Quick-Start Operating Guide
High- Ionizing Modules for Terra Desiccators
©
Copyright 2010 Terra Universal Inc. All rights reserved. • Revised Sept. 2010 • Document No. 1800-39
v2.0tm
Terra Universal, Inc. • TerraUniversal.com • 800 S. Raymond Ave. • Fullerton, CA 92831 • TEL: (714) 578-6000 • FAX: (714) 578-6020
3
Once connected to power, the Module immediately emits balanced streams of positive and negative ions through
each emitter pair. For effective ion distribution, make sure that the bar is installed in a gas flow of at least 50
feet/minute.
4.0
Maintenance
The Ionizing Module requires little maintenance beyond occasional cleaning. Frequency of cleaning depends on the
cleanliness of air in the immediate vicinity of the Module.
If deposits are observed on the emitter tips,
1.
Disconnect from system power.
2.
Use a cleanroom swab moistened with a cleaning solution of 50% isopropyl alcohol and 50% de-ionized water to
remove deposits from the emitter points.
3.
If deposits cannot be removed, or if the tips appear worn or bent, the Ionizing Module may not discharge
surfaces with optimal efficiency. In this case, replace the tips. Use a pencil eraser or needle-nosed pliers to
remove the old tip. Insert the new tip and gently press until it seats against the connector; no twisting is
necessary.
Cat. #
Replacement Titanium Emitters
2005-45
The emitter housing may be cleaned using alcohol or other mild detergent and de-ionized water.
5.0
Specifications
Emitter Points:
Replaceable machined titanium, 3-year estimated life (field replaceable)
Input Power:
24 VAC – order transformer separately: No. 2005-09A (110VAC) or No. 2005-09A-
220 (220VAC)*
Emitter output:
2,000 V (one each positive and negative); ± 50 V charge balance
Power Indicator:
Red LED
Ion Emission:
Steady-state DC, 104mA current draw (44" model)
Air flow:
50 fpm (.030 m/s) minimum required at bar for proper operation
Static Decay Time:
Discharge times directly under the IonBar™ average 28 seconds (from ± 1,000
volts to 100 volts), measured in a 4-foot laminar flow hood with air speed of 90
feet/minute.
Power Transformer*
Input Power:
120 VAC, 50/60Hz or 220VAC, 50 Hz
Output Power:
24 VAC, 1.0 Amp – drives up to 20 emitter pairs (low-voltage telephone cable, not
furnished, is required to interconnect IonBars)
Dimensions:
2.75" x 3" x 1.75"
Weight:
1
lb.
•
Power transformer included with Ionizing Fan Filter Unit and Glove Box Ionizing Module