The basic configuration of the thermostat includes setting the time and date (in the form of the number 

of the day of the week), and selecting the operation mode from the available 3 modes: manual, automa-

tic and holiday mode.

Setting the time and date is done with the thermostat switched on. Hold the button       pressed for at 

least 3 seconds and then use the buttons           to select option 01 and confirm the selection by pres-

sing the button      . Minute, hour and day of the week are selected by an approval to be edited of the 

successive variables by pressing the button       in order to edit the selected variable and confirm the 

selection, as well as by pressing the buttons             . Programming the schedule is also performed with 

the thermoregulator switched on. Press and hold the button        for at least 3 seconds, then use the but-

tons              to select option 02 and confirm by pressing the button       . The next program – a time period 

of day, minutes, hours - is selected by means of approving for editing, as well as by pressing the button in 

order to edit the selected variable and approving it upon setting the proper value using the buttons          .

OPERATING AND CONFIGURATION MANUAL 

FOR THE THERMOFOL TF-H6 THERMOSTAT

CHARACTERISTICS AND TECHNICAL DATA

Thank you for purchasing our product. We hope that you will enjoy using the TERMOFOL TF-H6 ther-

moregulator. It is a fully functional controller of installations and heating devices providing the highest 

comfort of use, as well as precise and useful functions that will allow you to fully control the climate in 

your rooms. The display of the thermoregulator and its basic technical parameters are presented below.

Supply voltage: 240V AC 50/60 Hz • Colour: White • Built-in air temperature sensor: NTC • External floor air temperature 
sensor: NTC (optional) • Maximum switched amperage: 16A • Programmable temperature range: 1÷70 °C • Factory 
programmed temperature range: 5÷35 °C • Accuracy: ±0.5 °C • External dimensions (without frame): 55 mm x 55 mm • 
External dimensions (with frame): 82 mm External dimensions (with frame): 82 mm x 82 mm (modular system available) 
• IP31 

THERMOSTAT INSTALLATION, ELECTRIC CONNECTIONS

The TERMOFOL TF-H6 is a modern, programmable thermoregulator with LED control panel intended 

for controlling electric heating systems. Thermoregulator works with a built-in NTC temperature sensor 

and an external floor NTC temperature sensor, which is included in the kit along with the thermoregu-

lator. Prior to its installation, disassembly, cleaning, inspection or change of the configuration, always 

disconnect the thermoregulator from the power source, e.g., by switching off the power line in the elec-

tric switchboard. Read the entire contents of this manual before installing the thermoregulator. In the 

territory of the Republic of Poland, the electric connections of the thermoregulator should be made by 

an electrician holding a valid SEP license for electric installations up to 1 kV. The electric installation sup-

plying the thermoregulator should meet the requirements specified in the Regulation of the Minister of 

Infrastructure and Construction on technical conditions to be met by buildings and their location (Journal 

of Laws of 7 June 2019, item 1065) along with reference.

Figure 1. Description of the thermoregulator terminal block

Figure 2. Disassembly of the thermoregulator

The thermoregulator is designed for the installation in a 60 mm electric installation box. For the purpose 

of the installing, it in the installation box and making the electric connections, you should open its ho-

using very gently (so as not to break the connection tape) by removing the display unit according to the 

instructions in Figure 2 above. The installation of the thermoregulator should be planned in a place not 

exposed to the sunlight. Figure 1. shows the thermoregulator terminal block used to make the electric 

connections. The power supply line of the thermoregulator is connected to the terminals of the ther-

moregulator terminal block. The neutral wire (N) of the power supply line is connected to the terminal 

marked with number 2, and the phase wire (L) to the terminal marked with number 1. The heating device 

(heating mat, heating film) is connected to the terminals of the terminal block respectively, the neutral 

wire (N1) of the heating device power supply line is connected to the terminal marked with number 3. 

The external floor NTC temperature sensor should be connected to the terminals marked with numbers 

6 and 7, where the polarity is irrelevant. Upon completing the installation and making the electric con-

nections, configure the system according to the next section of this manual.

CONTROLLING – DESCRIPTION OF FUNCTIONS OF CONTROL BUTTONS

The graphic identification of the thermoregulator control panel buttons (display) is presented below. 

These buttons are multifunctional, i.e., depending on the operating status of the thermoregulator, and 

by varying the duration of the touch, it is possible to give various commands to the thermoregulator. 

The description of the buttons and the thermoregulator functions available with their use can be found 

below. 

Power ON/OFF button. In the thermostat off state, touching this button switches the thermo-

stat on. In the operating state of the thermostat, touching it displays the clock on the display of 

this device. In order to turn the thermostat off, touch this button for at least 3 seconds.

Menu button is used to change the operating mode of the thermoregulator from the manual to 

automatic schedule mode or holiday mode and vice versa while the thermostat is operating. If 

the thermoregulator operates in the holiday mode or automatic schedule mode, touching this 

button enables the manual mode and the possibility of changing the set air temperature. In the 

operating status of the thermoregulator touching this button and holding down the button for 

at least 5 seconds allows for enabling of the clock and date correction and schedule program-

ming functions. In this case the button is also used to confirm individual changes and schedule 

parameters. When the thermoregulator is switched off, touching this button and holding the 

touch for minimum 5 seconds activates the wizard of advanced functions of the thermoregu-

lator.
Cursor button for dialling down. When the thermoregulator is switched on, touching and hol-

ding it down for more than 3 seconds switches the child lock on and off. A single touch causes 

that the temperature level set in the manual mode is displayed and repeated touches decrease 

its value.

Cursor button for dialling up. When the thermoregulator is switched on, touching and holding 

down for more than 3 seconds makes it possible to have a read-out of the temperature measu-

red by an external floor NTC temperature sensor. A single touch displays the temperature level 

set in the manual mode, and repeated touches increase its value.

When the thermoregulator is operating in automatic schedule mode, the buttons                     allow for 

 

a temporary temperature correction for the current period of the automatic schedule of the thermostat.

DISPLAY ICONS – SPECIFICATION 

con with the numbers from 1 to 6 indica-

tes  the  currently  operated  programme 

(period of one day and night -24 hrs.)
icon  indicating  the  current  day  of  the 

week within the range from 1 to 7

icon indicating enabling the child lock

icon  indicating  enabling  the  anti-freeze 

function

cons  indicating  the  operation  of  the 

thermoregulator  in  a  temporary 

mode within the current mode

icon confirming the thermostat opera-

tion in the automatic schedule mode

icon confirming the thermostat opera-

tion in the manual mode

icon  confirming  power  supply  to  the 

heating device by the thermostat
icon  indicating  enabling  the  holiday 

mode

icon  indicating  the  thermostat  opera-

tion in the holiday mode

CONFIGURATION OF BASIC PARAMETERS (TIME, OPERATION MODE)

1

IP31

2

3 4

5

6

7

P1

P2

P3

P4

P5

P6

Wake - up

Leaving home

Returning home

Leaving home

Returning home

Sleep

6:00

20 °C

8:00

15 °C

11:30

15 °C

13:30

15 °C

17:00

15 °C

22:00

15 °C

The holiday mode is enabled when the thermoregulator is turned on. Press and hold the button        down 

for at least 3 seconds, then use the buttons             to select option 03 and confirm the selection by pres-

sing the button        . The selection of days and temperature assigned to them is made by approving for 

editing the successive variables, as well as by pressing the button         to edit the selected variable and 

confirming it upon setting the appropriate value using the buttons              .

PROGRAMMING OF ADVANCED OPTIONS OF THERMOSTAT

The  table  below  lists  the  advanced  functions  and  programmable  parameters  of  the  thermostat.  For 

the purpose of getting an access the advanced settings, turn off the thermostat by pressing the but-

ton        for more than 3 seconds. Then hold the button        down for a minimum of 5 seconds until the 

thermostat screen is illuminated. Single touches of the button        switch between successive functions/

parameters and modification of the value of a given function/parameter is made using the buttons            . 

Moving to the next function/parameter saves the settings of the preceding one.

No.

Type of function / parameter

Range of parameter value / function option

Factory 

value

1

Calibration of air 

 

temperature sensor

-9 °C ÷ 9 °C

-1 

°C

2

Hysteresis of air 

 

temperature sensor

0,5 °C ÷ 2,5 °C

1 °C

3

Hysteresis of external floor 

temperature sensor

1 °C ÷ 9 °C

2 °C

4

Selection of temperature sen-

sors – Selection temperature 

control method

N1: only built-in temperature sensor is ON only. 

 

N2: only external floor temperature sensor is ON. 

 

N3: built-in and external floor temperature sensors are ON 

– maintaining the set air temperature with control of the 

heating device temperature

N3

5

Button locking

0: partial locking / 1: full locking

0

6

Limitation of maximum tempe-

rature of external floor sensor

20 °C ÷ 70 °C Note: setting a value below 20 °C will disable 

this function!

29 °C

7

Limitation of minimum air 

temperature

1 °C ÷ 10 °C Note: setting a value above 10 °C will disable 

this function!

5 °C

8

Minimum value of programmed 

temperature

1 °C ÷ 10 °C

5 °C

9

Maximum value of program-

med temperature

20 °C ÷ 70 °C

35°C

A

Decalcification function 

 

(for water boilers)

0: enabled / 1: disabled

0

B

Memory function of device 

status prior to a power supply 

failure

0: Device restores its state prior to a power failure 

 

1: Device remains OFF after power supply returns 

 

2: Device remains ON after power supply returns

0

C

Type of automatic operation 

schedule (by weekdays)

0: 5+2 days / 1: 6+1 days / 2: 7 days

0

D

Sleep mode – configuration 

 

of display parameters

0: nothing is displayed in standby mode

 

1: temperature is displayed in standby mode

 

2: temperature is displayed – higher brightness in standby 

mode

2

E

Restoration of factory settings

Hold down the button       for more than 5 seconds after 

selecting this option

Ao

F

Open window detection 

 

function (range of temperature 

function enable)

10°C ÷ 20 °C

10 °C

H

Period of execution open 

 

window detection function

10 min ÷ 20 min

10 min

P1

Power consumption of 

 

previous day

XXXX Kwh, long press           to clear the data

P2

Total power consumption

XXXX Kwh, long press           to clear the data

P3

Rate power of heating device

XXXX W,  Setting range: 100-3500W

2000W

P4

Modbus IP communication 

address

01~FF

01

P5

Modbus communication 

 

baud rate

0: 2400 1: 4800 2: 9600

0

Hysteresis of the external floor sensor – additional information: the limit of temperature value measured 

by the external floor sensor is of 29 °C for the factory setting of advanced options (section 6), and the fac-

tory value of external floor sensor hysteresis (section 3) is of 2 °C. When the temperature rises to 29 °C, 

the thermostat stops supplying the controlled heating device and reminds you of the high temperature 

alarm by displaying the flashing symbol       .  If the temperature measured by the external floor sen-

sor decreases to 27 °C, the thermostat will start supplying the controlled heating device again and the 

symbol        will stop flashing (only if the air temperature in the room is lower than the set temperature).

Error codes 

displayed by the thermostat. A correct configuration of the built-in and external floor tem-

perature sensors must be provided according to section 4 related to the advanced options. An incorrect 

selection or a sensor malfunction (failure) will cause an error message to be displayed on the screen. 

Displaying the message with the following content: ‘E1’ means a malfunction of the built-in temperature 

sensor, while displaying a message of the following content ‘E2’ means that the external floor tempera-

ture sensor has failed. The thermostat will not supply power to the controlled heating device until the 

fault has been rectified!

Turn on thermostat, long press          +           to query the Modbus IP address

Turn off thermostat, long press          and          to enter advance option P. Short press          to choose item, short press     

 

            or           to change the value.