ErP
Information requirement for the electric local space heaters
Models: TF-CS500
Item
Sign
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage
local space heaters only(Select one)
Nominal heat output
Pnom
0,5
kW
manual heat charge control,
with integrated thermostat
No
Minimum heat out
-
put(indicative)
Pmin
0,0
kW
manual heat charge control
with room and/or outdoor
temperature feedback
No
Auxiliary electricity consumption
fan assisted heat output
No
At nominal heat
output
elmax
0,5
kW
Type of heat output/
room temperature
control(select one)
At minmum heat
output
elmin
0,0
kW
Single stage heat output
and no room temperature
control
No
In Standby mode
elSB
0,001
kW
two or more manual stages,
no room temperature
control
No
with mechanic thermostat
room temperature control
No
with electronic room tempe
-
rature control
No
electronic room temperature
control plus day timer
No
electronic room temperature
control plus week timer
Yes
Other control options(mul
-
tiple selection possible)
room temperature control, with
presence detection
No
room temperature control,
with open window detec-
tion
Yes
with distance control option
No
with adaptive start
No
with working time limitation
No
with black bulb sensor
No