Operator's Manual
Second Edition • First Printing
Operating Instructions
44 QS
™
-12W • QS
™
-15W • QS
™
-20W
Part No. 1297733GT
Battery and Charger Instructions
Observe and Obey:
Do not use an external charger or booster
battery.
Charge the battery in a well-ventilated area.
Use proper AC input voltage for charging as
indicated on the charger.
Use only a Genie authorized battery and
charger.
To Charge Battery
1
Be sure the batteries are connected before
charging the batteries.
2
Open the battery compartment. The
compartment may remain closed for the entire
charging cycle.
Maintenance-free batteries
1
Connect the battery charger to a grounded AC
circuit.
2
The charger will indicate when the battery is
fully charged.
Standard Batteries
1
Remove the battery vent caps and check the
battery acid level. If necessary, add only
enough distilled water to cover the plates. Do
not overfill prior to the charge cycle.
2
Replace the battery vent caps.
3
Connect the battery charger to a grounded AC
circuit.
4
The charger will indicate when the battery is
fully charged.
5
Check the battery acid level when the charging
cycle is complete. Replenish with distilled
water to the bottom of the fill tube. Do not
overfill.