18 PERPENDICULARITY & STRAIGHTNESS MEASUREMENT
18.1 Generality
Apart from the standard measurement
ST1
,
ST2
, angle measurement
and parallelism
measurement
modes, the MICRO-HITE and MICRO-HITE+M have also been especially
designed to allow the user to detect form and orientation errors. In other words, they can also
be used to determine perpendicularity and straightness deviations.
This mode is accessible from the main menu by activating the key
at any moment.
There are several types of accessories that, together with the MICRO-HITE or MICRO-HITE+M,
allow this determination. Below several possible configurations (non-exhaustive list):
+
TESA IG13
All TESA USB 1D probes
Standard TESA 1D probe
+
Display Twin-T10
Except for a joint use with the IG13, any other configuration cannot claim to reach other
specifications than the ones announced as a mechanical frontal perpendicularity error since the
values of the accessories are not compensated. For further information, please contact your
local reseller.