
STB
(set-top-box)
[
3
1
5
2
4
TV
or
Technical characteristics
Type
OD006
OD006-55
Optical input
optical wave lenght
1100-1600 nm
1550 nm
optical input level (AGC range)
-6 ...0 dBm
optical return loss
>
40 dB
noise current density
≤
6.5 pA/
√
Hz
RF output
frequency range
47-1006 MHz
impedance
75
Ω
return loss
≥
14 dB at 40 MHz-1.5 dB/octave
frequency response
± 0.75 dB
output level (AGC controlled, 4.9% OMI)
80 dBµV
output level (CTB, EN50083-3)
80 dBµV (42 ch.)
output level (CSO , EN50083-3)
80 dBµV (42 ch.)
Power consumption
DC 5 V
0.1 A
Operating temperature range
-20
o
÷
+ 50
o
C
Dimensions/Weight (packed)
72x53x19 mm/0.08 kg
Installation instructions
Read the product description and safety instruction first.
Fiber installation should be done very carefully. Bending radius of fibers must be not less 25 mm. All optical connectors and
adaptors should be cleaned before connecting them. Power on the receiver after all cables have been connected correctly.
Powering of receiver
Operating and adjusting
Optical Level Control (OLC) is active at optical input power -6 .. 0 dBm. RF level remains constant while optical input power
fluctuates in range of -6 .. 0 dBm. Out of this range receiver continues to operate though OLC is disabled.
The receiver owns optical input power indicator formed from 3 LED. Note the table below for detailed description.
Indication
OLC
Optical input power
Left LED
Middle LED
Right LED
Not glowing
Not glowing
Glowing red
OFF
> 0 dBm
Not glowing
Not glowing
Glowing green
ON
- 2 .. 0 dBm
Not glowing
Glowing green
Glowing green
ON
- 4 .. - 2 dBm
Glowing green
Glowing green
Not glowing
ON
- 6 .. - 4 dBm
Glowing green
Not glowing
Not glowing
OFF
- 20 .. - 6 dBm
Glowing red
Not glowing
Not glowing
OFF
< - 20 dBm
Requirements for external power supply unit
(PSU) for OD006, OD006-55
OD006 is powered from external 5 V DC power supply unit.
Requirements:
• Output voltage: 5 V
±
5%
• Output current: > 0.2 A
• Output connector: micro USB
• Short circuit protection
• Double insulated (marked
)
• Meet EN 55022 class B conducted emisions requirements,
measuring with grounded load
Power supply unit 5V DC with
micro USB connector
(power supply is not supplied with receiver)
Cable USB A - USB micro connector
(cable is not supplied with receiver)
1
. Optical input SC/APC
2
.
OUTPUT
-
RF signal output connector (F socket)
3
. micro USB connector
4
. Functional grounding clamp
5
. 3 LED optical input power indicator