7
3. All installations to which the device is connected should comply with
the regulations applicable in the country of installation and use.
4. It must be ensured that the circuit in the electrical installation to
which the radiator is connected has an appropriate overcurrent cir-
cuit breaker and a residual current device (R.C.D.) with a sensitivi
-
ty of 30 mA. With the permanent (hard-wired) installation it is also
mandatory to have an omni polar cut-off for disconnecting the de
-
vice on all poles, by points of contact with the clearance of 3 mm.
5. The device version labelled PB can be installed in bathrooms, but
at
least 1m from any water source, PW version with the plug can be
installed in dry areas only, (as defined by applicable law, subject to
any additional regulations concerning electrical installations in wet
areas).
6. Do not use extension cords or adapters for electrical outlets to plug
the product.