Table 1

Powering mode

”DC to / from 
H trunk lines” 

switch position

 

(see Figure 1, 
pos.21)

”DC to / from 
V trunk lines” 

switch position

 

(see Figure 1, 
pos.23)

 Warnings and notes*

1. Multiswich powered from local 
PSU (20 V) via DC IN(H) input 

(see Figure 1, pos. 20) . 
(Recommended for use is PS202F 
PSU).
H trunk lines are DC isolated from it.

OFF

OFF

Recommended as first choice.

 

WARNING: BEFORE CONNECTION 
ALWAYS CHECK DC TO / FROM H / V 
TRUNK LINES SWITCHES

 (see Figure 1, 

pos. 21, 23).  

ITs MUST BE IN POSITION 

"OFF"!

 

Note

: All trunk lines preserve  DC 

bypassing. See “

Diagram of DC paths

".

2.Multiswich is powered from local  
PSU (20 V) via DC IN(H) input and 
with DC passing to H trunk lines.

In this mode H trunk lines can power 
in cascade other multiswiches 
(without PSU, with “DC to / from 

H lines” switch ON) and other 

equipment connected to H trunk 
lines.

ON

OFF

WARNING

: Don’t overload PSU via H 

trunk lines and don’t exceed the current 
capability of H trunk lines – check total 
system power consumption of multiswich 
and from H trunk lines (including all other 
equipment connected). See “

Technical 

characteristics

”.

Check all other system equipment 
connected to H lines if it 

can accept 20 V. 

SERIOUS DAMAGE OF IT CAN OCCUR!

3. Multiswich is powered from H 
trunk lines:

- building new SCR/dSCR system 
(18 V - 20 V)
- upgrading systems (15 V - 18 V)

ON

OFF

WARNING

: Don’t exceed the current 

capability of system power supply 
and H trunk lines. See “

Technical 

characteristics

”.

SERIOUS DAMAGE CAN OCCUR IF 
OVERLOADED!

4. Multiswich is powered from lo-
cal PSU (20 V) via DC IN(V) input

(see Figure 1, pos.23). 
(Recommended for use is PS202F 
PSU).
V trunk lines are DC isolated from it.

OFF

OFF

WARNING

BEFORE CONNECTION 

ALWAYS CHECK DC TO / FROM H / V 
TRUNK LINES SWITCHES

 (see Figure 1, 

pos. 21, 23).  

ITs MUST BE IN POSITION 

“OFF”!

 

Note

: All trunk lines preserve DC 

bypassing. See “

Diagram of DC paths

“.

5.

 and 

6.

OFF

ON

Similar to 

Powering modes

 2 and 3, but in 

relation to V trunk lines.

7. Multiswiches in large systems 
are powered from one mains point.

In this mode V and H trunk lines 
can power in cascade other 
multiswitches.
 

ON  / OFF

ON  / OFF

WARNING:  Before power “ON”, select 
the optimal combination of DC to / from 
H / V line switches 

(see Figure 1, pos. 21, 

23). 

Note

All trunk lines preserve DC bypassing. 

See

 “Diagram of DC paths“.

* Current consumption from DC IN(V) and V lines is slightly higher compared to power from DC IN(H) or H lines (see “

Diagram 

of DC paths

 

and “

Technical characteristics

).

Then switch on receiver(s). The multiswitch will begin the process of auto-detecting which type(s) of receiver connected. 

All subscriber outputs are configured to connect legacy STB (su13V/+18V/22 kHz signals), but it switches to 

dynamic mode SCR/dSCR if receives a DiSEqC command according EN50494/EN50607. 

Disconnect RF cable or STB from necessary output to reset to Legacy / 

Start mode

.

6

Содержание SRM564

Страница 1: ...ontrol for SAT IF and DTT SRM564 SRM584 signals negating the need for any gain or level adjustments in most installations Multiswitch is built into a zinc alloy die cast housing for extreme interference immunity The housing of multiswitches meets more stringent screening requirements according to EN50083 2 class A Control according to EN50494 EN50607 SCR dSCR commands as well as Legacy 13 V 18 V 2...

Страница 2: ...stem Floating voltages can be created in an un earthed system which may cause damage and can be dangerous Momentary short circuit of any cables may be enough to damage the sensitive electronics within the multiswitch or the connected system Always allow plenty of ventilation around the multiswitch and do not allow it to be covered with materials such as loft insulation We recommend at least 5 cm o...

Страница 3: ...o V H Voltage in trunk Power via DC IN Legacy dSCR DTT DiSEqC control DC to from H lines DC to from V lines Low voltage in trunk 27 22 23 19 24 25 26 Manual 13 14 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 20 11 12 15 16 17 18 21 DC IN H DC IN V 20V 2A H H V 20V 2A V DTT DTT Frequency SAT TV range DTT Trunk loss SAT TV DTT Current consumption 20 V 950 mA max 290 2350 MHz 47 862 MHz 4 dB 4 dB dSCR multiswitch ...

Страница 4: ...SCR output1 pair A UB DTT 16 dSCR output2 pair A UB DTT 17 dSCR output1 pair B UB DTT 18 dSCR output2 pair B UB DTT 19 Wideband Quattro switch 20 DC IN H 20 V power input switchable to H lines by switch pos 21 see Installation instructions 21 DC power to from H trunk lines switch see Installation instructions 22 DC IN V 20 V power input switchable to V lines by switch pos 23 see Installation instr...

Страница 5: ...Diagram of DC paths Figure 3 Diagram of DC paths 5 DC IN H DC IN V 20V 2A 20V 2A DTT H H V SAT A SAT B On Off On Off V DC to from H lines DC to from V lines DiSEqC control DC DC converter ...

Страница 6: ...N OFF WARNING Don t exceed the current capability of system power supply and H trunk lines See Technical characteristics SERIOUS DAMAGE CAN OCCUR IF OVERLOADED 4 Multiswich is powered from lo cal PSU 20 V via DC IN V input see Figure 1 pos 23 Recommended for use is PS202F PSU V trunk lines are DC isolated from it OFF OFF WARNING BEFORE CONNECTION ALWAYS CHECK DC TO FROM H V TRUNK LINES SWITCHES se...

Страница 7: ...ered from DC IN H port Attention increased current consumption Low voltage in H line Multiswitch powered from H line Voltage in H line from another system power point Attention increased current consumption Yellow blank 15 20V 0V OFF OFF 0V 0V Normal operation Multiswitch powered from DC IN V port Green blank 0V 0V ON OFF 15 20V 0V Normal operation Multiswitch powered from V line Blinking Yellow G...

Страница 8: ...DiSEqC command according EN50494 EN50607 Output User Bands UB are the same in all subscriber outputs see Table 3 3 PIN Codes see Table 3 and see chapter Configuration 4 Only one UB plan is set depended of delivery region if you need another plan see chapter Configuration or contact TERRA UAB 5 DC power to H V trunk lines switches set see Figure 1 pos 21 23 in position OFF Table 3 Marking v 0 Marki...

Страница 9: ...tal 96 UB SRM584 SRM584T total 128 UB for use with STBs supporting DiSEqC commands according to standard EN50607 dSCR 2 Default settings Dynamic mode can be changed to Static mode 3 Default setting Satellite A B can be changed to C D see Application diagrams for installation 4 wideband LNBs SAT B C D in the case Quattro LNB IF range input mode PC Windows software can be free downloaded from www te...

Страница 10: ... MHz adjustable dSCR mode dSCR mode output level 84 dBµV adjustable AGC controlled legacy mode output level 78 dBµV AGC controlled typical DTT output level 82 dBµV max 8 DTT channels AGC controlled adjustable DTT loss 18 dB Decoupling SAT IF inputs SAT IF inputs 30 dB SAT IF inputs tap outputs 30 dB SAT IF Terr TV 25 dB DC pass through SAT IF 3 2 A max 1 6 A max through one line trunk lines DTT 20...

Отзывы: