Installation
The amplifier should be mounted vertically with RF connectors on the left.
Ground the amplifier housing. Connect the amplifier into the mains supply lastly.
14 V DC output voltage appears on Terr.IN input if 14 V DC output switch is switched on and amplifier works in insertion mode.
WARNING!
In case of
short circuit/overload of
18 V DC at RF connectors the amplifier will switch off and self recovers
when short circuit/overload will be eliminated.
*
short circuit/overload protected
** max. total for two 18 V outputs; short circuit/overload protected;
in case of short circuit/overload amplifier will be switched off till short circuit/overload removal
*** without external DC feeding, with external DC feeding 20 W
Technical characteristics
Frequency range
Terr. TV
47-790 MHz
SAT IF
950-2400 MHz
Gain (fixed slope pre-correction)
Terr. TV
30 - 34 dB
SAT IF
35 - 40 dB
Gain adjustment
SAT IF
15 dB by 1 dB step
Terr. TV
15 dB by 1 dB step
Slope adjustment
Terr. TV
15 dB by 1 dB step
SAT IF
15 dB by 1 dB step
Input and output return loss
≥
12 dB
Output level
Terr. TV
115 dBµV IMD3=60 dB, 2 equal carriers
SAT IF
120 dBµV IMD3=35 dB, 2 equal carriers
Noise figure
Terr. TV
7 dB
SAT IF
8 dB
Output test point
-30 dB
DC feeding for external, switchable
14 V 100 mA*; 18 V 800 mA**
Power consumption***
230 V~ 50/60 Hz 3.5 W
Operating temperature range
-20
0
÷
+50
0
C
Dimensions/Weight (packed)
180x135x52 mm/0.62 kg
Caution
.
Risk of electric shock.
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled
or discarded according to applicable local and national regulations.
Equipment intended for indoor usage only.
Equipment is double insulated from the mains, with functional earthing.
Functional earthing. Connect to the main potential equalization.
This product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN62368-1,
RoHS norm EN50581.
This product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of
technical equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.
This product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.
Structure diagram
RF IN
SAT IF+Terr.TV/SAT IF
RF IN
-/Terr.TV
Input
configuration
matrix
18 V
230 V~
1dB step
Test
-30 dB
RF OUT
SAT IF+Terr.TV
14 V
SAT
TERR
DC
1dB step
Terr.TV signal input
selection switch