13.  Do not allow any foreign material to intrude into the blower. 

14.  The rotation direction shall be the arrow direction on the casing. The rotation direction can be seen 

at the shaft end at counter-blower side and it is also correct, if the wind direction coincides with the 
IN and OUT indicated at the pipe connection port. Reverse rotation is allowed, although the 
performance is reduced. 

15.  Connect the power cables by using gland or electrical conduit at wiring hole of the terminal box to 

protect dust, foreign objects, water and etc. into the terminal box inside. Do not remove the unused 
rubber bushes of VFZ501

VFZ901. Do not use the rubber bushes to wiring. 

16.  Take care of edge of wiring holes at the terminal box. An 

INJURY

 is feared. 

Operation -------------------------------------------------------------------------  

Verify the following points for operating the Vacuum Pump. 

Alarm

1.  Never access or touch the rotating body (cooling fan etc.) during running. 

CATCH-IN

 or 

INJURY

 is feared. 

2.  Turn the power supply switch off in case of power failure. 

INJURY

 is feared, when the machine runs suddenly at the power restoration. 

3.  Be sure to turn the power supply switch off, in the Vacuum Pump has been stopped 

because the attached protection unit has been activated. An 

INJURY

 is feared, as the 

machine may run suddenly at the power restoration.

Alarm

4.  If any abnormality occurs, stop the operation immediately and turn the power supply 

switch off. An 

ELECTRIC SHOCK

, an 

INJURY

 or a 

FIRE

 is feared. 

5. During operation the Vacuum Pump, it becomes considerably hot. Take care not to 

touch by your hand or body. A 

BURN

 is feared. 

6.  During its operation, do not insert your finger or any other object into the opening (fan 

cover, admission and discharge ports etc.) of the Vacuum Pump. 
An

ELECTRIC SHOCK

, an 

INJURY

 or a 

FIRE

 is feared. 

7.  If the Vacuum Pump (VFZ401A and larger) is operated with the discharge side closed, 

the motor and blower temperature rises drastically and its distortion or damage after 
long time operation is feared. 

8. If the Vacuum Pump is operated at a wind flow rate not more then continuous 

operation range, the motor and blower temperature rises drastically and its distortion 
or damage is feared, if the operation is continued for along time. 

9. The temperature of the air passing through the Vacuum Pump rises. Especially it 

reaches a high temperature at a nearly closed condition. Take care not to touch it by 
your hand or body. A 

BURN

 is feared. Figure 6 shows the temperature rise. 

10. During its operation, the Vacuum Pump and discharged air will reach a considerably 

high temperature. Do not use it in a narrow closed room. A 

BURN

, a 

FIRE

 or 

DAMAGE

 is feared. (Inquire of us, if you use it in closed operation.)

Recommended gland 

VFZ101~VFZ701

  Multi hole type seal connector 

  

VFZ801, VFZ901

Seal connector

Содержание VFZ Series

Страница 1: ...ver modify the Vacuum Pump We take no responsibility for the troubles caused by repairing or modifying the product x Hand over this instruction manual surely to the end users who actually install oper...

Страница 2: ...aution items and use the machine Keep this instruction manual at the place where can be accessed by the persons who use it x The ranks for safety items are classified into alarms and cautions and desc...

Страница 3: ...wer supply cable and the lead wire for the Vacuum Pump by force An ELECTRIC SHOCK or a FIRE is feared x Restore the cover for terminal box to the original position after completion of every work Other...

Страница 4: ...or a FIRE caused by abnormal heating due to disturbed cooling is feared x Fasten the foundation bolts surely Insufficient fastening may cause an INJURY and DAMAGE due to shift of the Vacuum Pump x Nev...

Страница 5: ...edge of Impeller or key groove an ELECTRIC SHOCK or a FIRE is feared Disposal x Handle the Vacuum Pump as a general industrial waste when it is be disposed Package Opening and Product Verification Wh...

Страница 6: ...thod of the Vacuum Pump Safekeeping Take care of following points for safekeeping the Vacuum Pump or suspending its operation for a long period 1 For safekeeping in the packed Keep the Vacuum Pump in...

Страница 7: ...s feared 4 Do not place any obstacle which disturbs the ventilation around the Vacuum Pump A BURN or a FIRE caused by abnormal heating are feared due to the disturbed ventilation 5 Fasten the foundati...

Страница 8: ...ere a lot of dusts wastes or thread chips exist If inevitable clean the dusts and wastes adhered in the blower regularly A FIRE or a FAULT is feared 6 Ventilation Select a well ventilated place It she...

Страница 9: ...elf weight and external load concentrate on pipe connections Economical for high pressure and small Air flow as small pipes may be used Use large diameter pipes for long piping having many bends Pipe...

Страница 10: ...ion Alarm 4 If any abnormality occurs stop the operation immediately and turn the power supply switch off An ELECTRIC SHOCK an INJURY or a FIRE is feared 5 During operation the Vacuum Pump it becomes...

Страница 11: ...shown in the characteristics curve As the air specific weight becomes larger when the discharge side is throttled the static pressure becomes also larger 14 Remove any solid object dust thread chip w...

Страница 12: ...Oil seal Model Load side No load side Grease Model Material VFZ081PN 6201ZZ 6201ZZ Urea VFZ101PN 6202ZZ 6202ZZ Urea VCH20 30 5 Nitrile rubber VFZ201PN 6202ZZ 6202ZZ Urea SC20 30 7 Nitrile rubber VFZ30...

Страница 13: ...e resonance Vibration and noise become bigger by using inverter Stop the operation immediately if abnormal temperature rise or vibration occurs Do not use over 60Hz to protect motor burning Maximum fr...

Страница 14: ...FIRE is feared 2 If the Vacuum Pump must be abandoned as the result of investigation in a rare possibility dispose it as a general industrial waste 3 If the investigation result shows that the machin...

Страница 15: ...otate No sound Switch fault Replace or replace it Insufficient fuse capacity Replace it with lager capacity Fuse blown Short circuit in circuit Repair or replace it Power supply voltage fell Consult w...

Страница 16: ...5 5 Bolt for Terminal box conduction 2 6 Spring washer 3 22 Emblem 5 6 Packing for Terminal box cover 2 7 Silencer 1 set 3 23 Bolt for Emblem 5 7 Bolt for Terminal box cover 2 7 1 Silencer Suction si...

Страница 17: ...16 Disassembled VFZ101A VFZ301A For terminal box parts for VFZ301A See disassembled drawings of VFZ401A Motor part of VFZ101A...

Страница 18: ...17 Disassembled VFZ401A...

Страница 19: ...18 Disassembled VFZ501A VFZ601A...

Страница 20: ...19 Disassembled VFZ701A VFZ901A Motor part of VFZ801A VFZ901A...

Страница 21: ...20 Disassembled VFZ101PN VFZ301PN Motor part of VFZ101PN Silencer 3 pieces Screen plate and packing are attached to silencer of VFZ301PN...

Страница 22: ...21 Disassembled VFZ401PN...

Страница 23: ...6 2 4 3 0 1 3 1 9 5 4 7 4 6 8 13 7 17 3 VFZ601AF 2 3 3 4 11 5 13 0 12 5 21 1 27 5 9 81 3 2 4 4 2 3 3 4 11 5 13 0 12 5 18 2 23 6 VFZ101AN 0 09 0 12 0 52 0 64 0 62 5 15 6 37 2 94 0 35 0 50 0 09 0 12 0 5...

Страница 24: ...VFZ101AN 0 58 0 69 B 49 5 51 5 32 4 2 3 9 4 2 9 0 VFZ201AN 0 90 1 09 B 55 5 59 0 32 9 0 8 1 9 0 10 0 VFZ301AN 1 28 1 40 B 55 5 59 5 38 13 0 12 0 13 5 13 0 VFZ401AN 2 0 2 5 B 62 0 66 0 50 R1u 27 0 25 0...

Страница 25: ...e to improper handling or use by the User 2 due to causes of fault other then of delivered product 3 due to improper repair of modification 4 due to natural calamity or disaster which does not belong...

Страница 26: ...Head Office 230 Moriwake Miyuki cho Fukuyama city Hiroshima 720 0003 Japan Tel 81 84 955 1111 Fax 81 84 955 5777 www teral net 2016 06 E IMN 00371 000 T...

Отзывы: