7
Dimensions L x W x H
360 x 180 x 150 mm (14.2 x 7.1 x 5.9”)
Weight
12 kg (26.5 lbs) approx.
Cable length to NSG
2 m (79”)
Input cable
NSG 3000 standard cable to be used
Part designation
Function
EUT power in switch
Switches on/off the EUT power supply
16 AT fuse
Protects the EUT power supply line
EUT power in plug
This is where the EUT power needs to be
applied – use NSG 3000 supplied cable
and conect it to power source (mains)
EUT power out cable
Connect this cable to the EUT supply
input port of NSG 3000
Red selector
To switch variable voltage to 0 or 40% or
70 or 80% of Uin
1.2.1 Parts description
1.3 Installation
The equipment should be switched off during installa-
tion and interconnection.
Connect INA 6501 - EUT power out to NSG - EUT power input.
Connect INA 6501 - EUT power in to mains using EUT power in cable
(delivered with NSG).
Содержание INA 6501
Страница 1: ...1 MANUAL AUTOMATED STEP TRANSFORMER INA 6501 INA 6502 USER MANUAL 601 262C...
Страница 4: ......