27. Error Display
A Varity of errors can be recognised and displayed by the
control unit..
The red LED shines in case of an error. The illustration
shows the position of the displayed error.
The heat pump was switched off by
the High pressure switch. At more than 3 switches off this
way in 24 hours the heat pump is blocked and has to be
switched off and back on by the main switch.
The heat pump was switched off by
the Low pressure switch. At more than 3 switches off this
way in 24 hours the heat pump is blocked and has to be
switched off and back on by the main switch.
The heat pump was switched
off by the Thermo relay switch (Motor protection). At
more than 3 switches off this way in 24 hours the heat
pump is blocked and has to be switched off and back on
by the main switch.
The Groundwater
temperature is to low. After a temperature increase the
Heat pump switches back on automatically.
The Heat pump is operating for
more than 180 minutes without increasing the
temperature. As soon the temperature increases the
Heat Pump switches back on.
One of the necessary sensors
is not working. You can find out which by going to
“overview temperatures” (page 17)
The relation between operation
hours and switch impulses is bad.
The gap between flow and return temperature
of the heat pump is too big. Check mixers.
The heat pump
was switched off by the Max. temperature threshold and
will switch back on as soon the temperature reaches
49°C.
Displayed Errors:
- “1” High pressure:
- “2” Low Pressure:
- “3” Thermo relais error:
-“4” Ground water error:
- “5” Heat Pump power:
- “6” free
-“7” Sensor out of order:
- “8” check Heat Pump:
- “9” Gap:
- “10” Heat Pump Over temperature:
The red LED shines in case of an error.
The illustration shows the position of the displayed
error..
D1
D2
F1
F2
F3
F4
F5
F6
IDM-Hauptmenü 30/07/00 11:02 Uhr
Heizkreis B:
Wärmepumpe: ein
[1]
32°C,
Außen-
temp:
19
°C
20,7°C
21,2°C
Heizkreis A:
weiter
NOTE:
The errors No. 1, 2 and 3 can be acknowledged by
out and restarting of the heatpump.
The
announcement of the other errors expires, as soon
as the error cause is eliminated.
In the "
" the arisen errors can also later be
queried. In addition in the main menue turn the cursor
from the window and press the key F2. The status
report remains also after switching off of the heatpump.
status report
D1
D2
Status Report
Page 00
19.12.2003 21:23 Alarm
High pressure
15.12.2003 16:14 Alarm
Thermo relais error