3.0

 

Installation 

This unit is easy to install and use and requires little or no attention after the initial set-up. No special tools or 
mounting hardware is necessary for set-up; the platform comes completely assembled and ready for operation. 

NOTE:

   The platform is generally factory-adapted to suit particular application requirements. Your unit may or may 

not include plate weights, depending on your order and the loads you indicate the system will carry. The 
instructions in this section indicate both how to make the proper inflation settings and how to install or 

remove plate weights to suit your application. 

1. Connect your in-house gas supply to the quick-connect inlet located on the rear of the platform. To make this

connection, simply remove the collar from the end of the quick-connect fitting, press it onto the gas line, and then

screw it back onto the fitting. This fitting can then be pressed onto the platform inlet until it locks in place.

CAUTION:

 

You may need an external pressure regulator if line pressure in your in-house supply is greater 

than 100 psi. 

NOTE:  

The safety regulator is factory-set, and plate weights are installed in accordance with customer 

requirements before shipping. Under most circumstances, no further adjustment is required. Follow steps 2-

4 below only if you experience problems with any of these set-up conditions. 

2. Turn the platform over to expose the safety regulator located immediately inside the gas inlet. If your platform

incorporates a plate weight that covers the regulator, remove it (by removing the two set screws on the bottom of

the plate). If you have an electropolished stainless steel platform, you will need to remove the plastic bottom
cover.

3. This safety regulator should be set at no more than

60 psi to protect the isolators against the possibility
of overpressure. To make this setting, open the

four regulators located on the sides of the platform;

then open the safety regulator until the gauges (on

the front of the unit) read just under 60 psi. Lock

Isolator #3

Pressure
Gauge #1

Isolator #2

Regulator #2

Regulator #1

Isolator #1

Safety 
Regulator

Quick-Connect

Gas Inlet

Isolator #4

Regulator #3

Regulator #4

UNDERSIDE OF VIBRATION-FREE PLATFORM

WITH PLATE WEIGHTS REMOVED

Pressure
Gauge #1

Pressure
Gauge #1

Pressure
Gauge #1

Front

M-31

UNDERSIDE OF VIBRATION-FREE PLATFORM

WITH PLATE WEIGHTS

M-32

Vib rat or
Isol a tor

Bottom  W eight (39 lbs.)

W eight #1 (55 lbs.)

V ib r at or
Isol at or

Содержание 1580-03

Страница 1: ...art Operating Guide Vibration Free Platform Copyright 2010 Terra Universal Inc All rights reserved Revised October 2010 Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Страница 2: ...ntal over pressures that can lead to the blow up of isolators CAUTION For best results Terra recommends that the Vibration Free Platform be operated with continuous line pressure applied to the safety regulator Proprietary Notice This manual pertains to proprietary devices manufactured by Terra Universal Inc Neither this document nor any portion of it may be reproduced in any way without prior wri...

Страница 3: ...ernal pressure regulator if line pressure in your in house supply is greater than 100 psi NOTE The safety regulator is factory set and plate weights are installed in accordance with customer requirements before shipping Under most circumstances no further adjustment is required Follow steps 2 4 below only if you experience problems with any of these set up conditions 2 Turn the platform over to ex...

Страница 4: ... the net weight of the unit This additional weight will provide more effective attenuation of the vibration frequency to which your system is exposed If you must alter the plate weights be sure to deflate the isolators before removing the load 6 Plate weights are secured to the platform by means of the two hex screws located in the top center and bottom of the unit The top two screws attach the fi...

Страница 5: ...Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 5 4 0Specifications Plate Weights 55 lbs and 39 lbs Note Load must be placed atop platform before inflating isolators Maximum inflation pressure must not exceed 40 psi Isolators must be deflated before removal of load Platform Material 304 Stainless steel electropolished Air Inlet Quick connect disconnect for 1 4 diameter nylon tubin...

Страница 6: ...eparately For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of concealed da...

Отзывы: