71M6521 Demo Board User’s Manual
Page: 40 of 111
© 2005-2009 TERIDIAN Semiconductor Corporation
Revision 2.18
Name
Purpose
Function or LSB Value
CLI
Format
L in
bits
XDATA
Vrms_B
Vrms, element B**,†
SQSUM
V
1
2
16
)25
unsigned
32
0x0053
Irms_B
Irms, element B
SQSUM
I
1
2
16
)27
unsigned
32
0x0057
STATUS
Status of meter
See table for STATUS register
)2A
unsigned
32
0x0063
CAI
Count of accumula-
tion intervals since
reset, or last clear.
count
)28
signed
32
0x0067
Whi**
Imported Wh, all
elements.
LSB of W0SUM
)2C
signed
64
0x006B
Whi_A**
Imported Wh,
element A
“
)2E
signed
64
0x0073
Whi_B**
Imported Wh,
element B
“
)30
signed
64
0x007B
VARhi*
Imported VARh, all
elements.
LSB of W0SUM
)34
signed
64
0x008B
VARhi_A*
Imported VARh,
element A
“
)36
signed
64
0x0093
VARhi_B*
Imported VARh,
element B
“
)38
signed
64
0x009B
VAh**
VAh, all elements.
LSB of W0SUM
)3C
signed
64
0x00AB
VAh_A**
VAh, element A
“
)3E
signed
64
0x00B3
VAh_B**
VAh, element B
“
)40
signed
64
0x00BB
Whe**
Exported Wh, all
elements.
LSB of W0SUM
)44
signed
64
0x00CB
Whe_A**
Exported Wh,
element A
“
)46
signed
64
0x00D3
Whe_B**
Exported Wh,
element B
“
)48
signed
64
0x00DB
VARhe**
Exported VARh, all
elements.
LSB of W0SUM
)4C
signed
64
0x00EB
VARhe_A**
Exported VARh,
element A
“
)4E
signed
64
0x00F3
VARhe_B**
Exported VARh,
element B
“
)50
signed
64
0x00FB
Whn
Net metered Wh, all
elements A,
LSB of W0SUM
)54
signed
64
0x010B
Whn_A*
Net metered Wh,
element A, for
autocalibration
LSB of W0SUM
)56
signed
64
0x0113
Whn_B*
Net metered Wh,
element B, for
autocalibration
“
)58
signed
64
0x011B
VARhn*
Net metered VARh,
all elements
LSB of W0SUM
)5C
signed
64
0x012B
VARhn_A*
Net metered VARh,
element A, for auto-
calibration
LSB of W0SUM
)5E
signed
64
0x0133
VARhn_B*
Net metered VARh,
element B, for auto-
calibration
“
)60
signed
64
0x013B