8
Operation
Danger Risk of explosion!
First read the following instructions for switching on /
lighting and all warning and safety information before
lighting the gas fireplace.
– Check the gas fireplace for cracks, cuts, or other damage
before using it.
– Do not use the gas fireplace if the gas hose is damaged or
porous.
ignition system
1. Set the rotary switch to start. .
2. Open the gas bottle valve.
3. Press and hold the control dial for approx. 30 seconds.
4. Operate the piezo igniter (several times if necessary) until
the pilot flame burns. When the burner has ignited, you can
let go of the piezo igniter.
5. Press and hold the control dial for another 30 seconds.
6. You can set the power level by pressing and turning counter-
clockwise.
important! If the burner does not ignite, turn off the cylinder
valve on the gas cylinder. Wait 5 minutes and try again.
7. To switch off the gas fireplace, turn off the gas bottle valve.
Maintenance and cleaning
Danger Risk of burning!
Let the grill cool down completely before cleaning.
Danger Health risk!
Do not use any decolorants or thinners to remove
stains. These are harmful to health and must not
come into contact with food.
Attention Risk of damage!
Do not use any strong or grinding solvents or abra-
sive pads, since these can attack the surfaces and
leave behind scrape marks.
• Clean the surfaces with a damp cloth.
• Use a soft, clean cloth for drying.
• If you are not going to use the device for a longer period of
time, place it in a dry, dust-free place. Cover it with the sup-
plied hood after it has cooled down completely so that it is
protected from contamination, damage and malfunction.
troubleshooting
problem
possible cause
suggested solution
Burner won’t ignite.
– LP gas bottle is empty
– Defective regulator
– Blockage in burner
– Blockage in the gas noz-
zles or in the gas hose
– Electrode cable loose or
separated from electrode
or ignition unit
– Electrode or cable defec-
tive
– Defective ignition switch
– Replace with full LP
gas bottle
– Get the regulator tested
or replace it
– Cleaning the burner
– Clean the gas nozzles
and gas hose
– Reconnect the cable
– Replace the electrode
or cable
– Replace the ignition
switch
Burner does not
ignite with match
– LP gas bottle is empty
– Defective regulator
– Blockage in burner
– Blockage in the gas noz-
zles or in the gas hose
– Replace with full LP
gas bottle
– Get the regulator tested
or replace it
– Cleaning the burner
– Clean the gas nozzles
and gas hose
Small flame or
flame blowback
(fire in burner tube
or a roaring noise
can be heard)
– LP gas bottle is too small
– Blockage in burner
– Blockage in the gas noz-
zles or in the gas hose
– Wind in gas fireplace area
is too strong
– Use larger gas bottle
– Cleaning the burner
– Clean the gas nozzles
and gas hose
– Position the gas
fireplace in an area pro-
tected from the wind
Temperature
regulator difficult
to turn
– Gas valve blocked
– Replace gas valve
disposal
The packaging is made from environmentally friendly
materials, which you can dispose of at your local recy-
cling points.
Do not under any circumstance dispose of the fireplace
in normal household waste! Dispose of it at an approved
disposal business or at your community disposal facility.
Respect the currently valid regulations. If in doubt, get in
touch with your disposal facility.