![TERMET TERMAQ AQUA-POWER ECO GH-19-02 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/termet/termaq-aqua-power-eco-gh-19-02/termaq-aqua-power-eco-gh-19-02_installation-and-operation-manual_1089164005.webp)
IO-752:2018/EN 05.12.2018
3
2. PRODUCT DESCRIPTION
2.1. Technical features
•
Electronic ignition with a ionisation flame control
•
Lack of chimney draught protection and fumes
leak protection.
•
Heat exchanger overheating protection.
•
Proportional power regulation.
•
Device adapted for water supply system from 20 to
1000 kPa (0,2 to 10,0 bar)
Gas instantaneous water heaters type GE-19-02 and
GH-19-02 are manufactured as B
11BS
installation type
version, what means that they are intended to be
connected to the individual flue chimney. Combustion
products are taking out of the room by means of natural
draught. The air for the combustion process is being
taken directly from the room where the water heaters
are installed. Water heaters are equipped with a
protection against draught loss in a flue pipe and
protection against fumes escape into a room.
The water heaters GE-19-02 and GH-19-02 are
equipped with the most recent technical solutions which
provide
long-lasting,
faultless
and
economic
performance and the comfort of use.
The fittings used in the water heaters ensure
proportional power regulation, which enables to get
constant temperature of outflowing water.
Activation (burner ignition) of the water heater takes
place with each opening of the tap. Shutdown takes
place after closing the tap.
One of the main advantages of the water heaters is little
water flow necessary to start up the appliance
(about
3,2 l/min).
Each water heater is destined to combust only one type
of gas (for example 3B-G30) and the water heater must
be fed only with this type of gas.
The water heater’s type, the group and type of gas, as
well as the service line pressure which the water heater
was designed for, are marked on the packaging, in the
instruction manual and on the marking plate.
The water heater can be converted to another type of
gas only by an Authorized Service Center in accordance
with point 5.
2.2. Water heater construction and
technical data
2.2.1. Main components
of the water heater
Temperature limiter as protection against overheating
of the heat exchanger
Fig. 2.2.1.1 Main components of the water heater
1 Burner
2 Electrode set
3 Water-gas fittings
4 Heat exchanger
5 Draught breaker
6 Spark generator
7 Battery compartment
8 Temperature limiter - protection against flue gas
outflow into the room
6 7
8
5
4
2
1
3
7