15.

 

Environment information  

This equipment is intended for use in a Pollution Degree 2 environment, at altitudes up to 2000 

meters. When the controller is a part of a system, the other elements of the system shall comply 

with the EMC requirements and shall be intended for use in the same ambient conditions. 

16.

 

Safety 

This device must not be used for medical, life-saving purposes or for any purpose where its failure 

could cause serious injury or the loss of life. 
To reduce the risk of fire, only flexible stranded wire, with cross section 0.5mm² or larger for wiring 

of digital and analog inputs and relay output of the device should be used.  
To avoid electric shock and fire hazard, do not expose this product to liquids, rain, or moisture. 

Objects filled with liquids, such as vases, should not be placed on this device. 
There is a risk of overheating (damage) of the controller if recommended free spaces to adjacent 

devices are not ensured. A joint part with external component shall have space for 

attachment/removal of the cable after installation. 
Teracom does not guarantee successful operation of the product if the product was used under 

conditions deviating from the product specifications. 

To ensure that the device works correctly follow the steps below: 

 

ensure that the device is installed correctly, refer this user manual; 

 

log into the devices via browser program; 

 

make proper setup; 

 

set up the digital inputs to work in “dry contact” mode; 

 

short the “Din1” and “GND”; 

 

install sensor TSH1XX or TST1XX on the 1-Wire bus; 

 

go to “Monitoring page” of WEB interface –  proper parameters value should be 

displayed at the same time flashing “STS” led should indicate the proper operation. 

If the equipment is used in a manner not specified by the manufacturer, the protection provided 

by the equipment may be impaired. 
In no event will Teracom Ltd. be responsible or liable for indirect or consequential damages 

resulting from the use or application of this equipment. 

17.

 

Maintenance 

Upon completion of any service or repairs to the device or once per year, safety check must be 

performed to determine that this product is in proper operating condition. Clean the device only 

with dry cloth. Do not use a liquid cleaner or an aerosol cleaner. Do not use a magnetic/static 

cleaning device (dust remover) or any kind of abrasive materials to clean the device. 

 

 

Содержание TCW122B-CM

Страница 1: ......

Страница 2: ...remote control and monitoring 2 Features Password protected web based configuration and control 2 digital inputs with dry contact and logic level modes 2 analog inputs with 0 to 60VDC range 2 relays w...

Страница 3: ...ed load 1 Wire interface Output voltage VW 5 3 0 2 VDC Maximum output current VW 0 2 A Internal FLASH memory Endurance 100 000 cycles Every relay status and settings change is a memory cycle 4 Powerin...

Страница 4: ...iguring via a web browser TCW122B CM can be wall or flat not flammable surface mounted in a clean and dry location room Ventilation is recommended for installations where the ambient air temperature i...

Страница 5: ...pening the Login page authorization data must be entered by default username admin password admin It is recommended to change the username and password to prevent unauthorized access to the controller...

Страница 6: ...every 30mS The change of input status is considered valid if the same value is read in seven consecutive samples 8 3 Network Setup page The Network parameters are set on this page The following param...

Страница 7: ...be changed in the Web Access section Setting the authentication to disabled will provide access to monitoring page without entering username and password The HTTP port can be changed also in this sec...

Страница 8: ...ion 8 5 I O setup page I O settings can be made here For temperature humidity and analog value MIN MAX and HYSTERESIS values can be set These values define the thresholds for all monitored parameters...

Страница 9: ...ters are set for Sensor1 Min 19 Max 100 and Hys 0 5 When the controller is switched on Relay1 is immediately activated because the monitored temperature is out of range This switches the heater on The...

Страница 10: ...to 253 seconds By default relay state changes via the WEB interface are memorized in a non volatile memory After the power on the relay goes in its last state before the power down If the Save relay...

Страница 11: ...ular installation Teracom Ltd cannot assume responsibility or liability for actual use based on the examples and diagrams 9 1 Temperature and humidity control TCW122B CM supports 1 Wire temperature an...

Страница 12: ...registered trademark of Maxim Integrated Products Inc It is designed to connect several sensors over a short wiring The bus carries power and a single data wire It is not suitable for long distances...

Страница 13: ...ice hostname String SIZE 0 38 11 3 Setup snmpSetup OID Name Access Description Syntax x 2 4 1 0 snmpConfiguration read write SNMP Configuration INTEGER disabled 0 enabled 1 x 2 4 2 0 trapEnabled read...

Страница 14: ...GER 0 1000 x 2 7 1 3 0 voltage1Hyst read write Voltage1 hysteresis INTEGER 0 1000 x 2 7 1 4 0 voltage1Action read write Voltage1 action INTEGER noAction 0 sendMail 1 x 2 7 1 5 0 voltage1Description re...

Страница 15: ...1 x 3 5 0 relay2State read write Relay2 state INTEGER off 0 on 1 x 3 6 0 relay2Pulse read write Relay2 pulse INTEGER off 0 on 1 x 3 7 0 voltage1x10Int read only Voltage1 x10 in integer format INTEGER...

Страница 16: ...at of the command is shown in the table below XML HTTP API authentication Format enabled http device ip address status xml a uuuu pppp disabled http device ip address status xml Where uuuu is username...

Страница 17: ...ng off the power supply will damage the device For some updates factory default settings procedure is mandatory 14 Factory default settings TCW122B CM can be restored to its original factory default s...

Страница 18: ...acom does not guarantee successful operation of the product if the product was used under conditions deviating from the product specifications To ensure that the device works correctly follow the step...

Страница 19: ...TCW122B CM_R4 5 March 2019 Page 18 Appendix A Fig 1 Fig 2...

Страница 20: ...TCW122B CM_R4 5 March 2019 Page 19...

Отзывы: