PREVENTATIVE MAINTENANCE

Pump Fails 

to Start

Incorrect Voltage/Amps

Check power and correct connections.
Replace Power Cable

Replace with new protector.

Replace Motor
Replace Float Switch
Repair or Replace Control Panel
Remove foreign debris from impeller 

or casing.

Check power to ensure it corresponds to 

the nameplate

Change the power connection

Change the Impeller.
Remove debris

Remove obstruction
Replace with new cable
Reconnect after drying out.

Replace mechanical seal and oil seal

Replace with new motor.

Change the power connection
Decrease the viscosity of the liquid
Remove debris from the pump.

Check the power to make sure it 

corresponds to the nameplate.

Check if pump is completely submerged.  

Ensure the liquid temperature being 

pumped is below 30°C.

Remove foreign debris from impeller 

or casing.

Defective Cable

Clogged Impeller 

Burned Out Motor
Defective Float Switch
Bad Control Panel 

Jammed Impeller

Irregular Voltage

Tripped Motor Protector

Incorrect Rotation

Strainer is clogged 

Damaged Power Cable
Wet Cable Terminals

Burned out Motor

Irregular Voltage

Incorrect Rotation
Highly Viscous Liquid
Debris inside the pump
Damaged Bearings

Worn out mechanical seal 

causes water 

to enter.

Worn Out or Damaged 

Impeller

Non Functioning Motor 

Protector

SYMPTOM

SOLUTION

Fails to 

Deliver Full 

Output 

ELCB Trips

High 

Amperage 

Pump Starts 

but 

Immediately 

Stops

PRODUCT DISPOSAL

Properly dispose the product in accordance with your local waste disposal program.

IX

X

8

9

1.Ensure the Voltage and Amperage conform to the nameplate.

Maintenance is recommended when the insulation reading is lower 

than 10M

Replace new motor immediately when insulation is

lower than 1M .

Inspecting of Lubricant:

For pumps 1hp, the item should be checked every 3000 hours

or 12 months (whichever comes first).

For pumps 2hp, the item should be checked every 6000 hours

or 12 months (whichever comes first).

PS:Loosen the oil plug screw and check the color of the lubricant. If

      the lubricant is non-translucent, please change the mechanical seal

      and the lubricant immediately. Apply adhesive before resecuring

      the oil plug screw to strengthen the screw against leakage.

1 Replacing Lubricant:

For pumps 1hp, the item should be replaced every 4500 hours

or 24 months (whichever comes first).

For pumps 2hp, the item should be replaced every 9000 hours

or 24 months (whichever comes first).

2 change mechanical seal Inspecting and replacing the mechanical

seal Only qualified mechanics with proper tools and knowledge

should be attempting to service this pump or contact our authorized

local

1.During the typical operating cycle, it is recommended to have the

 

pump overhauled and inspected periodically.  This preventative

 

maintenance activity can extend the pump operating life cycle.

2.Please contact your authorized local dealers. 

Please record the following information for future reference:
Model Number: 
Serial Number: 
Purchase Date: 

Biennial

PROBABLE CAUSE 

Obstruction in Valves and 

Pipes.

Replace with new Bearings.

dealer in your area.

Содержание Patron SP-40

Страница 1: ...SP 40 Submersible PUMP OPERATION MANUAL Teral Inc...

Страница 2: ...event theproduct is damaged please contact your authorized localdealer or sales representative SAFETY FIRST DANGER Indicates a hazardous situation whic h if not avoided WILL result in DEATH SERIOUS IN...

Страница 3: ...event theproduct is damaged please contact your authorized localdealer or sales representative SAFETY FIRST DANGER Indicates a hazardous situation whic h if not avoided WILL result in DEATH SERIOUS IN...

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ...amperage readings are in line with the nameplate of the pump Check if the water level is normal STORAGE _ NOTICE If the pump will not be used for a long period of time wash the pump under tap water re...

Страница 9: ...amperage readings are in line with the nameplate of the pump Check if the water level is normal STORAGE _ NOTICE If the pump will not be used for a long period of time wash the pump under tap water re...

Страница 10: ...se the product in accordance with your local waste disposal program IX X 8 9 1 Ensure the Voltage and Amperage conform to the nameplate Maintenance is recommended when the insulation reading is lower...

Страница 11: ...se the product in accordance with your local waste disposal program IX X 8 9 1 Ensure the Voltage and Amperage conform to the nameplate Maintenance is recommended when the insulation reading is lower...

Страница 12: ...SP 40 Submersible PUMP OPERATION MANUAL Teral Inc...

Отзывы: