![TER SRL Multi Synergic 280 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/ter-srl/multi-synergic-280/multi-synergic-280_instruction-manual_1088149009.webp)
Instruction Manual
Multi Synergic 280 - Multi Synergic 350 - Multi Synergic 400F - Multi Synergic 500- Multi Synergic 500F and Accessories
9
13. SPECIAL FUNCTIONS
RESET TO DEFAULT SETTING FUNCTION (default working parameters)
Press for 10 seconds the switch SW1 until the display show the menu load default
working parameters. Confirm YES by the switch under display yes.
LOCK JOBS FUNCTION
This function is activated only if insert the digital torch.
LOCK JOBS : press SW2 for 5 seconds.
UN LOCK JOBS : press SW2 for 10 seconds.
With LOCK JOBS is it only possible change the JOBS parameters.
All other setting are locked. If it press a switch or it moved a knob the display shows
“LOCK JOB” function activated.
SEE SET / SEE REAL FUNCTION
Set MANUAL MMA mode, set current 123A (in to display 1), set arcforce 45 (in to
dipslay 2).
Press SW3 for 3 seconds If is active the function see set, and you want activate the
function see real.
Press SW3 for 3 seconds If is active the function see real, and you want activate the
function see set.
In SEE SET mode during the welding the display show setting parameters.
In SEE REAL mode during the welding the display show real working parameters :
output current and output voltage.
SEE POWER MODULE TEMPERATUR FUNCTION
Set MANUAL MMA mode, set current 123A (in to display 1), set arcforce 50 (in to
dipslay 2).
Press SW3 for 3 seconds, unless the display show the temperatur read from the NTC
in the power module.
DISPLAY SOFTWARE VERSION FUNCTION OF ROUCH PANEL
Set MANUAL MMA mode, set current 123A (in to display 1), set arcforce 55 (in
to dipslay 2).
Press SW3 for 3 seconds, unless the display show the touch pannel software
version, and other parameter.
INC FUNCTION.
press torch switch for 3 seconds untill display show, INC and the motor stops.
Release and re-press the torch switch, the wire comes out without gas at speeds
up to 10 m / min.
SPEED WIRE CALIBRATION
press torch switch for 3 seconds, untill display show INC and the motor stops
release the torch switch and press SW4 button 3 times, untill display show SPD
SET, press torch switch again, the wire exits without gas first at three m/min and
then to 10 m/min, then stops. This operation serves to control board to calibrate
the motor speed and must be performed to load, with the wire inserted in the
sheath.