Rev C
Instructions
Procedure
Part No. 219267
SmartLink Software Update
7
If you have any further questions regarding these
instructions or need assistance, please contact
Genie Product Support at one of the following
telephone numbers:
United States:
800-536-1800
Canada: 425-881-1800
Europe:
UK
0044 1476 584 333
France
0033 237 260 986
Germany
0049 4221 491 821
Iberica
0034 935 725 090
Italy
0039 075 941 8132
Scandinavia
0046 3157 5154
Other locations
0031 653 221 908
Middle East:
0097 143 391 800 or
0097 150 459 7937
Australia:
61 7 3456 4444
All other locations
001-425-881-1800
Test Procedure
(GS-3232 models)
1
Turn the key switch to the PCON position. Pull
out the red Emergency Stop buttons to the on
position at the GCON and PCON.
2
At the PCON, raise the platform until it stops
and the alarm sounds. Release the platform up
and function enable buttons.
3
Press and hold the function enable and
platform up buttons.
Result: The alarm continues to sound and the
platform will not raise.
Result: The alarm continues to sound and the
platform continues to raise.
Lower the platform to the stowed position and
repeat the software update procedure or
contact the Genie service department.
Tip-over hazard. An improper
operating system will
compromise machine stability
and cause the machine to tip
over, resulting in death or
serious injury.
4
Press and hold the outrigger enable and
extend buttons.
Result: The alarm continues to sound and the
outriggers do not extend. Continue to step 5.
Result: The alarm continues to sound and the
outriggers extend.
Lower the platform to the stowed position and
contact the Genie service department.
Tip-over hazard. An improper
operating system will
compromise machine stability
and cause the machine to tip
over, resulting in death or
serious injury.
DANGER