Figure 10. The "RF input" table of the ttx410C module DVB-T/T2 standard

The „RF input" table for ttx410C module consists of following parameters:

"Modulation standard" - used to select from the "DVB-T/T2" and "DVB-C" modulation standards.  

"Preamplifier power" - used to switch on/off the power for the RF preamplifier.

"Input bandwidth" - the bandwidth of DVB-T/T2 transponder. Can be selected from values 8 MHz and 7 MHz.

"Input frequency" – the frequency of the terrestrial or cable transponder in kilohertz.  

When the tuner is locked to the DVB-T2 transponder with multi PLP modulation, the additional parameter "PLP number" 

is displayed in the "RF input" table. When the "Modulation standard" is set to DVB-C, the „Preamplifier power" parameter 

is hidden and power for the RF preamplifier is switched off; instead of the "Input bandwidth" parameter the "Symbol rate" 

parameter is displayed. Enter the value in kilo symbols per second.

 

Figure 11. The "RF input" table of the ttx410C module DVB-C standard

Once the different data values have been entered, click on Update to conclude the input settings. 

7.3.2. Input/output status table

The following information is displayed in the table “Input status”.

“Lock status” ”Locked” - the module has synchronized with the input signal; "Unlocked” - the module has not synchronized 

with the input signal.    

“Input level” - RF signal level at the module input. Level indication - approximate.

The values of the following parameters are displayed only if the module has synchronized with the input signal. 

“Modulation standard” - detected standard of the input signal. Possible values of the standard: DVB-S, DVB-S2 (tdx410C); 

DVB-T, DVB-T2, DVB-C (ttx410C).

“Frequency” - intermediate frequency (tdx410C) or RF frequency (ttx410C) at the 

module input.

“Modulation”  -  modulation  scheme  of  the  input  signal.  Possible  values  of  the 

modulation  scheme:  QPSK,  8PSK  (tdx410C);  QPSK,  QAM16,  QAM32,  QAM64, 

QAM128, QAM256 (ttx410C).

“Modulation mode” - OFDM modulation mode of the input signal (ttx410C only). 

Values: 8k or 2k.

“FEC” - forward error correction.

“Guard interval” - guard interval of OFDM signal (ttx410C only).

 “Symbol rate” - the symbol rate of the satellite transponder in kilo symbols per 

second (tdx410C only).

“SNR” - RF signal/noise ratio at the input of module.

“VBER” - bit error rate after Viterbi corrector. To get the signal without any errors at 

the output of the tuner, VBER shall not exceed 2Е-4.

“PER” - ratio of the MPEG2 transport error packets to the whole number of packets.  If 

the number of error packet is equal to zero, the opposite value to whole number of 

packets is displayed.  Packet counters are reset during RF input parameters update.

“Input bitrate” - bitrate of the input signal.

Figure 12. Input status and output status table

Содержание tdx410C

Страница 1: ...ion table NIT Network information table and SDT Service description table table regeneration 3 Safety instructions Installation of the module must be done according IEC60728 11 and national safety standards Any repairs must be made by qualified personnel Do not expose this module to moisture or splashing water and make sure no objects filled with liquids such as vases are placed near or on the uni...

Страница 2: ...ive the ACTIVITY 5 indicator blinks Perpendicular to the wall Parallel to the wall Figure 2 Mounting of the streamer 1 CA module slot PCMCIA socket 2 RF input of SAT IF signal DC output for LNB tdx410C RF input of terrestrial cable signal DC output for preamplifier ttx410C F socket 3 RF output input signal loop through F socket 4 ETHERNET control Ethernet interface RJ45 socket 5 ACTIVITY yellow in...

Страница 3: ...3 Mounting on DIN rail Figure 5 Mounting or removing to from DIN rail of plastic spacers supplied Figure 3 Mounting to DIN rail Figure 4 Mounting from DIN rail 1 2 ...

Страница 4: ...name and password The default user name and password is admin Enter the user name and password and click on Login button Note the default password admin can and must be changed as explained in the section 7 7 5 During initial configuration you need to change the default control interface TCP IP configuration as explained in the section 7 4 Control interface IP address reset to default procedure pr...

Страница 5: ...ction In the RF output status table you can see real time status of the output section The RF input table is different according to the input signal of module 7 3 1 RF input table Figure 9 The RF input table of the tdx410C module The RF input table Figure 9 for tdx410C module consists of the following parameters LNB LO frequency the LNB local oscillator lower frequency in megahertz Use 9750 MHz fo...

Страница 6: ...nal Unlocked the module has not synchronized with the input signal Input level RF signal level at the module input Level indication approximate The values of the following parameters are displayed only if the module has synchronized with the input signal Modulation standard detected standard of the input signal Possible values of the standard DVB S DVB S2 tdx410C DVB T DVB T2 DVB C ttx410C Frequen...

Страница 7: ...module can be selected and descrambling status observed In the Enable column services for output TS are selected Column CC errors shows incoming TS CC error continuity count error status Figure 13 The List of services table The service type icon meanings SD TV service HD TV service radio service Click on the Watch button to see selected channel The module will start an UDP unicast streaming via th...

Страница 8: ...s are not regenerated so even if service is descrambled some TV s might show service scrambled message because CA descriptors are left at PMT table 7 3 5 Output settings RF output On Off turns on off RF output Constellation modulation scheme of the output signal Possible values of the modulation scheme QPSK QAM16 QAM64 Code Rate FEC There are five valid coding rates 1 2 2 3 3 4 5 6 and 7 8 Guard i...

Страница 9: ...ptured automatically by adding its IP address and pressing Load button In case if the frequency was added manually already that record will be updated Otherwise a new record will be inserted 7 4 IP settings This screen Figure 19 consists of three tables Control interface IP parameters Time parameters and IP status The IP parameters tables are used to configure Ethernet connection parameters In the...

Страница 10: ...e description of the SNMP configuration table rows Read Community community name acts as a password that is shared by multiple SNMP agents and one or more SNMP managers The Read Community password is used for read only access to the modules parameters Write Community is the password used for read write access to the modules parameters Enable TRAP SNMP traps are alerts generated by agents on a mana...

Страница 11: ... and the values of these parameter are corrected Local time offset in the log is used from the time parameters table see Figure 19 You can filter required messages setting corresponding Logs filtering checkboxes 7 7 2 Export parameters All of the data established on the module can be saved onto a backup file Inversely the configuration data saved on an appropriate file can be restored on the modul...

Страница 12: ...at new password field The change of password will not take effect until you press the Modify button In the User management table you can manage users who will be able to login into the module Enter the new username and password in the appropriate fields select desired role for user and press the Add button to add new user or Update button to change settings of the user User role Admin enables the ...

Страница 13: ...eters PCR restamping up to 5 PID s services Management port standard IEE802 3 10 100 Base T Supply voltage 12 V 1 V Current consumption 400 mA 450 mA Operating temperature range 0o 50o C Dimensions Weight packed 36x198x112 mm 0 78 kg Technical specifications pr pr pr pr pr pr pr pr pr pr pr pr pr software control without external DC feeding and CAM with CAM 0 6 A absolut max with CAM and external ...

Страница 14: ...3 2 safety norm EN60065 RoHS norm EN50581 TERRA confirms that this product is in accordance with Custom Union Technical Regulations Electromagnetic compatibility of technical equipment CU TR 020 2011 On safety of low voltage equipment CU TR 004 2011 TERRA confirms that this product is in accordance with safety standard AS NZS 60065 and EMC standards of Australia Draugystes str 22 LT 51256 Kaunas L...

Отзывы: