CBA 100M-110 User Manual

The following specification applies over the operational temperature and fre

-

quency range unless otherwise stated, and does not include the characteristics 
of connecting cables.

5 speCifiCAtion

Frequency range (instantaneous)     

0.01–100 MHz

Rated output power  

 

  

100 W minimum

Output power at 1 dB gain compression  

90 W minimum  

Gain  

 

 

  

51 dB

Third order intercept point  

  

61 dBm

Gain variation with frequency  

  

±2 dB

Harmonics at 90 W output power    

Better than -20 dBc

Output impedance  

 

  

50 Ohms

Stability 

 

 

  

Unconditional

Output VSWR tolerance    

  

Infinity:1

Input VSWR   

 

  

2:1

RF connector style  

 

  

Type N female

Safety interlock  

 

  

BNC female, s/c to mute

USB interface  

 

  

Optional

EMC and safety

Conducted and radiated emissions  

EN 61326 class A

Conducted and radiated immunity   

EN 61326: 1997 table 1

Mains harmonic currents    

  

EN 61000-3-2

Voltage fluctuations and flicker 

  

EN 61000-3-3

Safety  

 

 

  

EN 61010-1

Содержание CBA 100M-110

Страница 1: ...1 CBA 100M 110 10 KHZ to 100 MHZ 100 watt amplifier user Manual 601 292A...

Страница 2: ...CBA 100M 110 User Manual CBA 100M 110 10 KHZ to 100 MHZ 100 watt amplifier USER Manual...

Страница 3: ...2 Introduction 7 2 1 CBA 100M 110 Introduction 7 3 Unpacking and installation 9 3 1 Unpacking 9 3 2 Installation 9 4 Operation 10 4 1 Front panel 10 4 2 Rear panel 11 5 Specifications 12 6 Warranty 14...

Страница 4: ......

Страница 5: ...de or implode during normal operating conditions In normal operating conditions this apparatus does not liberate injurious or poisonous gases Sound levels of this apparatus after installation in a rac...

Страница 6: ...in a socket outlet provided with a protective earth contact The protective action must not be negated by the use of an extension cord without a protective conductor The opening of covers or removal o...

Страница 7: ...voltage range operation The unit is air cooled with integral fans and is protected against faulty cooling by excess temperature sensing A front panel indicator is provided to indicate over temperature...

Страница 8: ...inside a screened enclosure and fit an interlock to the entry door to prevent access while the amplifier is operating Amplifier self oscillation caused by feedback from un terminated con nectors This...

Страница 9: ...for the carrier s inspection Check that the equipment is complete as in the packing list above 3 2 Installation 3 Unpacking and installation 10 kHz to 100 MHz amplifier CBA 100M 110 Power cable UK Po...

Страница 10: ...the amplifier has cooled down RF input depending on model The RF input will accept a signal from an rf generator This input must be within the operating frequency range of the amplifier An amplitude...

Страница 11: ...ains input must be rated at 10 A to ensure proper operation at the minimum line voltage of 85 Vac The fuse holder is integral with this mains connector Use 6 3 A anti surge T Input output connectors d...

Страница 12: ...m Gain 51 dB Third order intercept point 61 dBm Gain variation with frequency 2 dB Harmonics at 90 W output power Better than 20 dBc Output impedance 50 Ohms Stability Unconditional Output VSWR tolera...

Страница 13: ...ring 341 715 Bench model with front panel mounted input output connectors 341 815 Rack mountable with front panel mounted input output connectors 341 925 Rack mountable with rear panel mounted input o...

Страница 14: ...the defective item or refund the purchase price paid for the defective product Transportation of the defective product or part to the factory or service centre is to be pre paid by the customer All pr...

Страница 15: ...15 NOTES...

Страница 16: ...6 10 8460 8080 F 86 10 8460 8078 chinasales teseq com Germany Teseq GmbH T 49 30 5659 8835 F 49 30 5659 8834 desales teseq com Singapore Teseq Pte Ltd T 65 6846 2488 F 65 6841 4282 singaporesales tese...

Отзывы: