![Terex Genie Lift Guard S-40 Скачать руководство пользователя страница 157](http://html.mh-extra.com/html/terex/genie-lift-guard-s-40/genie-lift-guard-s-40_maintenance-manual_1088666157.webp)
March 2022
Maintenance Manual
Annual Maintenance Procedures
Part No. 1268489GT
S
®
Booms • Z
®
Booms
141
Note: Alternate method for achieving rated load in
the platform is to attach a hanging scale to the
bottom of the platform and apply load using a
winch or ratchet until the readout displays the
appropriate weight.
1 platform support
2 hanging scale
3 winch or ratchet
4 anchoring device
4 Add an additional 50 lbs / 23 kg of weight or
load to the platform.
Result: There is an audible alarm. Platform
Overload is indicated at the ground controls.
Result: There is no audible alarm. Platform
Overload is not indicated at the ground
controls. Calibrate the overload system. Refer
to Repair Procedure in the appropriate
Service and Repair Manual for your machine,
How to Calibrate the Platform Overload
System
.
Note: There may be a 2 second delay before the
overload indicator lights flash and the alarm
sounds.
5 Remove the weight or rated load from the
platform.
Result: There is no audible alarm. Platform
Overload is not indicated at the ground
controls.
Note: There may be an 2 second delay before the
overload indicator lights and alarm turn off.