PRODUCT DESCRIPTION

SAT multichannel amplifiers (in text - amplifier) SA91L, SA91DL are parts of medium or large SMATV networks. 

SA91L is designed as a launch amplifier and usually is installed at the begining of network. Its main purposes are: 

- to equalize the power of signals in different lines; 

- to make amplitude pre-correction of signal for compensation its loss in network; 

- to supply voltage to LNB converters and other network elements like interstage amplifiers SA91DL, MV series multiswitches, 

terrestrial path amplifiers and so on. 

Terrestrial TV input has LTE signal suppression filter 

.

SA91DL is designed as interstage amplifier with remote powering. Generally it is installed inside cascaded type networks 

to compensate signal loss in trunk lines. It could be used as a launch amplifier if additional power supply is plugged to relative 

connector. 

The housing of amplifiers meets more stringent screening requirements according to EN50083-2, class A.

According to the standard ETSI EN 303 354 V.1.1.1, this TERR TV band amplifier type is Launch, selectivity clasification 0.

The amplifiers are intended for indoor use only.

SAFETY INSTRUCTIONS

Installation of the amplifiers must be done according IEC60728-11 and national safety standards. 

Amplifier SA91L is powered from mains 230 V~ (this voltage is dangerous to life) and SA91DL - from line 12...20 V DC 

through input connectors or auxiliary DC input. 

Any repairs must be done by a skilled personnel. 

Amplifier SA91L is double isolated from mains 230 V~. 

To avoid the electric shock follow these instructions: 

Do not remove the cover of the power supply section, without disconnecting the amplifier from the mains supply. 

Do not plug the amplifier into the mains supply if the power cord or plug is damaged. 

Do not plug the amplifier SA91L into the mains supply until all cables have been connected correctly. 

The mains socket must be easily accessible. 

Avoid placing amplifier next to central heating components, near highly combustible materials and in areas of high humidity. 

If the amplifier has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging 

into the mains. 

Do not insert any objects into ventilation openings. 

The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, 

curtains. 

Mount the amplifier on not flammable wall or in not flammable installation box in vertical position (SA91L) with power supply 

unit on the right side. Mount in locations where children not likely to be present. Shields of cables must be connected to main 

potential equalization bus.

The 

amplifier must be fixed with steel screws Ø 4-5 mm. The screws are not included in a package.

From top, front and bottom of installed amplifier must be at least 10 cm free space.

Содержание SA91L

Страница 1: ...ins 230 V this voltage is dangerous to life and SA91DL from line 12 20 V DC through input connectors or auxiliary DC input Any repairs must be done by a skilled personnel Amplifier SA91L is double isolated from mains 230 V To avoid the electric shock follow these instructions Do not remove the cover of the power supply section without disconnecting the amplifier from the mains supply Do not plug t...

Страница 2: ...in controls Slope controls Functional grounding clamp Inputs Outputs 12V switch and indicator 14V switch and indicator 18V switch and indicator Mounting supports Mounting supports Mounting supports Mounting supports A H Lo A H Lo B H Lo B H Lo 18V 18V 14V 14V 14V 14V 18V 18V A H Hi A H Hi B H Hi B H Hi A V Lo A V Lo B V Lo B V Lo A V Hi A V Hi B V Hi B V Hi Terr TV Terr TV Slope dB Slope dB Slope ...

Страница 3: ...ifier SA91DL is powered from central network power supply for example SA91L through horizontal polarization lines Both lines regarding DC are interconnected to minimize voltage loss in lines It consumes up to 0 3 A from 18 V power supply Amplifier has connector for auxilary power supply if voltage from central power supply is not accessible If it is plugged voltage is distributed to horizontal pol...

Страница 4: ...02 96 EC The unit must be recycled or discarded according to applicable local and national regulations The device has integrated LTE filter Equipment intended for indoor usage only Equipment is double insulated from the mains with functional earthing Functional earthing Connect to the main potential equalization This product is in accordance to following norms of EU EMC norm EN50083 2 safety norm ...

Страница 5: ...h elementów pasywnych zdefiniowanej w normie EN50083 2 Zgodnie ze standardem ETSI EN 303 354 V 1 1 1 typ wzmacniacza Launch klasyfikacja selektywności 0 INSTRUKCJE BEZPIECZEŃSTWA Montaż urządzeń powinien odbywać się zgodnie z obowiązującymi standardami bezpieczeństwa oraz być wykonywany przez wykwalifikowany personel Wzmacniacz SA91Lzasilany jest napięciem zmiennym 230 V Napięcie to jest niebezpie...

Страница 6: ... przełącznik i wskaźnik Regulacja wzmocnienia Korekcja ch ki tłumienia przewodu Podpory montażowe Podpory montażowe Podpory montażowe Podpory montażowe A H Lo A H Lo B H Lo B H Lo 18V 18V 14V 14V 14V 14V 18V 18V A H Hi A H Hi B H Hi B H Hi A V Lo A V Lo B V Lo B V Lo A V Hi A V Hi B V Hi B V Hi Terr TV Terr TV Slope dB Slope dB Slope dB Slope dB Slope dB Slope dB Slope dB Slope dB Slope dB Att dB ...

Страница 7: ... wzmocnienia dla najwyższych większe wzmocnienie i najniższych mniejsze wzmocnienie częstotliwości Wzmacniacz SA91L zapewnia zasilanie 18 V na wszystkich liniach sygnałowych polaryzacji poziomej 14V na wszystkich liniach polaryzacji pionowej oraz 12 V w torze wejściowym telewizji naziemnej Przełączniki umieszczone po stronie wyjść pozwalają na włączanie oraz wyłączanie napięcia na wyjściach urządz...

Страница 8: ...nas Lithuania tel 370 37 31 34 44 fax 370 37 31 35 55 E mail sales terraelectronics com http www terraelectronics com SCHEMAT PRZYKŁADOWEJ INSTALACJI MV916L Ground Floor 1st Floor 2nd Floor MV912L SA91DL SD910 SD910 SD910 MV908L SA91L ...

Отзывы: