3

Power ON indication LED (see Figure 1, pos. 16) glows 

Green

 at any of the 4 powering modes.

Then switch on receiver(s). The multiswitch will begin the process of auto-detecting which type(s) of receiver connected. 

All subscriber outputs are configured to connect legacy STB (su13V / +18V/22 kHz signals), but it switches to 

dynamic mode SCR/dSCR if receives a DiSEqC command according EN50494/EN50607. 

Set the highest frequency UB for STB located nearest to the multiswitch and lowest frequency for STB farthest to the 

multiswitch. If you install less than max. possible STB’s use lowest frequencies first. 

Disconnect RF cables or STB‘s from necessary outputs to reset to legacy / 

Start mode

.

PIN code

All User Bands (UB) are protected by PIN Code to prevent the set of UB from being used/disturbed by another user (see Table 2).

Default settings

1. SAT IF inputs are configured to use Ku-band Quattro LNB (SAT A, LNB Lo=9750/10600 MHz).

2. All outputs are configured to connect 

Legacy

 STB (+13 V/+18 V/22 kHz), but it switches to 

Dynamic mode

 SCR/dSCR 

if receives a DiSEqC command according EN50494/EN50607. Output User Bands (UB) are the same in all subscriber 

outputs (see Table 2). ). All user bands are turn off (

Start mode

).

3. PIN Codes (see Table 2 and see chapter "

Configuration

").

4. Only one UB plan is set depended of delivery region, if you need another plan see chapter "

Configuration

" or contact 

TERRA UAB.

5. DC power to H trunk lines switch (see Figure 1, pos. 17) in position “

OFF

”.

Table 2

C

onfiguration

The default setting of the device can be changed using dedicated programmer and software.

These multiswitches can be configured up to 32 User Bands (UB) per pair outputs (SRM543 total 64 UB) for use with 

STB’s supporting DiSEqC commands according to standards EN50494/EN50607 (SCR/dSCR) as well as Legacy (+13 V/+18 

V/22 kHz) commands. Default settings 

Dynamic mode

 can be changed to 

Static mode

.

PC Windows software can be free downloaded from 

www.terraelectronics.com

.

Marking:                         v.0

Marking:                        v.1

Marking:                            v.2

User

Band

(UB)

PIN 

Code

Bandwidth, 

MHz

Central frequency,

MHz

Bandwidth, 

MHz

Central frequency, 

MHz

Bandwidth, 

MHz

Central frequency, 

MHz

EN50494 EN50607

EN50494 EN50607

EN50494 EN50607

UB0

46

1210

1210

UB1

1

40

1210

1210

40

1210

no

46

1420

1420

UB2

2

40

1420

1420

40

1420

no

46

1680

1680

UB3

3

40

1680

1680

40

1680

no

46

2040

2040

UB4

4

40

2040

2040

40

2040

no

46

1006

1006

UB5

5

40

1284

1284

40

no

985

46

1057

1057

UB6

6

40

1516

1516

40

no

1050

46

1108

1108

UB7

7

40

1632

1632

40

no

1115

46

1159

1159

UB8

8

40

1748

1748

40

no

1275

46

no

1261

UB9

9

40

no

970

40

no

1340

46

no

1312

UB10

10

40

no

1010

40

no

1485

46

no

1363

UB11

11

40

no

1050

40

no

1550

46

no

1471

UB12

12

40

no

1090

40

no

1615

46

no

1522

UB13

13

40

no

1130

40

no

1745

46

no

1573

UB14

14

40

no

1170

40

no

1810

46

no

1624

UB15

15

40

no

1330

40

no

1875

46

no

1731

UB16

16

40

no

1370

40

no

1940

3. Multiswich is powered from H trunk 

lines:

- building new SCR/dSCR system (18 V - 20 V)

- upgrading old legacy systems (15 V - 18 V)

ON

WARNING

: Don’t exceed the current capability of system 

power supply. 

SERIOUS DAMAGE CAN OCCUR IF OVERLOADED!

4. Multiswich is powered from Legacy/

dSCR  (subscriber) outputs

 

(see Figure 1, pos. 11-14). 

Each dSCR output circuit is individually 

powered directly from STB’s or from dSCR 

power inserter (with 22 kHz bypass). 

OFF

WARNING:  MULTISWITCH WILL DRAW CURRENT AND 

POWER FROM PAIR OUTPUT WITH HIGHER 

VOLTAGE!

 If STB’s connected to Legacy/dSCR outputs 

can’t supply sufficient power for it’s own output – dSCR 

power inserter with 20 V PSU should be used (one per out-

put of pair A or B).

WARNING

: Don’t exceed the current capability of power 

inserter and dSCR outputs (800mA max.). 

SERIOUS DAM-

AGE CAN OCCUR IF OVERLOADED!

Note

: Terr. TV amplifier can be powered from H trunk lines 

(15-20 V) to minimize current consumption from STB and 

keep Terr. TV operation when all STBs are OFF.

Содержание SRM523

Страница 1: ...sure no objects filled with liquids such as vases are placed near or on the unit Avoid placing the multiswitch next to central heating components or direct sunlight and in areas of high humidity No naked flame sources such as lighted candles should be placed on multiswitch If the multiswitch has been kept in cold conditions for a long time keep it in warm room no less than 2 hours before powering ...

Страница 2: ...ed from it OFF Recommended as first choice WARNING BEFORE CONNECTION ALWAYS CHECK DC POWER TO H TRUNK LINES SWITCH see Figure 1 pos 17 IT MUST BE IN POSITION OFF Note All trunk lines preserve DC bypassing 2 Multiswich is powered from local PSU 20 V via DC input and with DC passing to H trunk lines In this mode H trunk lines can power in cascade other multiswiches without PSU with DC to H trunk lin...

Страница 3: ...fault settings Dynamic mode can be changed to Static mode PC Windows software can be free downloaded from www terraelectronics com Marking v 0 Marking v 1 Marking v 2 User Band UB PIN Code Bandwidth MHz Central frequency MHz Bandwidth MHz Central frequency MHz Bandwidth MHz Central frequency MHz EN50494 EN50607 EN50494 EN50607 EN50494 EN50607 UB0 46 1210 1210 UB1 1 40 1210 1210 40 1210 no 46 1420 ...

Страница 4: ...ypical 78 dBµV Terr TV gain 8 dB 4 dB Terr TV output level IMD3 60 dB 104 dBµV max IMD3 60 dB 100 dBµV max Trunk output loss SAT IF 3 0 dB Terr TV 1 0 dB DC pass through SAT IF 2 A max 1 A max through one line trunk lines Terr TV 250 mA max Decoupling SAT IF inputs SAT IF inputs 30 dB SAT IF inputs tap outputs 30 dB SAT IF Terr TV 25 dB Current from DC input 20 V 270 mA max 20 V 510 mA max consump...