![Termodinamik EKY 100 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/termodinamik/eky-100/eky-100_installation-and-usage-manual_1089223020.webp)
EKY DIGITAL CONTROL PANEL
KEYS
1.ENTER
Used for confirming the values
entered in the appliance.
2.ESC
Used for canceling the operation of the
new value entered in the appliance and
returning to the previous value in the
memory.
3.UP/DOWN KEYS
Used to enter new values in
the appliance.
4.TEMPERATURE SETTINGS
Used for setting the boiler temperature
setting.
ELECTRICAL CONNECTION
1
2
3
4
5
6
7
17
If the shaft is made of iron sheet material, insulate the surrounding of the shaft and prevent
the heat loss.
The shaft should not have a sectional narrowness at any spot.
Make sure not to install another appliance or more than one boiler to the same shaft.
The boiler should not be installed to the shaft at a reverse angle preventing draught (see
page 16).
The shaft should be periodically cleaned not allowing for the formation of tarry soot
inside which makes it impossible to clean the shaft.
The flue pipe (chimney) mustn
’
tbe mounted with level which prevent the drought of it.
End of the chimney must be 40 cm higher than tip of the roof.
Chimney should be well insulated and heat losses should be reduced. When the chimney
cools down the draught also decreases and in the cooled chimney the formed acids
combined with the effect of condensation can lead corrosion on the inner surfaces of the
chimney or down inside the boiler, therefore chimneys should also be insulated.
The electrical connections should be performed by the technical service. The connections
should be performed as shown in the pages 22, 24 and 25. In case of damages resulting from
different connection or the arbitrary change of the thermostats, the manufacturer cannot be
held liable.
H E A T I N G S Y S T E M S
Содержание EKY 100
Страница 4: ...EKY 17 100 TECHNICAL SPECIFICATIONS 1 H E A T I N G S Y S T E M S D C G F E EKY 17 SIDE VIEW ...
Страница 6: ...EKY 125 250 TECHNICAL SPECIFICATIONS 3 H E A T I N G S Y S T E M S 338 mm 365 mm ...
Страница 8: ...EKY 125 500 3 BAR TECHNICAL SPECIFICATIONS 5 H E A T I N G S Y S T E M S ...
Страница 10: ...EKY 125 1000 5 BAR TECHNICAL SPECIFICATIONS CHART 7 H E A T I N G S Y S T E M S ...
Страница 35: ......