Страница 1: ...CS 70 85 100 150 200 250 300 350 400 500 600 700 800 900 1000 ECS STEEL BODY CENTRAL HEATING HOT WATER BOILER CALOR SRL Str Progresului nr 30 40 sector 5 Bucuresti tel 021 411 44 44 fax 021 411 36 14 www calorserv ro www calor ro ...

Страница 2: ... 2 Shaft exit temperature range o C 170 195 170 195 170 195 170 195 170 195 MODELS Unit ECS 250 ECS 300 ECS 350 ECS400 ECS 500 Heat power kcal h 250 000 300 000 350 000 400 000 500 000 kW 290 6 348 7 406 8 464 9 581 1 Heat input kcal h 274 700 329 700 384 600 439 600 549 500 kW 319 3 383 2 447 510 9 638 6 Max Operating Temperature o C 105 105 105 105 105 Temperature control range o C 30 90 30 90 3...

Страница 3: ...ture o C 105 105 105 105 105 Temperature control range o C 30 90 30 90 30 90 30 90 30 90 Firing chamber pressure mbar 5 3 5 9 6 4 7 7 5 Max Operating pressure bar 5 5 5 5 5 Test Pressure bar 7 5 7 5 7 5 7 5 7 5 Boiler water capacity lt 846 969 1232 1306 1446 Shaft diameter mm 300 300 350 350 350 Firing chamber dimensions 738 738 820 820 820 L 1583 1853 1776 2015 2265 Input Output Water Connections...

Страница 4: ...GENERAL DIMENSIONS AND TECHNICAL SPECIFICATIONS ...

Страница 5: ... 194 420 200 R2 R1 1 4 R3 4 5 7 5 232 460 200 R2 R1 1 4 R3 4 5 7 5 307 510 220 R2 1 2 R1 2 R3 4 5 7 5 433 775 220 R2 1 2 R1 2 R3 4 5 7 5 454 860 220 R2 1 2 R1 2 R3 4 5 7 5 454 860 220 R2 1 2 R1 2 R3 4 5 7 5 510 935 250 R3 R2 R3 4 5 7 5 633 1350 250 R3 R2 R3 4 5 7 5 791 1485 300 R3 R2 R3 4 5 7 5 846 1590 300 R3 R2 R3 4 5 7 5 969 1710 350 R4 R2 1 2 R3 4 5 7 5 1232 2030 350 R4 R2 1 2 R3 4 5 7 5 1306 ...

Страница 6: ...which generates water at maximum 90 C for heating purposes Thanks to its three pass design the heat generated as a result of burning the fuel is transferred to heat transfer fluid and the heat loader decreases thanks to heat transfer surface and the life span of the boiler increases Since the amount of NOX found in the smoke reaching to the shaft under lower temperatures decreases in parallel with...

Страница 7: ...liance There are arcing and sparking parts in the boiler and burner Please do not store blasting and flammable liquids and gasses in the boiler room Make sure to operate your appliance using only a grounding plug If the power cable or other electric connections are damaged do not operate the boiler Improper installation and not performing the routine maintenances may result in injuries and even fa...

Страница 8: ...r than air e g LPG make sure to take additional precautions In case of any fuel leakage please use systems that allow for the discharge of such fuel from the boiler room and automatically cuts the fuel feeding Please consider that waters with high hardness levels will cause calcification Malfunctions and decreased performance due to calcification Problems resulting from the use of appliance in dif...

Страница 9: ...e Installation 1 Central System Turning 2 Central System Going 3 Safety Line 4 1 st Circulation Pump 5 2 nd Circulation Pump Extra 6 Expansion Tank 7 Valve for the 1 st Pump 8 Valve for the 1 st Pump 9 Valve for the 2 nd Pump 10 Valve for the 2 nd Pump 11 Filling Valve ...

Страница 10: ...ystem Turning 2 Central System Going 3 Safety Going 4 1 st Circulation Pump 5 2 nd Circulation Pump Extra 6 Expansion Tank 7 Valve for the 1 st Pump 8 Valve for the 1 st Pump 9 Valve for the 2 nd Pump 10 Valve for the 2 nd Pump 11 Filling Valve 12 Fittings 13 Safety Turning 14 Messenger Pipe ...

Страница 11: ...ly Make sure you do not hit the ground or pallet with the boiler and do not drop the boiler Check the foot levels of the boiler If necessary adjust the levels of the feet Do not replace the feet completely MODEL Minimum Ground Sizes ECS 70 1080 X 960 X 200 mm ECS 85 1080 X 960 X 200 mm ECS 100 1080 X 1110 X 200 mm ECS 150 1080 X 1400 X 200 mm ECS 200 1210 X 1400 X 200 mm ECS 250 1210 X 1530 X 200 ...

Страница 12: ...nimum The shaft should be isolated against condensation The entire system shaft electric water fuel should be checked against leaks following the assembly The entire weight of the big and heavy burners should be lifted by well adjusted supports instead of the boiler s front lid Check for gas leaks before turning on the boiler if you suspect there might be a leak do not turn on the boiler before re...

Страница 13: ...urn on the fuel line Turn on the main power supply When the Burner Indicates Malfunctioning Before Calling the Authorized Service Ensure The system is able to receive power Minimum gas pressure is available Fuel valves are on The system s water level and the pressure are at normal levels If the system operates using liquid fuel the boiler heat transfer surfaces should be cleaned at least once a mo...

Страница 14: ...ions Check the electrical connection cables Make sure the connections are secured Safety fuse Make sure a proper safety fuse connection is established Test the operation of the fuse On off switches and Plugs Check the compatibility of on off switches and plugs and if they are functional Smoke and CO Detector Make sure this appliance is installed and properly functions If necessary replace its batt...