background image

14 

This command is intended for use in critical situations where it is not possible to use other recovery method. The 

command will delete all files from the device and restore the original application from read-only memory. All 

firmware upgrades will be lost, so you will need to perform the “Firmware upgrade” (section 5.6.6) function to 

have the latest software version. Firstly the device must be powered off to call this function. Press the “Reset” 

button and turn on the power. Hold down the button for a few seconds until the LED starts flashing. When it starts 

flashing, keep it pressed further for 3 seconds until the 

red

-

green

 LED lights up. After this point, releasing the 

button will start the deletion procedure. 

7. REQUIREMENTS FOR EXTERNAL POWER SUPPLY UNIT 

• Output voltage   

 

 

 

 

+12 V ± 1V 

• Output current   

 

 

 

 

≥ 1.0 A

 

• Ripple at single and/or double mains frequency 

 

≤ 10 mV p

-p 

• Ripple and noise 

 

 

 

 

≤ 180 mV p

-p 

 

• Output connector type   

 

 

 

3.5/1.3 (+) plug 

• Short circuit protection 
• Double insulated (marked 

• Meet EN55022 class B conducted emissions requirements, measuring with grounded load 

8. Technical specifications 
HDMI video input / output resolution 

up to 1920x1080 60p 

H.264 encoder 

video encoding standard 

MPEG-4 AVC/H.264, Baseline profile 4.0 

video output resolution 

up to 1920x1080 30p 

video bit rate 

0.5 – 15 Mbps 

audio encoding standard 

AAC 

Storage 

network disk 

CIFS, SMB 

USB disk 

FAT32, NTFS, exFAT, EXT3, EXT4 

max. disk size 

4 TB 

USB 

standard 

USB 2.0 

connector type 

USB-A 

DC output 

5 V 500 mA 

IP output 

standard 

IEE802.3 10/100 Base T 

supported protocols 

DLNA, HTTP, SRT 

Control port 

IEE802.3 10/100 Base T 

Current consumption without external load 

12 ± 1 V 350 mA (MHI512) 

Current consumption with max. external 

load 

12 ± 1 V 800 mA (MHI512) 

Supply voltage limit values, power 

consumption 

100-240 V~ 50/60 Hz 11 W max. (MHI512P) 

Operating temperature 

0º C ÷ +45º C 

Dimensions/Weight (packed) 

112x35x124 mm/0.24 kg (MHI512) 

112x35x124 mm/0.34 kg (MHI512P) 

Package contents 

1.  Streamer 

…………………………….. 

1 pcs 

2.  External power supply

 

…………………………….. 

1 pcs (for MHI512P ordering number only)

 

3.  Quick start guide 

…………………………….. 

1 pcs 

4.  Safety instruction 

…………………………….. 

1 pcs 

5.  Adapter for 5.5/2.1 mm DC jack 

…………………………….. 

1 pcs (for MHI512 ordering number only) 

 

 

 

Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37 - 31 34 44, fax: +370 37 - 31 35 55 

E-mail: 

[email protected]

http://www.terraelectronics.com

 

 

Содержание MHI512

Страница 1: ...correctly The streamer shall not be exposed to dripping or splashing water Avoid placing streamer next to central heating components near highly combustible materials and in areas of high humidity If the streamer has been kept in cold conditions for a long time keep it in a warm room no less than 2 hours before use Do not place the streamer on unstable surfaces where the unit may fall and resultin...

Страница 2: ...tion light 4 Installation instructions Read the safety instructions first Connect the HDMI video output from HDMI signal source to the device HDMI IN connector using HDMI cable If required connect device HDMI OUT video output to TV HDMI video input by using HDMI cable Plug Ethernet cable and connect to the home router or personal computer Connect the device power supply to the device DC IN connect...

Страница 3: ...u can access the device by entering this URL in your WEB browser address bar http iptv local The login window should appear after a short period of time If you cannot access the login window please read troubleshooting instruction manual for possible connection problems solving NOTE mDNS is supported on Windows and MAC operating systems only If you are using other OS connect the device directly to...

Страница 4: ...EB configuration window side You can logout anytime from the WEB configuration window by pressing the logout icon Device name This name can be changed if you click on the current device title text 5 1 Home This is the default page of the device when the user logs into the control panel Figure 3 Connection diagram Figure 3 shows all possible connections and their states If there is a problem with t...

Страница 5: ...ue such as 10000 kbps Audio bitrate video stream audio bitrate Select audio bitrate preset from the dropdown list The higher the audio bitrate the better sound quality will be Click Update to apply the changes 5 3 Playlist The device supports the M3U playlist format for third party video players You can import the playlist file to your favorite video player to watch a video stream 5 3 1 Playlist p...

Страница 6: ...the type of storage between the USB and network drive Status shows the mounting status of the drive If the disk is mounted the free disk space that will be used for recordings will be displayed If the USB option is selected a list of available USB partitions will be displayed See Figure 9 Figure 9 Storage configuration If the storage type is a network drive the Network drive address field must spe...

Страница 7: ...on the News record To delete a scheduled record entry just click the icon and confirm If a video is being recorded at that time the current recording will end and be saved to a file 5 4 3 Recorded TV programs This section displays a list of recorded files After the video has been recorded it will be automatically added to this list M3U DLNA playlist files in the streamer will be updated automatica...

Страница 8: ...NS entry user assigned domain name for accessing the device WEB control interface Ensure that only one device exists in the same network with the same user specified local network DNS entry Otherwise accessing the WEB control interface by address http iptv local or other user assigned name will not work Be sure to prefix the domain name with http as some browsers may simply redirect you to a searc...

Страница 9: ...onths and is automatically issued for the device domain and will be renewed automatically Default HTTPS port 443 is used for a secure connection but can be changed by the user The domain can also point to the public IP address as well see DNS type parameter in Figure 14 Additional router forwarding is required The Force redirection flag will automatically redirect your WEB browser to a secure conn...

Страница 10: ...r password The special username admin cannot be changed All other usernames can be changed in the Username field Before setting a new password the user must enter the current password in the Current Password field Clicking Update will apply the changes 5 6 3 Users management A user with an Administrator privilege can see this menu and add remove users who can log in to the system Figure 18 shows t...

Страница 11: ...erface will check the contents of the file as soon as you select the file and prevent the import of invalid content If the content of the file is correct the screen will display the type of device and its description from which the file was exported It is also allowed to import settings from one software release to another Just keep in mind that a new version of the software may miss some of the p...

Страница 12: ... time Check the Enable check box set restart time and choose what type of restart you want to use Click the Update button to save the changes Figure 24 Device auto restart 5 6 9 Restore defaults All settings except IP parameters can be reset to factory defaults by selecting the Restore defaults submenu A confirmation message will appear on the screen asking if you really want to do this Once confi...

Страница 13: ...er useful information about the system Figure 26 Device information 6 Reset button The reset button has different functions which mainly depend on the duration of the press Device reset A short press less than 2 seconds will restart the entire system Red green LED indicates acceptance of this command This corresponds to section 5 6 7 Restart the device Full restart function IP reset Pressing the b...

Страница 14: ... with grounded load 8 Technical specifications HDMI video input output resolution up to 1920x1080 60p H 264 encoder video encoding standard MPEG 4 AVC H 264 Baseline profile 4 0 video output resolution up to 1920x1080 30p video bit rate 0 5 15 Mbps audio encoding standard AAC Storage network disk CIFS SMB USB disk FAT32 NTFS exFAT EXT3 EXT4 max disk size 4 TB USB standard USB 2 0 connector type US...

Отзывы: