Terra Universal Smart Desiccator Скачать руководство пользователя страница 2

Installation and Operating Guide  

 

Smart

 

® Desiccator 

 

Copyright 2017 Terra Universal Inc.  All rights reserved. • Revised August 2020 • Document No. 1800-16 

Terra Universal, Inc.  •  TerraUniversal.com  •  800 S. Raymond Ave.  •  Fullerton, CA  92831  •  TEL: (714) 578-6000  •  FAX: (714) 578-6020 

 

 

 

 

1.0

 

Introduction 

This manual provides installation and operating instructions that pertain to both the plastic and stainless steel Smart® 

Desiccator.  

 

2.0

 

Description 

 

The Smart® Desiccator extends shelf lives of stored materials by automatically maintaining the internal humidity level 

you select. 

 

It maintains dry storage conditions by controlling the 

flow of dry purge gas, generally nitrogen, into the 

cabinet. A space-saving LED display continuously 

monitors the %RH (relative humidity) inside the 

chamber. After you enter a humidity set point, the 

Smart® Desiccator turns the flow of nitrogen on and 

off to maintain the set point without wasting nitrogen. 

 

This smart control system cuts nitrogen costs up to 

78% when compared to flow meter gas delivery 

systems. Terra’s Automatic RB (Relief/Bleed) Valve 

relieves system overpressures that could damage 

door seals. 

 

 

 

 

 

 

 

 

 

Proprietary Notice

 

 

 

This manual pertains to proprietary devices manufactured by Terra 

Universal, Inc. Neither this document nor any portion of it may be 

reproduced in any way without prior written permission from Terra 

Universal.

 

 

Terra Universal makes no warranties applying to information contained 

in this manual or its suitability for any  implied or inferred purpose.  

Terra Universal shall not be held liable for any errors this manual 

contains or for any damages that result from its use.

 

Safety Notice

 

 

A thorough familiarity with all operating guidelines is essential to safe 

operation of the product.  Failure to observe safety precautions could 

result in poor performance, damage to the system or other property, or 

serious bodily injury or death. 

 

The following symbols are intended to call your attention to two levels 

of hazard involved in operation: 

 

Cautions are used when failure to observe instructions 

could result in significant damage to equipment. 

CAUTION 

 

 

Warnings are used when failure to observe instructions 

or precautions could result in injury or death. 

WARNING 

The information presented here is subject to change without notice. 

Содержание Smart Desiccator

Страница 1: ... Guide Document No 1800 16 Smart Desiccator Copyright 2017 Terra Universal Inc All rights reserved Revised August 2020 Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Страница 2: ...tic RB Relief Bleed Valve relieves system overpressures that could damage door seals Proprietary Notice This manual pertains to proprietary devices manufactured by Terra Universal Inc Neither this document nor any portion of it may be reproduced in any way without prior written permission from Terra Universal Terra Universal makes no warranties applying to information contained in this manual or i...

Страница 3: ...arm is displayed Identification Parameter default 0 not used with the Smart Desiccator Purge Off Delay default 5 seconds allows the user to change the delay between the time when the system regains the humidity set point and the high flow purge is de activated This delay ensures that ample purge is provided to remove moisture and contaminants from the chamber The longer the delay the more nitrogen...

Страница 4: ...dity Offset 1 To change parameter settings you must first enter the Set up Mode To do so disconnect the 12VDC plug from the side of the unit 2 While pressing and holding both red buttons labeled A and B reconnect the 12VDC plug to the power 3 Release the A button only The LED will show RH to indicate the Relative Humidity Offset Parameter 4 Release the B button The display should read the factory ...

Страница 5: ...c dissipative PVC desiccators should be periodically cleaned with clean lukewarm water and a clean nonabrasive cloth If desired a mild non abrasive detergent may also be used Use only light pressure when cleaning If the outside of the acrylic is exceptionally dirty or gritty rinse the surface first by lightly swabbing a saturated cloth over the surface and allowing surfactants to drain away Avoid ...

Страница 6: ...do not over tighten these or the desiccator walls will crack After replacing gaskets you may need to realign the desiccator doors refer to System Set Up Testing and Replacing Humidity Sensor If a discrepancy is observed between the displayed RH and that of an independent humidity calibrator the humidity scale can be compensated accordingly see Set Up instructions on page 2 The humidity sensor requ...

Страница 7: ... falling you may need to increase the flow from the nitrogen gas supply not to exceed 80 psi or use nitrogen of a higher purity 3 Check the door seals of the desiccator to make sure that there are no visible gaps The flexible gaskets are designed to allow a small amount of leakage in order to maintain a positive pressure environment PROBLEM The digital display is flashing open door EXPLANATION The...

Страница 8: ...o deliver an accurate reading contact Terra Universal 2 The fan inside the humidity controller is a key part of the system and must be running to ensure accurate RH readings The system will not provide correct readouts if the fan is not running 7 0Specifications Refer to the original order form for the exact specifications configuration of your desiccator NOTE Automatic RB Relief Bleed Valve Opera...

Страница 9: ...ately For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of concealed damage...

Отзывы: