Страница 35: ...d by the warranty Units on which the serial number has been removed or defaced will not be eligible for warranty service Lab gruppen shall not be responsible for any incidental or consequential damage...

Страница 36: ...zation number Please note for product return 1 Use the original packing 2 Include a copy of the sales receipt your name return address phone and fax number email address and description of the defect...

Страница 37: ...37 DSERIESTesiraQuickStartGuide rev2 0 0 Notes Notes...

Страница 38: ...38 DSERIESTesiraQuickStartGuide rev2 0 0 Notes Notes...

Страница 39: ...39 DSERIESTesiraQuickStartGuide rev2 0 0 Notes Notes...

Страница 40: ...CDM BEL UVL CAF ESP ISVPL Iso Float Raised Cosine MESA EQ LimiterMax and LoadLibrary are trademarks of Lab gruppen AB Tesira is a trademark of Biamp Systems All other trademarks remain the property of...

Отзывы: