                                                                               IO-752:2018/EN                                                    05.12.2018 

 

2. PRODUCT DESCRIPTION  

2.1. Technical features 

 

Electronic ignition with a ionisation flame control  

 

Lack of chimney draught protection and fumes 
leak protection. 

 

Heat exchanger overheating protection. 

 

Proportional power regulation. 

 

Device adapted for water supply system from 20 to 
1000 kPa (0,2 to 10,0 bar) 

 
Gas  instantaneous  water  heaters  type  GE-19-02  and 
GH-19-02  are  manufactured  as  B

11BS

  installation  type 

version,  what  means  that  they  are  intended  to  be 
connected  to  the  individual  flue  chimney.  Combustion 
products are taking out of the room by means of natural 
draught.  The  air  for  the  combustion  process  is  being 
taken  directly  from  the  room  where  the  water  heaters 
are  installed.  Water  heaters  are  equipped  with  a 
protection  against  draught  loss  in  a  flue  pipe  and 
protection against fumes escape into a room. 
 
The  water  heaters  GE-19-02  and  GH-19-02  are 
equipped with the most recent technical solutions which 
provide 

long-lasting, 

faultless 

and 

economic 

performance and the comfort of use.

 

 
The  fittings  used  in  the  water  heaters  ensure 
proportional  power  regulation,  which  enables  to  get 
constant temperature of outflowing water. 
 
Activation  (burner  ignition)  of  the  water  heater  takes 
place  with  each  opening  of  the  tap.  Shutdown  takes 
place after closing the tap. 
 
One of the main advantages of the water heaters is little 
water  flow  necessary  to  start  up  the  appliance

 

(about 

3,2 l/min).

 

 
Each water heater is destined to combust only one type 
of gas (for example 3B-G30) and the water heater must 
be fed only with this type of gas.

 

 
The water heater’s type, the group and type of gas, as 
well as the service line pressure which the water heater 
was designed for, are marked on the packaging, in the 
instruction manual and on the marking plate. 
 
The  water  heater  can  be  converted  to  another  type  of 
gas only by an Authorized Service Center in accordance 
with point 5. 
 
 
 
 
 
 
 
 
 
 

2.2. Water heater construction and 

technical data  

2.2.1.  Main components  

of the water heater 

Temperature limiter as protection against overheating 
of the heat exchanger  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig. 2.2.1.1 Main components of the water heater

1  Burner 
2  Electrode set 
3  Water-gas fittings 
4  Heat exchanger 
5  Draught breaker 
6  Spark generator 
7  Battery compartment 
8  Temperature limiter - protection against flue gas 

outflow into the room  

6      7 


 

 
 
 
 



 

Содержание TERMAQ AQUA-POWER ECO GH-19-02

Страница 1: ...TA 1450 012 12 INSTALLATION AND OPERATION MANUAL Instantaneous gas water heater...

Страница 2: ...ndards Please take time to get yourself familiarised with this manual as full understanding of the product s functions as well as knowledge of manufacturer s recommendations is imperative for its smoo...

Страница 3: ...8 4 WATER HEATER OPERATION 8 4 1 Preparing the water heater for the first start up 8 4 2 Water heater starting up 9 4 3 Water temperature and water flow regulation 9 4 4 Water heater switching off 10...

Страница 4: ...ater can be operated only by adults Do not perform any repairs or alterations to the water heater on your own It is strictly forbidden to make any modifications that could reduce the clearance of air...

Страница 5: ...ters ensure proportional power regulation which enables to get constant temperature of outflowing water Activation burner ignition of the water heater takes place with each opening of the tap Shutdown...

Страница 6: ...ential pressure valve 3 5 1 Coil I of the differential pressure valve 3 5 2 Coil II of the differential pressure valve 3 6 Regulating screw of the microswitch 3 7 Regulating screw of the little water...

Страница 7: ...perature in the heat exchanger exceeds 950C by cutting off the voltage in the supply system and also closing the gas supply to the burner It is forbidden to make any modifications in the water heater...

Страница 8: ...ater heater is installed there should be a non closing hole of exhaust ventilation with the surface not smaller than 200 cm2 placed as close to the ceiling as possible It is not allowed to use mechani...

Страница 9: ...g significant difficulties for a service team on a wall made of non flammable materials or isolated from an inflammable wall with a plate made of non flammable material In case of building the water h...

Страница 10: ...irst start up Before proceeding with the first start up of the water heater it is necessary to Fill the water system with water so as after turning on the water taps water may flow This ensures that t...

Страница 11: ...rning off the hot water tap the gas supply to the burner will be cut off 4 3 Water temperature and water flow regulation Water heaters are equipped with modern gas water fittings ensuring proportional...

Страница 12: ...ssions Gas type CO emissions ppm 1 2E G20 58 5 3P G30 48 4 3B G30 48 4 3P B G31 490 155 1 CO concentration for maximum gas pressure Pmax 5 2 Gas consumption values Gas type Range of kinetic gas pressu...

Страница 13: ...such case the fittings should be taken out the water heater Then take out the filter clean it and assembly again Fig 5 4 1 Fig 6 4 1 Water gas fittings 6 4 Safety system checking During every inspecti...

Страница 14: ...uctions 1 Check the correctness of electric connections 2 Connect a voltmeter to the pole In TERMAQ ELECTRONIC ECO water heaters spring in battery compartment item 6 In TERMAQ AQUA POWER ECO water hea...

Страница 15: ...out the whole burner Control electrode wire is disconnected Correct the connection Damaged control electrode Check replace Damaged spark generator Check replace Damaged differential pressure valve Che...

Страница 16: ...et to water gas fittings is damaged Replace gasket with a new one One of the gaskets on the outlet from water gas fittings or on the inlet to burner is damaged Replace gasket with a new one Water gas...

Страница 17: ...IO 752 2018 EN 05 12 2018 D uga 13 58 160 wiebodzice Infoline 48 74 856 08 01 48 74 854 68 90 http www termet com pl export termet com pl termet termet com pl...