11.  Environment information

 

This equipment is intended for use in a Pollution Degree 2 environment, at altitudes up to 

2000 meters. When the module is a part of a system, the other elements of the system shall comply 

with the EMC requirements and shall be intended for use in the same ambient conditions.

12. Safety

 

This device must not be used for medical, lifesaving purposes, or for any purpose where its 

failure could cause serious injury or the loss of life.

 

To reduce the risk of fire, only flexible stranded wire, with cross-section 0.5mm² or larger for 

wiring of digital and analog inputs and relay output of the device should be used. 

To avoid electric shock and fire hazard, do not expose this product to liquids, rain, or moisture. 

Objects filled with liquids, such as vases, should not be placed on this device

.

 

There  is  a  risk  of  overheating  (damage)  of  the  module,  if  recommended  free  spaces  to 

adjacent devices are not ensured. The joint part with the external component shall have space for 

attachment/removal of the cable after installation.

Teracom does not guarantee the successful operation of the product if the product was used under 

conditions deviating from the product specifications

.

 

To ensure that the device works correctly follow the steps below:

•  ensure that the device is installed correctly, refer to this document;

•  log into the devices via browser program;

•  make proper setup;

•  set up the digital inputs to work in “dry contact” mode;

•  short the “Din1” and “GND”;

•  install sensor TSH2XX or TST1XX on the 1-Wire bus;

•  go  to  “Monitoring  page”  of  WEB  interface  –  proper  parameters  value  should  be 

displayed;

•  go to “Setup-> SMS/Mail” menu and set the Master number. After saving the number, 

press “send test SMS” button. The master should receive a confirmation SMS message.

 

If  the  equipment  is  used  in  a  manner  not  specified  by  the  manufacturer,  the  protection 

provided by the equipment may be impaired. In no event will Teracom Ltd. be responsible or liable 

for indirect or consequential damages resulting from the use or application of this equipment.

13. Maintenance

 

Upon completion of any service or repairs to the device or once per year, a safety check must 

be performed to determine that this product is in proper operating condition. Clean the device only 

with a dry cloth. Do not use a liquid cleaner or an aerosol cleaner. Do not use a magnetic/static 

cleaning device (dust remover) or any kind of abrasive material to clean the device.

14.  Package content

 

The product package includes:

• TCG140-4;

• Multi-band antenna - 698 to 960 and 1710 to 2690MHz;

• Four spacers/bumpers;

• RS-485 terminator;

• Quick start guide.

Содержание TCG140-4

Страница 1: ...www teracomsystems com TCG140 4 LTE universal IO module Revision 1 0 February 2021 QUICK START GUIDE ...

Страница 2: ... 158 x 119 x 34 Operating temperature range C 20 to 55 Operating relative humidity range RH 5 to 85 non condensing Bands TCG140 4e variant 4G LTE B1 B3 B7 B8 B20 B28 3G 2G B1 B8 900 1800 Bands TCG140 4a variant 4G LTE B2 B4 B5 B12 B13 B25 B26 3G 2G B2 B4 B5 Not supported SIM card size Micro Minimum high level input voltage for digital inputs VDC 2 5 Maximum low level input voltage for digital inpu...

Страница 3: ...n 21 and 40 SIG flashes 3 times in a period of 2S signal strength is between 41 and 60 SIG flashes 4 times in a period of 2S signal strength is between 61 and 80 SIG is solid ON signal strength is between 81 and 100 Error message in case of error after initialization SIG will stay solid OFF STA will flash showing the type of error STA flashes ones for 1S master phone number is not set STA flashes ...

Страница 4: ...IM card holder 6 Connectors The device has the following connectors 3 7 8 9 10 11 12 Connector 1 Power 2 1x5 5mm connector central positive Connector 2 1 Wire interface Connector 3 RS 485 interface Pin Description Corresponding UTP wires color Pin1 GND most left White Brown Pin2 GND White Green Pin3 1 Wire data Green Pin4 1 Wire GND White Orange Pin5 1 Wire VDD Orange Pin6 1 Wire VDD most right Br...

Страница 5: ...led automatically it must be installed manually The driver can be downloaded from the TCG140 4 product page at www teracomsystems com After successful driver installation the device will be recognized as Mass storage the following window appears on the screen The only file stored on the mass storage is a tool called TConfig This tool enables communication between the TCG140 4 and PC After starting...

Страница 6: ... procedure takes about 2 minutes Once the update is complete the browser will be redirected to the monitoring page Attention Don t turn off the power supply during the update Turning off the power supply will damage the device 9 2 Firmware update over the Internet To update the device over the Internet follow the steps below Upload the update file cod extension on public HTTP server Send firmware ...

Страница 7: ...uct specifications To ensure that the device works correctly follow the steps below ensure that the device is installed correctly refer to this document log into the devices via browser program make proper setup set up the digital inputs to work in dry contact mode short the Din1 and GND install sensor TSH2XX or TST1XX on the 1 Wire bus go to Monitoring page of WEB interface proper parameters valu...

Страница 8: ... 35 EU The above product is in conformity with the following standards EN 55032 2015 EN 55032 2015 AC 2016 07 EN 55032 2015 A11 2020 EN 55024 2010 EN 55024 2010 A1 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 61000 3 3 2013 A1 2019 EN 301 511 V 9 0 2 EN 62368 1 2014 EN 62368 1 2014 AC1 3 2015 EN 62368 1 2014 A11 2017 EN 62368 1 2014 AC 2017 03 2017 Place Ruse Bulgaria Signature Name Ognyan Dimitrov...

Отзывы: