XM974-V1.0-NR
- 16 -
Clean Lamp Time
With this function you can clear the running time of the lamp. Please clear the lamp time
every time you replace the lamp.
1
.
Tap <MODE/ESC>button
,
access the main menu
,
Tap the <Up/Down>button until
“
Information
”
is displayed. Press ENTER, the display will show
“
Information
”
. Tap the
<Up/Down>button until the display will show
“
Time Information
”
. Press ENTER, the
display will show
“
Time Information
”
.
2
.
Press <Up/Down>, the display will show
“
Clean Lamp Time
”
.
3
.
At
“
Timer Password
”
menu input a correct password,
press< ENTER>, the display will show
“
Clean Lamp Time
”
,
4
.
The display will show
“
OFF
”
or
“
ON
”
.
5
.
Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu.
8.2.2 Temperature Info
Head Temperature
With this function you can display the temperature on the display board of the base (near
CMY-filter) in Celsius.
1
.
Tap <MODE/ESC>button
,
access the main menu
,
Tap the <Up/Down>button until
“
Information
”
is displayed. Press ENTER, the display will show
“
Information
”
. Tap the
<Up/Down>button until
“
Temperature Info
”
is displayed. Press ENTER, the display will
show
“
Temperature Info
”
.
2
.
Press <Up/Down>, the display will show
“
Head Temperature
”
.
3
.
Press< ENTER>, the display will show
“
Head Temperature
”
.
4
.
The display show “XXX
°
C/
°
F”.
5
.
Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu.
8.2.3 Software version
With this function, you can display the software version of the device.
1
.
Tap <MODE/ESC>button
,
access the main menu
,
Tap the <Up/Down>button until
“
Information
”
is displayed. Press ENTER, the display will show
“
Information
”
.
2
.
Press <Up/Down>, the display will show
“
Software version
”
.
3
.
Press< ENTER>, the display will show
“
Software version
”
.
4
.
The display show “Ver x.x……”.
5
.
Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu.
8.3 LAMP CONTROL
When the real temperature around the lamp is higher than the preset value, the lamp will be shut
down in 5 minutes automatically.
·
When the LCD display shows “Off”, it means the lamp must be turned on again manually;
·
When the LCD display shows “Hot”, it means the actual temperature around the lamp is still