Teryair 59 12 01 Скачать руководство пользователя страница 3

FF-MM-319-REV - 02

Page 3

Operation and Maintenance Guide Electric Needle Scalers

   Introduction

Teryair Electric Needle Guns are rugged tools. Designed to be easy to use and maintain. they are 

ideal for removing layers of paint, corrosion and chemical coatings from surfaces. Rotating handle 

can be fixed at any position to make operation easier.

Safety Instructions

    

Warning

This manual must be read and the operating 

instructions carefully followed.

Warning

Safety and protective clothing, eyewear, head-

gear, ear protection, gloves, and footwear to be 

worn during operation of this Electric Needle 

Scaler. 

Warning

Operators under 18 are not allowed to oper-

ate this Electric Needle Scaler. Operators must 

be made familiar with the instructions in this 

manual before attempting to operate the Electric 

Needle Scaler. Ensure that the job site is clear of 

bystanders 

Following symbols are used through out this 

manual.

   Intended Use

•  Removal of Coatings.
•  Hold cleaning, general deck and surface 

cleaning, removal of heavy rust on tankers, 

and dry dock applications.

•  Tank descaling, Descaling of structures 

before painting.

•  Paint removal.
•  Other industrial coating removals from 

floors and other surfaces.

•  Removal of concrete residue from re-bar 

Cleaning cement from plant and vehicles. 

•  Weld cleaning.
Prohibitive use
•  Any use in an explosive atmosphere is 

prohibited.

•  Use of materials containing asbestos is 

prohibited.

•  Use by an underage, untrained, or person 

who is under the influence of drugs or 

alcohol.

•  Use with non-genuine spare parts or acces-

sories is prohibited.

Note 1: Standard equipment includes one set of 3mm Needles, replacement needles sets available.
Note 2: Optional needles in 2mm with corresponding needle supporters can be ordered separately.

Technical Data

Teryair Model No

ENS100V

ENS200V

IMPA Code

59 12 01

59 12 03

Power Supply (AC)

110V-1Ph

220V-1Ph

Overall length LxWxH mm

480 X 240 X 100

Rated Power Consumption (W)

900

900

Rated Current (A)

6.0

3.0

Duty Cycle (Min)

10 - 12

10 - 12

Needle Stroke (mm)

20

20

Stroke Speed (Min)

2900

2900

Needles (Qty)

2mm X 53 pcs. Or 3mm X 23 pcs.

Power Cord Length (Mtr)

2

2

Weight (Kg)

7

7

Содержание 59 12 01

Страница 1: ...220V 1ph 59 12 03 Read this manual carefully before installing operating or servicing this equipment It s the responsi bility of the employer to ensure this manual is read by the operator Please prese...

Страница 2: ...oduction 3 Technical Data 3 Safety Instructions 4 Operating Instructions 6 Diassembly and Re assembly for ENS 100V ENS 200V 8 Bill of Materials for ENS 100V ENS 200V 9 Exploded View for ENS 100V ENS 2...

Страница 3: ...ing general deck and surface cleaning removal of heavy rust on tankers and dry dock applications Tank descaling Descaling of structures before painting Paint removal Other industrial coating removals...

Страница 4: ...ot designed for use in an explosive environment Warning Always use both hands during operation Do not run the scaler continuously for more than 15 minutes to avoid overheating Take must be taken to se...

Страница 5: ...the two screws as shown to remove the rear cover of female plug to see the terminals Insert the cable from the back of the cover through the holder and terminate the respective wire Make sure to tigh...

Страница 6: ...First remove the Lock 14 Now rotate the front cover 4 counter clockwise Now slide out the needle supporter 13 along with needles 12 and spring 11 Push the worn out needles 12 from the front side to r...

Страница 7: ...Maintenance Guide Electric Needle Scalers Carbon Brush Replacement Remove the screws 26 from the bottom to disassemble the cover 25 Now remove the cap 22 and pull the carbon brush 21 Replace with new...

Страница 8: ...0 04 O Ring 1 1 11 655 51 01 SPRING 1 1 12 022 90 04OL NEEDLE 3mm x 180mm 23 23 13 022 40 45 NEEDLE SUPPORTER 3mm 1 1 14 022 90 13 SAFETY BAND 1 1 15 655 21 06 SPACER 1 1 16 655 40 05 O Ring 1 1 17 65...

Страница 9: ...FF MM 319 REV 02 Page 9 Operation and Maintenance Guide Electric Needle Scalers Exploded View for ENS 100V ENS 200V 27B 27A 26 25 7 19 22 21 20 10 16 3 15 2 14 23 12 11 9 13 24 5 6 17 4 18 8 1...

Страница 10: ...in accordance with our standard test proce dures and meets the specifications for material and performance values as published in our literature We further certify that the product has been given our...

Страница 11: ...g European Directives 2006 42 EC Machinery Safety and Har monized standards ISO 12100 1 2010 Safety of Machinery general Principles for Design Risk Assessment and Risk Reduction Registered Office 416...

Страница 12: ...d after deposit with the transporter for shipment iii a Product is not properly preserved packaged stored processed or handled after receipt iv a Product is not used and maintained in accordance with...

Страница 13: ...FF MM 319 REV 02 Page 13 Operation and Maintenance Guide Electric Needle Scalers This page is intentionally Left blank...

Отзывы: