(5)  Do not put your fingers or other objects into the air intake or exhaust vents. 
(6)  Do not place any objects around the air intake or exhaust vents of the fan. 
(7)  Remove any tools and other objects from the top of the fan before operation. 
(8)  Do not operate the fan if there are any defects or faulty parts. 

1.2.3 

Precautions for maintenance and inspection 

(1)  Maintenance and inspection must be carried out only by personnel who have been trained to 

handle the fan. 

(2)  Before starting maintenance or inspection, ensure to inform the relevant personnel of the 

operation. 

(3)  Before starting the maintenance or inspection work, ensure to stop the fan and turn off the 

main power on the operation panel. 
If you carry out the maintenance or inspection work with the power on, you may suffer an 
electric shock and/or get injured by unexpected activation of the fan during the work. 

(4)  Consult Teral, Inc., or a service company before moving, repairing, or modifying the fan. 

1.3 

Location of the warning labels 

The figure below shows the locations to which each warning label should be affixed. If these 
labels become dirty and hard to read or if they are peeled off, replace with a new one. 

Warning

Follow all warnings on the labels affixed to the unit and those in the 
instruction manual. 

Nameplate

Caution 

Warning label 

c

ƕ

Ask specialized vendors for installation, 
electrical work, and repairs. 

ƕ

Only personnel authorized by the person in 
charge of machine management are 
allowed to carry out the maintenance and 
inspection work. 

ƕ

Read the instruction manual thoroughly, and
follow the instructions. 

1-2 

Содержание ALF-UII

Страница 1: ...intenance of the fan until you read this manual and understand the content Keep this manual carefully at hand so that it can be consulted anytime when operating inspecting or maintaining the fan For c...

Страница 2: ...and breakage the costs of the repairs shall be for the account of the user 1 Failures and breakage attributable to equipment that was not delivered by TERAL 2 Failures and breakage occurred after the...

Страница 3: ...tion 1 1 1 2 3 Precautions for maintenance and inspection 1 2 1 3 Location of the warning labels 1 2 2 Configuration and overview of the fan 2 1 Structure and part names of the fan 2 1 2 2 Specificati...

Страница 4: ...Do not install it anywhere with high humidity such as a bathroom 5 Do not install it in any places where toxic gases are produced from acids alkalis organic solvent paint or other substances or where...

Страница 5: ...nel If you carry out the maintenance or inspection work with the power on you may suffer an electric shock and or get injured by unexpected activation of the fan during the work 4 Consult Teral Inc or...

Страница 6: ...ture and part names of the fan No Part name c Silencer box d Fan casing e Impeller f Fan air intake g Motor h Motor lead wire i Ground terminal Ground wire j Lifting harness k Intake companion flange...

Страница 7: ...t under any conditions other than those provided in the specifications Failure to observe this may cause an electric shock fire and or product failure 1 Standard specifications Clean air Air 0qC to 40...

Страница 8: ...s not form during storage before installation In particular take measures to protect the motor section against the entry of rainwater and dust for example by covering them with a vinyl sheet 2 Store t...

Страница 9: ...t 2 Before connecting the ducts check inside the ducts and fan and remove any foreign matter such as waste cloth and tools Warning Be sure to install a protective wire mesh on any open air intakes of...

Страница 10: ...round wires for telephone Warning It is prohibited by law to perform incomplete grounding work which exposes personnel to a great danger 4 The wire connection of the ALFII U 20M differs between 50 Hz...

Страница 11: ...ure to turn off the main power before changing the wiring of the fan 4 1 2 Checking the fan system 1 Check that no water collects in the fan and that no foreign objects or materials such as tools have...

Страница 12: ...f flowing air is lower than the room temperature 5 2 Precautions during the operation Warning In the event of a power failure be sure to turn off the main power Otherwise when the power is restored th...

Страница 13: ...ssibly made by contact with the rotor stop the operation immediately 6 2 Periodic inspection Warning Before carrying out the inspection of the fan be sure to turn off the main power Otherwise the fan...

Страница 14: ...ns Poor piping 9 9 9 Inspect and repair the duct piping Excessive duct resistance 9 9 9 Review the duct piping Insufficient duct resistance 9 Review the duct piping Insufficient number of revolutions...