Operation and Maintenance Guide  ADPB 15 Plastic Pump Series

Warranty Certificate

Every product manufactured by Teryair

 is built to meet the highest standards of quality.

Teryair warrants that the Products, accessories and parts manufactured or supplied by the company be 

free from defects in material and workmanship for a period of six months from date of Teryair authorized 

dealer invoice to customer, or one year from date of Teryair invoice to dealer, whichever is earlier. Failure 

due to normal wear, misapplication, or abuse is, of course, excluded from this warranty.

Since the use of Teryair products and parts is beyond our control, Teryair cannot guarantee the suitability 

of any product or part for a particular application and Teryair shall not be liable for any consequential dam-

age or expense arising from the use or misuse of its products on any application. Teryair does not war-

ranty bought out products or components such as electric motors and hardware but will assist in directing 

warranty queries to the dealer/manufacturer responsible. Teryair responsibility is limited solely to replace-

ment or repair of defective Teryair products or components.

Dealer/End User shall have no right or remedy and Teryair shall have no liability or obligation under the warranty, if: (i) a Product is altered, 

changed, modified or tampered with in any way, (ii) a Product is damaged after deposit with the transporter for shipment; (iii) a Product is not 

properly preserved, packaged, stored, processed or handled after receipt; (iv) a Product is not used and maintained in accordance with Teryair’s 

recommended operating and maintenance manuals, instructions and procedures, if any; (v) a Product is not properly incorporated or installed in, 

or not properly combined with, an Other Product; (vi) the issue with a Product is directly or indirectly attributable to, or directly or indirectly results 

from or arises out of, a failure, substandard performance or other issue with another product, material, component or part not supplied by Teryair; 

(vii) the issue with a Product is directly or indirectly attributable to, or directly or indirectly results from or arises out of, compliance with any de-

sign, specification or other specific requirement of Dealer/End User; (viii) a Product is used in a manner, with a substance or for a purpose other 

than the normal manner, substance and purpose for which it is intended or is otherwise subjected to abnormal use or service; (ix) a Product is 

subjected to a power surge, brown out or other similar occurrence; (x) the issue with a Product is directly or indirectly attributable to, or directly or 

indirectly results from or arises out of, normal wear and tear of such Product (including, without limitation, things such as worn seals, diaphragms, 

balls, O rings, gaskets, chisels, cutters, hoses and other such wearing components; (xi) the issue with a Product is directly or indirectly.

Model Number 

: ADPB 15 PPT

Serial Numbar  

Dated 

  : 

Ajay Bhagat, Q.A. Manager
(Company Seal)

Содержание ADPB15PPT

Страница 1: ...ad this manual carefully before installing operating or servicing this equipment It s the responsi bility of the employer to ensure this manual is read by the operator Please preserve this manual This...

Страница 2: ...Instructions 5 Suggested Lubricants 5 Suggested site selection and installation recommendations 7 Troubleshooting 8 Maintenance 8 Bill of Materials for ADPB15PPT Pumps 9 Exploded View for ADPB15PPT Pu...

Страница 3: ...being pumped may spray out from the exhaust of the pump This may cause severe injury depending on the fluid being pumped If the fluid is hazardous pipe away the exhaust to a safe remote location using...

Страница 4: ...standing Please ensure that all operators have read this manual and have the required understanding of safe working practices and are equipped with safety equipment when working on around the pump Cau...

Страница 5: ...Deg C Below 5 Deg C Shell Toona R 72 Toona R 41 Toona R 27 Mobil Almo 529 Almo 527 Almo 525 Esso Arox EP 65 Arox EP 45 Caltex Rando Oil 150 Rando Oil 100 Rando Oil 46 Texaco Regal Oil F Regal Oil PE...

Страница 6: ...tor bowl Too thick oil may slow down the valve shifting mecha nism and affect pump performance See suggested lubri cants on page no 5 Piping A minimum number of bends and fittings to be used A flexibl...

Страница 7: ...seals these components need to be replaced as a set if they are worn Insufficient or wrong lubricant in the air supply Ensure that the lubricant is as per the recommended chart a thicker lubricant oft...

Страница 8: ...1 16 176 21 02 Secondary Shaft 1 17 176 40 01 Gasket for Blocking Pad 1 1 1 18 176 40 02 Back up Diaphragm 2 2 19 176 40 03 Seal for secondary shaft 6 6 20 176 40 04 Seal for primary shaft 2 2 21 176...

Страница 9: ...02 Page 9 Operation and Maintenance Guide ADPB 15 Plastic Pump Series Exploded View for ADPB15PPT Pump 1 27 29 32 33 13 14 23 12 4 3 30 31 6 9 10 11 15 16 18 19 20 26 34 32 1 35 37 38 17 39 5 7 8 22 2...

Страница 10: ...FF MM 360 REV 02 Page 10 Operation and Maintenance Guide ADPB 15 Plastic Pump Series Dimensional Data ADPB15PPT...

Страница 11: ...sions of the following European Directives 2006 42 EC Machinery Safety and Har monized standards ISO 12100 1 2010 Safety of Machinery general Principles for Design Risk Assessment and Risk Reduction R...

Страница 12: ...amaged after deposit with the transporter for shipment iii a Product is not properly preserved packaged stored processed or handled after receipt iv a Product is not used and maintained in accordance...

Страница 13: ...FF MM 360 REV 02 Page 13 Operation and Maintenance Guide ADPB 15 Plastic Pump Series This page is intentionally Left blank...

Отзывы: